My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 1:02:11 PM
Creation date
7/31/2020 2:24:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRESSURIZED PIPING LEAK DETECTION CERTIFICATION SHEET <br /> CCi RS <br /> ItVA��� <br /> 20 SOLUTIONS DEL. IVEFED <br /> Date : 8-6-2019 CERS I . D . # 10180781 <br /> Location : United Pacific # 5447 Contact : Tom M . Robins <br /> 1469 East Hammer Lane <br /> Stockton 95210 Telephone : (310) 323-3992 ; 2012 <br /> SUMP # #7-8 #7-8 #7-8 #7-8 <br /> PRODUCT T1 91 T2 89 T3 87 T4 Diesel <br /> LD TYPE Mechanical , W PLLD , ( P) LLD M M M M <br /> LD MANUFACTURER VMI VMI VMI VMI <br /> LD MODEL LD 2000 LD 2000 LD 2000 LD 2000 <br /> LD SERIAL NUMBER 15031247 09041087 19011018 07081287 <br /> SUMP CONDITION Good Good Good Good <br /> RESILIENCY 150 ml 150 ml 200 ml 150 ml <br /> OPERATING PRESSURE 28psi 28psi 30psi 28 psi <br /> OPENING TIME 3 sec 3 sec 4 sec 4 sec <br /> METERING PRESSURE 10 psi 10 psi 10 psi 10 psi <br /> FUNCTIONAL ELEMENT HOLDING PRESSURE 18 psi 18 psi 18 psi 18 psi <br /> LEAK RATE LD DETECTED 3 Gph 3 Gph 3 Gph 3 Gph <br /> DOES LD DETECT 3 GPH LEAK RATE? Yes Yes Yes Yes <br /> DOES VEEDER- ROOT CONSOLE ALARM ? N/A N/A N/A N /A <br /> LD PASS OR FAIL? Pass Pass Pass Pass <br /> Comments : <br /> T3 87 LD Failed 3GPH test, Leak detector was replaced and tested and passed . <br /> Technician : Garrett Warren Contractor Lic . # 803616 <br /> Signature : <br /> GPH = Gallons per hour, Y = Yes, N = No, NA = Not applicable, VPH = Vacuum/Pressure/Hydrostatic, ID = Identification <br />
The URL can be used to link to this page
Your browser does not support the video tag.