My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 10:38:59 AM
Creation date
8/3/2020 11:39:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type ofActlon M Installation Inspection ❑ Repair Inspection ❑ 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181419 04/09/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As.) <br /> San Joaquin County Sheriffs Operations Ctr #1 <br /> Business Site Address CityZIP Code <br /> 7000 N Michael Canils Blvd French Camp 95231 <br /> Il. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # M <br /> Eric Mol card 209 367 - 4800 E <br /> Contractorrrank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 774802 18881020 02/25/2021 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> OPW <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used : ❑ Manufacturer Guidelines (Specify) _ <br /> ® Industry Code or Engineering Standard (Specify) PEURPA 200- 17 <br /> ❑ Engineered Method (Specify) <br /> Attach the Inspection procedures and all documentation required to determine the results. # of Attached Pages: <br /> Tank ID: (By tank number, stored product, etc.) 3701 /87/25k 3702/DsU6k <br /> off <br /> What Is the tank inside diameter? (Inches) / V t f q <br /> Is the fill piping secondarily contained? ❑ Yes ® No ❑ Yes ® No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes ® No ❑ Yes ® No ❑ Yes ❑ No ❑ Yes ❑ No <br /> OPW OPW <br /> Overfill Prevention Equipment Manufacturers) <br /> 71 SO rEIAfVAlarm <br /> What Is the overfill prevention equipment 0 Shuts Off Flow ts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> response when activated? ❑ Restricts Flow tricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) ❑ / / Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes ® No ❑ Yes ® No ❑ Yes ❑ No ❑ Yes ❑ No <br /> At what level in the tank Is the overfill prevention 1 l <br /> set to activate? (Inches from bottom of tank.) <br /> What Is the percent capacity of the tank at which G L , CS j 9 <br /> the overfill prevention equipment activates? 1 �1 6 a G <br /> Is the overfill prevention in proper operating ® Yes ® Yes ❑ Yes ❑ Yes <br /> condition to respond when the substance ❑ No ❑ No ❑ No ❑ No <br /> reaches the appropriate level? (Specify to section V.) (Specify In section V.) (Specify In section V.) (Specify in section V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fall I ® Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> All items marked 'Fail' must be explained In this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was Inspected in accordance with Califomia Code of Regulations, title 23, division 3, <br /> chapter 18, section 2837.2 and all the Information con ' ed herein Is accurate. <br /> UST Service Technician Signature <br /> ff the facility has more components theifthis form accommodates, additional copies of this page may be attached. <br /> CERS = Cal*rniaEN xdmnmentaliRexwftSysbenn, W = ldendfio<tion, IAT = UndaMutudedorWetank, ICC = lntenstiDrW Code Council, AIV = AudIbiexndviimW <br />
The URL can be used to link to this page