COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2300 - Underground Storage Tank Program
>
PR0231761
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 10:43:30 AM
Creation date
8/6/2020 1:33:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231761
PE
2361
FACILITY_ID
FA0002347
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax; (209) 468-3433 Web: www.sjaov.orct/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />ERNIES GENERAL STORE <br />Facility Address: <br />4407 E WATERLOO RD, STOCKTON <br />Date: <br />January 15, 2019 <br />UST System Observations <br />316 <br />HSC 25290.1(c3), <br />25290.2(c3) <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />❑ V ❑ R ❑ COS <br />317 <br />CCR 2636, 2643(c)(1), <br />2666(f) <br />Line leak detector (LLD) not installed <br />❑ V ❑ R ❑ COS <br />318 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch <br />❑ V ❑ R ❑ COS <br />319 <br />CCR 2635, 2637. 1, <br />2665, 2712 <br />No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested <br />❑ V ❑ R ❑ COS <br />320 <br />CCR 2635, 2637.2, <br />2665, 2712 <br />Failure to comply with the installation, inspection, or record keeping of the overfill prevention <br />❑ V ❑ R ❑ COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V ❑ R ❑ COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />❑ V ❑ R ❑ COS <br />330 <br />CCR 2636(f), 2666(c), <br />2666(f) <br />No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm <br />❑ V ❑ R ❑ COS <br />331 <br />CCR 2630(d), 2641(a) <br />Liquid does not flow into the sump in the event of a leak (i.e., failure to remove test boot). <br />❑ V ❑ R ❑ COS <br />332 <br />CCR 2631(b&d), <br />2666(b&e) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />❑ V ❑ R ❑ COS <br />333 <br />CCR 2635, 2636(b), <br />2662, 2712 <br />Failure to comply with the cathodic protection system requirements <br />❑ V ❑ R ❑ COS <br />334 <br />CCR 2666(b)(2) <br />Single -walled pipe not upgraded to double -walled interstitially monitored pipe during repair <br />❑ V ❑ R ❑ COS <br />335 <br />CCR 2630, 2632, 2643, <br />2644.1 <br />Equipment or methods used to monitor the UST system are not certified by an independent third -party <br />❑ V ❑ R ❑ COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3), <br />2641(b) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />No monitoring or record maintenance for single -walled conventional suction systems (pre -Jan 1984). <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d), 2661(f) <br />Failure to conduct 0.1 gph test for single -walled conventional suction systems (pre -Jan 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e), 2661(f) <br />Biennial 0.1 gph line integrity test for single -walled gravity piping not performed (pre -Jan 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # Remarks <br />Overall Inspection Comments: <br />FA0002347 PR0231761 SCO01 01/15/2019 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.