My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
401
>
4200 – Liquid Waste Program
>
PR0526172
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2020 7:50:28 PM
Creation date
8/5/2020 10:00:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0526172
PE
4242
FACILITY_ID
FA0017710
FACILITY_NAME
ANKA NORTHSTAR
STREET_NUMBER
401
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
MANTECA
Zip
95336
APN
24130052
CURRENT_STATUS
01
SITE_LOCATION
401 S AIRPORT WAY
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\4200 - Liquid Waste\A\AIRPORT WAY\401\PR0526172\INSPECT CORRESPOND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
InstafatiAn Guth.: end4lAdvanTex" Systems • <br /> This worksheet is intended to help you determine appropriate start-up timer settings(Pump ON,pump OFF) for a <br /> single-pod AX20 system.Typical valves and ranges are provided for each parameter.As you gain experience with a <br /> system,you may conclude that you need to make adjustments, sometimes significant ones.If you have any questions <br /> or if your values fall outside the desired ranges on this worksheet,contact your Dealer. <br /> Number of people 3 Range of 2 to 8 people. <br /> Water usage per person 50 gpd Typical daily average is 50 gallons per person. <br /> Qi Actual daily flow(total) 150 gpd (Number of people)x(water usage per person). <br /> Rb Return recirculation ratio 3: 1 You can adjust this ratio(return flow ta:forward flow)up or <br /> down depending on system performance.(Range of 2 to 6,) <br /> Total daily flow to AX20 600 gpd (Actual daily flow)x(return recirculation ratio+ 1). Must be s 3000 <br /> gpd.Actual flow should not exceed 500 gpd. <br /> (500 gpd x 6:1 Rb=3000 gpd) <br /> Qd Actual pump dose rate 33.3 gpm Oetarmine this value by field-testing or by using Orenco's <br /> PumpSelectr"r.Start at the low and. <br /> Td Pump ON cycle time(dose) 0.25 min Select a value between 0.25 minutes(15 seconds)and 0.75 minutes <br /> 05 seconds). <br /> Tr Pump OFF cycle time(rest) 19.74 min See Pump OFF equation below. <br /> Ptugging in the above values and'rounding,we get the following: <br /> 1440 • Td • Qd 1440• 0.25 • 33.3 <br /> T, = —Td T, = »- 0.25. = 19.74=19.75 <br /> (N+1) • Qi (3 +1) . 150 <br /> After you determine your Pump ON and Pump OFF times,double checkto make sure your start-up settings fall within the cycle <br /> time(CT)range,below.If they don't,make adjustments per the"Note." <br /> 4 <br /> CT Cycle time 20.0 min Try not to exceed 30 min per cycle to avoid drying out the <br /> treatment media.If value exceeds 30 min,decrease ON time. <br /> (If this is at the minimum,increase recirc ratio.) <br /> Pump cycles per day 72 cycles 1440 min/day+(OFF cycle time.*ON cycle time). Must not exceed <br /> the pump's maximum rated cycles per day of 300 cycles per day. <br /> Gallons per cycle 8.3 gal With 68 orifices and using the Td range recommended above, <br /> you will maintain the recommended 0.12 to 0.25 gallons <br /> per orifice per dose. <br /> Number of People Time ON(seconds) Time 011e(minutes) NOTES: <br /> 2 15 29.75 -Assumes water usage of 50 gallons per person <br /> 3 15 19.75 per day and a return recirculation ratio of 3: 1. <br /> 4 30 29.75 -Override OFF cycle time is set at one-half of the <br /> 5 30 23.75 OFF cycle time. Override ON cycle time is setthe <br /> 6 30 19.15 same as the ON cycle time. <br /> ®2004 orenao Systems*Inc. Nlil-IIrX.lUL-1 <br /> Aer8.i.001At. <br />
The URL can be used to link to this page
Your browser does not support the video tag.