February 01, 2007 Lab ID : STK730134 <br /> Neil Anderson & Associates Customer : 3-9574 <br /> Quality Control - Inorganic <br /> =Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Wet Chem <br /> Nitrite 300.0 01/04/2007:13215 MS mg/L 300.0 111% 91-121 <br /> (STK730135-06) MSD mg/L 300.0 108% 91-121 <br /> MSRPD mg/L 2.8% 523.8 <br /> 300.0 01104/2007:A 00-ICB ppm ND <0.3 <br /> 00-CCB ppm ND <0.3 <br /> 00-1CV ppm 30.00 100% 90-110 <br /> 00-CCV ppm 15.00 97.5% 90-110 <br /> Nitrogen, Total Kjeldahl 351.1 0110812007:A242 Blank mg/L ND <0.5 <br /> LCS mg/L 2.000 105% 69-125 <br /> MS mg/L 2.000 79.0% 0-149 <br /> (SP 612562-01) MSD mg/L 2.000 66.6% 0-149 <br /> MSRPD mg/L 0.25 50.500 <br /> Ammonia Nitrogen 351.1 01/12/2007:A 00-ICS mg/l ND <0.2 <br /> 00-CCB mg/1 ND <0.2 <br /> 00-ICV mg/1 2.000 92.8% 90-110 <br /> 00-CCV mg/1 2.000 92.8% 90-110 <br /> pH 4500-H B 01/0312007:S346 Dup units 0.0% 0.995 <br /> 4500-H B 01103/2007:S O0-CCV units 8.000 99.2% 95-105 <br /> Solids, Total Suspended (TSS) 2540D 01/09/2007:A236 Blank mg/L ND <10 <br /> LCS mg/L 500.0 83.2% 38-138 <br /> Dup mg/L 0.50 10 <br /> Explanations <br /> 408 Matrix Spike(MS) or Post Digestion Spike(PDS) has no Acceptance Range (DQO) because of high analyte <br /> concentration in the sample. Data was accepted based on the LCS or CCV recovery. <br /> 435 Sample matrix may be affecting this analyte. Data was accepted based on the LCS or CCV recovery. <br /> Definitions <br /> Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> RgBlk Method Reagent Blank - Prepared to correct for any reagent contributions to sample result. <br /> LCS Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte <br /> recovery. <br /> MSIMSD Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication lo <br /> how that sample matrix affects analyte recovery. <br /> Dup Duplicate Sample - A random sample with each batch is prepared and analyzed in duplicate. The relative percent <br /> difference is an indication of precision for the preparation and analysis. <br /> ICB Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> ICV Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> CCB Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> CCV Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> ND Non-detect - Result was below the DQO listed for the analyte. <br /> <14 High Sample Background - Spike concentration was less than one forth of the sample concentration. <br /> DQO Data Quality Objective - This is the criteria against which the quality control data is compared. <br /> STK730134: Quality Control Page 2 <br />