My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2012 1ST QUARTER MONITORING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VIA NICOLO
>
17950
>
4200 – Liquid Waste Program
>
PR0521836
>
ARCHIVED REPORTS_2012 1ST QUARTER MONITORING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2020 9:15:17 AM
Creation date
8/5/2020 10:12:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2012 1ST QUARTER MONITORING
RECORD_ID
PR0521836
PE
4232
FACILITY_ID
FA0002971
FACILITY_NAME
MUSCO FAMILY OLIVE CO
STREET_NUMBER
17950
Direction
W
STREET_NAME
VIA NICOLO
City
TRACY
Zip
95377
APN
20911032
CURRENT_STATUS
01
SITE_LOCATION
17950 W VIA NICOLO
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\4200 - Liquid Waste\V\VIA NICOLO\17950\PR0521836\ARCHIVED REPORTS\2012 1ST QUARTER MONITORING.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENVIRONMENTAL _- <br /> AGRICULTURAL <br /> Analytical Chemists <br /> April 2, 2012 Lab ID : STK1232452 <br /> Musco Family Olive Environmental Customer : 3-11544 <br /> Quality Control-Inorganic <br /> Constituent Method Date/ID Type Units Cone. QC Data DQO Note <br /> Metals <br /> Sodium 200.7 MS mg/L 12.00 90.8% 75-125 <br /> (CC 1280684-001) MSD mg/L 12.00 91.3% 75-125 <br /> MSRPD m 3996 0.6% <20.0 <br /> 200.7 03/26/12:204403rs CCV ppm 25.00 94.3% 90-110 <br /> CCB ppm -0.05 1.0 <br /> CCV ppm 25.00 92.5% 90-110 <br /> CCB ppm 0.01 1.0 <br /> Wet Chem <br /> Solids,Total Dissolved 2540 C 03/23/12:203203CHL Blank mg/L ND <20 <br /> LCS mg/L 995.0 98.1 % 90-110 <br /> SP 1202914-001 Du m 0.5% 10.0 <br /> Solids,Suspended 2540G 03/22/12:310413CTH Blank mg/kg ND <1 <br /> LCS mg/kg 500.0 96.5% 38-138 <br /> LCS mg/kg 500.0 98.5% 38-138 <br /> STK 1232419-001 LuL m 2.2% 28.7 <br /> Nitrate 300.0 03/22/12:203181CHL LCS mg/L. 20.00 99.5% 90-110 <br /> MS mg/L 400.0 105% 88-124 <br /> (SP 1202773-008) MSD mg/L 400.0 105% 88-124 <br /> MSRPD mg/L 100.0 0.09% 529.1 <br /> 300.0 03/22/12:204225CHL CCB ppm 0.093 0.4 <br /> CCV ppm 20.00 103% 90-110 <br /> CCB ppm 0.092 0.4 <br /> CCV ppm 20.00 104% 90-110 <br /> CCB ppm 0.092 0.4 <br /> CCV ppm 20.00 103% 90-110 <br /> Nitrogen,Total Kjeldahl 351.2 03/23/12:203184CJJ Blank mg/L, ND <I <br /> LCS mg/L 12.00 92.8% 41-148 <br /> MS mg/L 12.00 82.6% 25-149 <br /> (CH 1271472-001) MSD mg/L 12.00 88.5% 25-149 <br /> MSRPD mg/L 12.00 6.7% 525.7 <br /> OD 5210B 03/21112:300174CTH RgBlk mg/L 0.46 2 b <br /> RgBlk mg/L 0.39 2 b <br /> LCS mg/L 198.0 88.1% 84.6-115 <br /> LCS mg/L 198.0 89.5% 84.6-115 <br /> (STK1232475-002) Dup mg/L 7.1% 15.9 <br /> (STK1232475-002) Dup mg/L 1.2% 15.9 <br /> STK1232475-002 Dup mg/L 20.6% 15.9 440 <br /> 5210B 03/26/12:300174CTH CCV m L 1.000 99.0% 80-120 <br /> Nitrogen,Total Kjeldahl EPA351.2 03/26/12:204287AMB CCB mg/L 0.367 0.5 <br /> CCV mg/L 1.000 105% 90-110 <br /> CCB mg/L 0.294 0.5 <br /> CCV mi/L- 1.000 96.4% 90-110 <br /> Definition <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> RgBlk :Method Reagent Blank-Prepared to correct for any reagent contributions to sample result. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyted.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> Dup :Duplicate Sample-A random sample with each batch is prepared and analyzed in duplicate.The relative percent difference is an <br /> indication of precision for the preparation and analysis. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> nebrte.c, and analysis. <br /> Page 9 of I 1 <br /> Corporate Offices&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory Field Office <br /> 853 Corporation Street 2500 Stagecoach Road 563 E.Lindo Avenue 3442 Empresa Drive,Suite D Visalia,California <br /> Santa Paula,CA 93060 Stockton,CA 95215 Chico,CA 95926 San Luis Obispo,CA 93401 TEL:(559)734-9473 <br /> TEL:(805)392-2000 TEL:(209)942-0182 TEL:(530)343-5818 TEL:(805)783-2940 Mobile:(559)737-2399 <br /> Env FAX:(805)525-4172/Ag FAX:(805)392-2063 FAX:(209)942-0423 FAX:(530)343-3807 FAX:(805)525-4172 FAX:(559)734-8435 <br /> CA NELAP Certification No.01110CA CA ELAP Certification No.1563 CA ELAP Certification No.2670 CA ELAP Certification No.2775 <br />
The URL can be used to link to this page
Your browser does not support the video tag.