April 06, 2007 Lab ID : STK732332 <br /> Neil Anderson & Associates Customer : 3-9574 <br /> Quality Control - Inorganic <br /> Fat <br /> Method DatelID Type Units Conc. QC Data DQO Not300.0 03/0912007:A 00-CCB ppm ND <0.4 <br /> 00-1CV ppm 40.00 102% 90-110 <br /> 00-CCV ppm 20.00 99.8% 90-110 <br /> Nitrate + Nitrite as N 450ONO3F 04/04/2007:C 00-ICB mg/l ND <0.1 <br /> 00-CCB mg1l ND <0.1 <br /> 00-lCV mg/l 4.000 102% 90-110 <br /> 00-CCV mg/1 4.000 102% 90-110 <br /> Nitrite 300.0 03/09/2007:A215 LCS mg/L 15.00 96.4% 90-110 <br /> MS mg/L 300.0 129% 91-121 435 <br /> (CH 771279-01) MSD mg/L 300.0 121% 91-121 <br /> MSRPD mglL 6.2% s23.8 <br /> 300.0 03/09/2007:A 00-ICB ppm ND <0.3 <br /> 00-CCB ppm ND <0.3 <br /> 00-ICV ppm 30.00 101% 90-110 <br /> 00-CCV ppm 15.00 95.8% 90-110 <br /> PH 4500-H B 03/09/2007:A246 Dup units 0.0% 4.80 <br /> 4500-H B 0310912007:A 00-CCV units 8.000 100% 95-105 <br /> Solids, Total Suspended (TSS) 2540D 03/13/2007:A236 Blank mg/L ND <10 <br /> LCS mg/L 1000 42.6% 38-138 <br /> Dup mg/L 0.0% 28.7 <br /> Explanations <br /> 408 Matrix Spike(MS) or Post Digestion Spike(PDS) has no Acceptance Range (DQO) because of high analyte <br /> concentration in the sample. Data was accepted based on the LCS or CCV recovery. <br /> 435 Sample matrix may be affecting this analyte. Data was accepted based on the LCS or CCV recovery. <br /> Definitions <br /> Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> RgBlk Method Reagent Blank - Prepared to correct for any reagent contributions to sample result. <br /> LCS Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte <br /> recovery. <br /> MSlMSD Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication o <br /> how that sample matrix affects analyte recovery. <br /> Dup Duplicate Sample - A random sample with each batch is prepared and analyzed in duplicate. The relative percent <br /> difference is an indication of precision for the preparation and analysis. <br /> ICB Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> ICV Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> CCB Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> CCV Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> ND Non-detect - Result was below the DQO listed for the analyte. <br /> <1/4 High Sample Background - Spike concentration was less than one forth of the sample concentration. <br /> DQO Data Quality Objective - This is the criteria against which the quality control data is compared. <br /> STK732332: Quality Control Page 2 <br />