Field Sampling Report Form <br /> Date: <br /> Inspector: <br /> Address: <br /> System Type., <br /> The following effluent tests can be easily and routinely performed in the field.Perform annually,or as frequently <br /> as necessary per the methodology indicated.For AXN systems,there is to be a minimum of four sampling <br /> events the first two years and then annual sampling thereafter.Record your results/observations in the space <br /> provided: <br /> Parameter Methodology Typical Field Observations Pre-Test Lab Concurrence <br /> Clarity Visual, Clear(15t JTUs or <br /> NTUs) <br /> Odor Sniff' Non-offensive(no <br /> smell of rotten eggs <br /> or cabbage;a musty, <br /> earthy,or moldy odor <br /> is normal) <br /> oily film Visual;inside tank None(no red,blue, <br /> gmw,L or orange <br /> sheen) <br /> Foam Visual;inside tank None <br /> pH Field 6-9 <br /> Date Date: <br /> Signature Signature <br /> Field Sampler Lab Technician <br /> To check for clarit�s service providers can carry a!ab-prrpared sample bottle or bottles with known turbiditus of l5 <br /> JTUs and 30JTUs,to compare against,or can use a portable turbidity meter.Always put effluent sample in a clear <br /> glass container or beaker to evaluate clarity Using a small removable sticker, write the date place it low on the <br /> beaker,and photograph for documentation. <br /> To check for odor,service providers can simply sniffthe eluent sample with the assistance of an olfactorysnifter <br /> device an&J r su#Ur odor measuring packet: Whenever possible, interview system users about odor occurrences and <br /> request users asshutnce in verifying or detecting odors. <br />