�ADVANTEXO O&M <br /> MANUAL <br /> Routine Cleaning & Maintenance Procedures <br /> Orenco Systems•requires regular inspection and 2 Check voltages and motor run amps and <br /> maintenance of AdvanTee Treatment Systems record them on the Field Maintenance Report <br /> as a condition of purchase.All activities are to Form.If the voltage drop exceeds National <br /> be performed three-to-six months after system Electric Code(NEC)requirements,have an <br /> start-up;and an annual field-service inspection, electrician verify the service line and check pump <br /> including sampling,is to be scheduled in late windings. <br /> spring or in early summer. For AXN systems, <br /> there is to be a minimum of four inspections <br /> during the fust two years,and then annual <br /> inspections thereafter. ; <br /> Following is a list of the routine cleaning and <br /> maintenance procedures we recommend or <br /> require. Failure to provide required maintenance ' <br /> will void the AdvanTee Treatment System <br /> warranty. .. <br /> Copies of inspection and maintenance reports, # <br /> along with any additional documentation,must " <br /> be forwarded to and retained by the Authorized - : <br /> AdvanTee Treatment System Dealer who sold <br /> the system.If there is no Dealer,then the docu- 3 Verify that the programmable timer settings 7 ' <br /> mentation must be forwarded to Orenco for all pumps are correct.With MVP panels,you <br /> Systems,Inc.,814 Airway Avenue,Sutherlin, can check timer settings using the digital timer's <br /> OR 97479,ATTN:Systems Engineering. function keys and large LCD display.With <br /> Control Panel/Pumps/Alarms <br /> VeriComm®panels,(shown here),you can check <br /> Eimer settings online or at the panel,using a lap- <br /> WARNINO.Only qualifiedlcerd ied elects- top computer or small,hand-held device.If the <br /> clans or service providers should perform timer settings have been changed,the current set- <br /> maintenance on electrical equipment ting and date of change should be written on . <br /> your Timer Setting Instructions and Record of <br /> 1 Check pump operations.Place the MOA System Facts,at the back of this Manual.Place <br /> switch(Manual,Off,Automatic) to Manual and the date and your initials by the recorded change. <br /> make sure the pump runs.Then switch back to <br /> Automatic and continue to check the automatic <br /> operation of the alarm floats,the recirc timer on <br /> the floats,the discharge timer on/off,and timer <br /> overrides.Refer to the installation,operation,and <br /> setting instructions for the control panel that <br /> comes with the system.A set of instructions is <br /> stored in aplastic p lastiket on the inside of the <br /> p �+ma•' c I <br /> panel door.* <br /> NOTE <br /> AUTO Be sure to ret <br /> the MOA <br /> OFF switch back *If the instructions are miuing,you can obtain <br /> to Auto after another set fiom Orenco's online Document <br /> MAN testsng. Library, at www orenco.com, or by calling Orenco <br /> at 1-800-348-9843, or by calling your local <br /> Advan Tex Dealer. <br />