My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0081813
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
13550
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0081813
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:48:04 PM
Creation date
8/11/2020 2:27:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0081813
PE
4201
FACILITY_NAME
JOE GRINDSTONE ASSOCIATION
STREET_NUMBER
13550
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05502002
ENTERED_DATE
2/26/2020 12:00:00 AM
SITE_LOCATION
13550 HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
166
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.3.7.4.3. We recommend that you use one of our strap systems with <br />our factory -supplied deadmen. <br />1.3.7.4.4. When installing any size tank, and when using our D-ring/D- <br />ring anchor straps and prefabricated deadmen, the deadmen are to be <br />placed so that their tops are even with the bottom of the tank. See Figure <br />1-6 and Table 1-4 for anchor -point dimensions when using our deadmen <br />• For 8 -foot -,10 -foot- and 12 -foot -diameter tanks, an option when using <br />D-ring/D-ring straps is to place the deadmen on the bedding so the <br />bottoms of the deadmen are even with the bottom of the tank. <br />• This is not recommended for 4 -foot- and 6 -foot -diameter tanks. <br />1.3.7.4.5. The width and thickness of a deadman depends <br />on the following: <br />• tank diameter <br />• water -table elevation <br />• number of containment sumps <br />• burial depth <br />1.3.7.4.6. The total length of a deadman (on each side of the tank) <br />is typically equal to the length of the tank. <br />• Our prefabricated deadmen come in various lengths. <br />• Dead men are to be butted together end to end on each side of the <br />tank when multiple sections are used. <br />• Depending on the installation, multiple deadmen may be required <br />and are to adhere to the following: <br />The total length of the assembled deadmen must be appropriate <br />for the installed tank. <br />Each section of assembled deadmen must contain at least two <br />balanced anchor points. <br />An equal number of deadmen is required on both sides <br />of the tank. <br />• Our prefabricated deadmen are supplied with 3/4 -inch -diameter <br />galvanized adjustable anchor points (subsequently referred <br />to as anchor points). See Figure 1-10. <br />These anchor points protrude up through the slots in the deadmen <br />and are temporarily supported with cotter pins. <br />A WARNING <br />Only use the anchor points when lifting and positioning the <br />deadmen. A spreader bar may be required to lift longer sections <br />of deadmen. Use guide ropes to guide the deadmen when lifting. <br />Failure to do so could result in death or serious injury. <br />Chain or Sling <br />60° to 90° <br />Anchor Point \ / \ I Anchor Point <br />Alignment Slot / Alignment Slot <br />12 <br />1.3.7.4.7. See Table 1-5 for typical deadmen dimensions fortanks <br />(other than 10 -foot -diameter tanks with a capacity greaterthan 25,000 <br />gallons [95,000 liters], given the following scenario: <br />• an empty tank <br />• a 3 -foot [91 -cm] burial depth <br />• groundwater to grade <br />• 1 containmentsump <br />Tank Diameter Typical Deadmen Dimensions (Width x Depth) <br />6 -foot 12" [30 cm] x 12" [30 cm] <br />8 -foot 12" [30 cm] x 12" [30 cm] <br />10 -foot 18" [46 cm] x 9" [23 cm] <br />12 -foot 36" [91 cm] x 8" [20 cm] <br />1.3.7.4.8.Tankswith more than 1 containment sump and 10 -foot -di- <br />ameter tanks with a capacity greater than 25,000 gallons [95,000 liters] <br />may require either a deeper burial or deadmen <br />larger than those shown in Table 1-5. Contact technical support <br />(ena.support@zcl.com) for further information. <br />1.3.7.4.9. The minimum spacing between tanks must be increased <br />to accommodate deadmen. <br />1.3.7.4.10. Always provide sufficient clearance to allow the <br />deadmen to be set outside the tank "shadow" See section 1.3.5 <br />for tank spacing information. <br />1.3.7.4.11. For placement of prefabricated deadmen, <br />see Figure 1-2. <br />1.3.7.4.12. Some contractors use the deadmen as a construction <br />guide for proper depth of bedding. <br />1.3.7.4.13. If our prefabricated 18 -inch- [45 cm] wide low -profile <br />deadmen are used as a construction guide, they may need to be <br />elevated. This can be accomplished by putting 3'/2 inches [9 cm] of <br />backfill or a 4 x 4 piece of wood (or equivalent) underneath so that <br />the top of the deadmen is 12 inches [30 cm] off of the bottom of the <br />excavation. See Figure 1-11. <br />Backfill 18" Wide Low Profile Deadmen <br />I, I, 4x, <br />::WWBWW8111111 IIIIIIBWWBWW <br />NOTE: Low -profile deadmen are not 12 inches [30 cm] high. <br />1.3.7.5. TURNBUCKLES <br />1.3.7.5.1. We also offer a turnbuckle that will connect the <br />deadman anchor point to the FRP anchor strap. See Figure 1-8. <br />When the deadman is properly positioned, this will eliminate <br />the use of wire rope. See section 1.3.7.2 for more detail <br />on anchor straps. <br />
The URL can be used to link to this page
Your browser does not support the video tag.