My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_MONIT RPTS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
401
>
4200 – Liquid Waste Program
>
PR0526172
>
ARCHIVED REPORTS_MONIT RPTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2020 7:43:29 PM
Creation date
8/5/2020 10:00:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
MONIT RPTS
RECORD_ID
PR0526172
PE
4242
FACILITY_ID
FA0017710
FACILITY_NAME
ANKA NORTHSTAR
STREET_NUMBER
401
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
MANTECA
Zip
95336
APN
24130052
CURRENT_STATUS
01
SITE_LOCATION
401 S AIRPORT WAY
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\4200 - Liquid Waste\A\AIRPORT WAY\401\PR0526172\MONIT RPTS.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
February 01, 2007 Lab ID : STK730134 <br /> Neil Anderson & Associates Customer : 3-9574 <br /> Quality Control - Inorganic <br /> =Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Wet Chem <br /> Nitrite 300.0 01/04/2007:13215 MS mg/L 300.0 111% 91-121 <br /> (STK730135-06) MSD mg/L 300.0 108% 91-121 <br /> MSRPD mg/L 2.8% 523.8 <br /> 300.0 01104/2007:A 00-ICB ppm ND <0.3 <br /> 00-CCB ppm ND <0.3 <br /> 00-1CV ppm 30.00 100% 90-110 <br /> 00-CCV ppm 15.00 97.5% 90-110 <br /> Nitrogen, Total Kjeldahl 351.1 0110812007:A242 Blank mg/L ND <0.5 <br /> LCS mg/L 2.000 105% 69-125 <br /> MS mg/L 2.000 79.0% 0-149 <br /> (SP 612562-01) MSD mg/L 2.000 66.6% 0-149 <br /> MSRPD mg/L 0.25 50.500 <br /> Ammonia Nitrogen 351.1 01/12/2007:A 00-ICS mg/l ND <0.2 <br /> 00-CCB mg/1 ND <0.2 <br /> 00-ICV mg/1 2.000 92.8% 90-110 <br /> 00-CCV mg/1 2.000 92.8% 90-110 <br /> pH 4500-H B 01/0312007:S346 Dup units 0.0% 0.995 <br /> 4500-H B 01103/2007:S O0-CCV units 8.000 99.2% 95-105 <br /> Solids, Total Suspended (TSS) 2540D 01/09/2007:A236 Blank mg/L ND <10 <br /> LCS mg/L 500.0 83.2% 38-138 <br /> Dup mg/L 0.50 10 <br /> Explanations <br /> 408 Matrix Spike(MS) or Post Digestion Spike(PDS) has no Acceptance Range (DQO) because of high analyte <br /> concentration in the sample. Data was accepted based on the LCS or CCV recovery. <br /> 435 Sample matrix may be affecting this analyte. Data was accepted based on the LCS or CCV recovery. <br /> Definitions <br /> Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> RgBlk Method Reagent Blank - Prepared to correct for any reagent contributions to sample result. <br /> LCS Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte <br /> recovery. <br /> MSIMSD Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication lo <br /> how that sample matrix affects analyte recovery. <br /> Dup Duplicate Sample - A random sample with each batch is prepared and analyzed in duplicate. The relative percent <br /> difference is an indication of precision for the preparation and analysis. <br /> ICB Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> ICV Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> CCB Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> CCV Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> ND Non-detect - Result was below the DQO listed for the analyte. <br /> <14 High Sample Background - Spike concentration was less than one forth of the sample concentration. <br /> DQO Data Quality Objective - This is the criteria against which the quality control data is compared. <br /> STK730134: Quality Control Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.