My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
401
>
4200 – Liquid Waste Program
>
PR0526172
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2020 7:50:28 PM
Creation date
8/5/2020 10:00:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0526172
PE
4242
FACILITY_ID
FA0017710
FACILITY_NAME
ANKA NORTHSTAR
STREET_NUMBER
401
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
MANTECA
Zip
95336
APN
24130052
CURRENT_STATUS
01
SITE_LOCATION
401 S AIRPORT WAY
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\4200 - Liquid Waste\A\AIRPORT WAY\401\PR0526172\INSPECT CORRESPOND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADVANTEX• O&M MANUAL. <br /> • Check to ensure retire ratio isdt too high <br /> • Check to see if influent flows are below normal <br /> • If influent flows are below normal or retire <br /> ratio is too high,reduce recirc ratio <br /> Troubleshooting Biotube• Filter : <br /> Clogging <br /> If a visual inspection of the Biotube•filter for <br /> biomass build-up shows the need for cleaning ' <br /> more often than once every 1-2 years(which <br /> is typical for recirculating systems),try the <br /> following- If the system user cant identify the probable <br /> source,try the following: <br /> • Verify the pump isnt running too long <br /> (typically 3 cycles/hour) • Sample/test effluent for BODS and Grease <br /> • Ensure the retire ratio isn't too high &Oil <br /> • Sample/test at all process steps, including <br /> • Verify normal DO levels;if high,reduce influent(if possible) <br /> retire ratio <br /> • Label, date,and photograph all samples <br /> • Check for below normal influent flows <br /> • Use standard glass beakers and set samples in <br /> • Check influent Grease&Oil and TSS;if front of a common,uniform background, <br /> excessive,a review of component sizes may <br /> be required when photographing <br /> • Check biomat accumulation at AdvanTee <br /> Filter <br /> " - • Note if biomat is yellowish and wax-like or <br /> lard-like.If so,scrape biomat sample for <br /> analysis: <br /> —Photograph/document biomat sample <br /> —Send to lab with effluent samples <br /> Note:Excessive Grease&Oil(>25 mg/L)is <br /> typically a design and management concern <br /> with commercial applications. <br /> Troubleshooting Foam <br /> Troubleshooting Oily Film <br /> Foam indicates that microbes are producing <br /> All signs of oil or grease anywhere in the system excessive gas byproducts.Foam rarely occurs in <br /> (in the tank,in the vault,on the effluent or tex- packed bed filters(and AdvanTex•is a packed <br /> tile filter)must be investigated.Ask the system bed filter).If foam is present: <br /> user to identify the probable source: <br /> - • Verify the pump isn't running too long <br /> • Recent change of car oil? • Ensure the retire ratio iset too high <br /> • Canning meat or poultry? . Ask residents about detergent use <br /> • Excessive use of garbage disposal? <br /> • Excessive use of bath or mineral oils? <br /> Ute•tub?) <br /> • Excessive use of detergents? <br />
The URL can be used to link to this page
Your browser does not support the video tag.