My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_NL STDY
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PONDEROSA
>
7960
>
4200 – Liquid Waste Program
>
PR0524490
>
COMPLIANCE INFO_NL STDY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2020 5:06:05 PM
Creation date
8/5/2020 10:09:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
NL STDY
RECORD_ID
PR0524490
PE
4242
FACILITY_ID
FA0016426
FACILITY_NAME
KINGDOM HALL OF JEHOVAHS WITNESS
STREET_NUMBER
7960
STREET_NAME
PONDEROSA
STREET_TYPE
ST
City
FRENCH CAMP
Zip
95231
APN
19314008
CURRENT_STATUS
01
SITE_LOCATION
7960 PONDEROSA ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\4200 - Liquid Waste\P\PONDEROSA\7960\PR0524490\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
September 20,2001 <br /> Job Number: LGO1-098 <br /> Page I 1 <br /> An engineered septic system which performs onsite reduction of nitrates would decrease <br /> the impact to a level below the maximum contaminate level for drinking water. A buildup of <br /> nitrates above the maximum contaminate level would probably not occur if such a system could <br /> achieve an average nitrate concentration no greater than 17 mg/L-N. This type of performance is <br /> reported to be available utilizing pre-designed systems such as Orenco or MicroSeptic. <br /> VIII. CONCLUSIONS AND RECOMMENDATIONS i <br /> In conclusion, a satisfactory percolation rate xas achieved on the property. We <br /> encountered silty-sand type soils at the surface followed by fine sandy soils to a depth of <br /> exploration of 8 feet. The septic permit review has shown that conventional septic systems are <br /> used in the area. The depth to ground water at the site was found to be about 34 feet in the east <br /> well. The nitrate level measured in a functioning well located at the fire station across the street <br /> is 0.71 mg/L as nitrate N or 710 ug/L as nitrate N. The Environmental Protection Agency <br /> maximum contaminate level for drinking water for nitrate is 10 mg/L as nitrate N and 1,000 ug/L <br /> as nitrate N (or 45 mg/L as NO3). The source of the high nitrate found in the onsite well is <br /> probably nonrepresentative of the aquifer and maybe due to an unsuitable water sample <br /> collected from the idle well. <br /> The nitrate loading analysis has shown that the use of a"typical" or standard type of <br /> septic system could potentially cause a build up of nitrogen in the shallow aquifer above the <br /> maximum contaminate level of 10 mg/L-N. Utilizing an engineered septic system, designed to <br /> reduce nitrates in effluent, will not cause a build up of nitrates above the maximum contaminate <br /> level of 10 mg/L-N. <br /> Based on the results of this study, the proposed project is suitable for use with an <br /> engineered s�ti�stem specially designed to reduce nitrates. If this system is utilized, we do <br /> not believe it will cause a build-up of nitrates above the maximum contaminant level of 10 mg/L- <br /> N. The recommendations for the project are as follows: <br /> 1) An engineered septic system, designed to reduce nitrate levels below 17 mg/L-N <br /> prior to leachfield disposal, is required to prevent a build up of nitrates above <br /> maximum contaminant level for drinking water of 10 mg/L-N. Some leach field <br /> improvements will be needed to reduce percolation and obtain a denitrification <br /> factor of 35 percent. <br /> 2) A qualified civil engineer or professional should be consulted regarding the <br /> design and performance of the engineered septic system.As part of a sepai-ate <br /> scope of work, we would be pleased to provide these services. <br /> r cc+�so4 <br /> = ti <br /> 0 <br /> r <br /> �Isoc. <br />