Laserfiche WebLink
22222� <br /> Frnow <br /> NCLUSIONS AND RECOMMENDATIONS <br /> test results for this sampling event indicate reductions on all constituents tested between the <br /> ond compartment of the septic tank and all three ES. The nitrate-nitrogen concentration is <br /> at ND levels primarily due to the installation of timers to cause cycling aeration for one hour <br /> and one hour on. <br /> There was a decrease in the Average Daily Flow(ADF)measured in gallons per day (gpd) of 72 <br /> gpd from the last sampling event. <br /> As noted in Table 2, effluent flows are not undergoing equal distribution between the three ES. <br /> The Automatic Distributing Valve has been cleaned and serviced. The valve may be replaced if <br /> the next readings are not relatively equal among the three ES. <br /> If there should be any questions regarding the information contained within this Report, please <br /> contact the undersigned. <br /> Respectfully submitted, QRGFESS/p <br /> CHESNEY ENGINEERING, INC. o� CHF y�<<y� <br /> r C 75479 M <br /> CIVIL <br /> Don Chesney, PE OF CAL <br /> Registered Civil Engineer C75479 <br /> Page -3- <br /> Chesney Engineering, Inc. <br />