Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑Repair Inspection 9 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10151579 2/8/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Tracy USD Service Center <br /> Business Site Address City ZIP Code <br /> 1975 W. Lowell Ave Tracy 95376 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Andrew Bagley (209) 367-4800 <br /> Contractor 1 Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 774802 8012449 12/24/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> OPW. Emco-Wheaton <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑Manufacturer Guidelines(Specify): <br /> Used: <br /> Q Industry Code or Engineering Standard(Specify):PEI/RP 1200-17 <br /> ANk <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. ` #of Attacbed;Pages r <br /> TANK ID:(By tank number,stored product,etc.) 252102/87/10K <br /> What is the tank inside diameter?(Inches) Cis r <br /> Is the rill piping secondarily contained? ❑x Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Is the vent piping secondarily contained? ❑x Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Overfill Prevention Equipment Manufacturer(s) p w <br /> What Is the overfill prevention equipment response ❑x Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) El Restricts Flow E]❑Restricts Flow Restricts Flow ❑Restricts Flow <br /> ❑AN Alarm ❑AN Alarm ❑AN Alarm ❑AN Alarm <br /> Are flow restrictors Installed on vent piping? ❑Yes ❑X No ❑Yes ❑No ❑Yes <br /> ❑No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(inches from bottom of tank.) 85tt <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 93.6% <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results Oxxl Pass ❑Fail I ❑Pass ❑Fail 1 ❑Pass ❑Fail ❑Pala ❑Fail <br /> V. COMMENTS <br /> Any items marked"Fail"must be explained in this section. Any additional comments may also be provided here. <br /> This is a re-inspection.The valve was originally inspected on 10/12/2018, however, the valve/tube was rusted and could <br /> not be removed for inpection and was subsequently noted as a"FAIL".A re-attempt to remove the valve for inspection <br /> and testing on 02/08/2019 was successful. The valve will shut-off flow at 93.6%of tank capacity and is considered a" <br /> PASS". <br /> VI. CERTIFICA i ION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected In accordance with California Code of Regulatlons,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all th nformation contained herein is accurate. <br /> UST Service Technician Signature <br /> 5 c _ Ga o�/f y <br /> !f the facility has more components than—this f accom dates,add ies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=Intematiorial Code Council,AN=Audble and Vmol <br />