Laserfiche WebLink
Installation Guide; Residential AdvanTex® Systems <br /> The AdvanTee Treatment System has five main functional units: <br /> 1. Control Panel <br /> 2. AdvanTex�Filter Pod <br /> 3. Recirculating Splitter Valve <br /> 4. Biotube®Pumping Package <br /> 5. Processing Tank <br /> i_ <br /> fi <br /> tt <br /> r.. <br /> i <br /> Mode 3 shown <br /> Raw sewage enters the two-compartment processing tank through its inlet tee. In the first compartment,the raw <br /> sewage separates into three distinct zones: a scum layer, a sludge layer, and a clear layer. Holes in the tank's <br /> baffle wall allow effluent from the clear layer to flow into the second compartment of the tank.The BiotubeO <br /> pump package in the second compartment pumps filtered effluent to a distribution manifold m the AdvanTex pod <br /> Effluent percolates down through the textile media and is collected in the bottom of the filter basin.The treated <br /> effluent flows out of the filter basin through a 2" diameter pipe that returns the treated effluent to the recirculating <br /> splitter valve(RSV). The RSV automatically splits the return flow between the processing tank and the final <br /> discharge.The RSV also controls the liquid level within the processing tank. During extended periods of no flow, <br /> 100%of the treated effluent is returned to the processing tank. <br /> The operation of the pump in the second compartment is controlled by a programmable timer in the control panel, <br /> which allows the pump to dose the filter for short periods(usually a half-minute or less),typically 72 times a day. <br /> This frequent"microdosing,"which optimizes the treatment process, occurs 24 hours a day,to maintain the proper <br /> biological environment. <br /> NIM-ATX-AX-1 ®2004 prance Systems'Inc. <br /> Rev 3.1.OW <br /> r` <br />