Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CRESTWOOD
>
2056
>
1600 - Food Program
>
PR0546092
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2020 5:01:47 PM
Creation date
8/11/2020 2:58:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546092
PE
1617
FACILITY_ID
FA0024277
FACILITY_NAME
ARCO AM/PM-ASP PETROLEUM
STREET_NUMBER
2056
STREET_NAME
CRESTWOOD
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2056 CRESTWOOD AVE
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLUE CAP <br /> CONICAL ROOF CAP WITH <br /> CAULKED JOINTS. DIM. SHALL SEAL WITH HIGH <br /> CONCENTRIC FLUE TEMPERATURE SILICONE <br /> MATCH DUCT SIZE SHOWN � RUBBER SEALANT ROBISON <br /> SECURE TO ON PLANS <br /> FLEXIBLE STRUCTURE 26 GA. G.I. FLASHING OVER 4" <br /> ENGINEERING, INC <br /> CONNECTION \ ,45 CONT. CANT STRIP BY ROOFING VENTED CURB 1940140TH AVE W.,SUITE 302 <br /> 1 1/2"X1 1/2"X16 CONTRACTOR. LYNNW364- WA98036 <br /> EXHAUST � .�.�.�.�- GAGE FLASHING 206-364.3343 TEL <br /> DUCT DIAGONAL BRACE <br /> 16 GA. CHANNEL 12" HIGH ROOFING CONTACT:MARK MANGLICMOT <br /> X 2" DEEP PLUS WOOD <br /> 12 ' < CURB. <br /> pFESS/pN <br /> .: . . ROOF DECK R0�9��` <br /> . . . ..... <br /> PROVIDE /)DIRECT FLUE 3" MIN Cz <br /> NEOPRENE o. M-28712 <br /> VENT CHASEISOLA <br /> w m <br /> PADS TOR ROOFING CONCENTRIC ADAPTER - 0_19 <br /> y COMBUSTION AIRCHAtA <br /> ANGLE ROOF DECK TO WATER HEATER T9TFFOF CALF <br /> GRILLE MOUNTING STRUCTURAL SUPPORTS. Seal 03-22-18 <br /> FURNISHED WITH BRACKET FURNISHED REFERENCE STRUCTURAL <br /> FANWITH FAN DRAWINGS. m e <br /> DUCT DOWN TO FLUE DUCT FROM ® ®— <br /> CEILING EXHAUST FAN WATER HEATER 4_ <br /> s <br /> �s s� <br /> NOT USED N.T.S. 4 CEILING EXHAUST FAN DETAIL N.T.S. 3 ROOF JACK DETAIL N.T.S. 2 DIRECT FLUE VENT ON ROOF N.T.S. 1 <br /> ® . ® — <br /> THESE TWO HANGERS ARE FOR DUCTS 25" & THIS HANGER IS FOR DUCTS <br /> LARGER (MAY BE USED ON SMALLER DUCTS) 24" DIA. & SMALLER <br /> ROOF MOUNTED EXHAUST FAN <br /> 1/4" BOLT, NUT & FURNISHED W/ ROOF CURB, ACOUSTICAL <br /> " " STAR WASHER (TYP.) 3 8" BOLT, NUT & NOTE: ALL JOINTS IN DUCTWORK TO BACKDRAFT DAMPER, FAN SPEED 2" WIDE METAL FLEXIBLE DUCT MAX. <br /> 3/8 DIA. ROD OR 1X16 / <br /> GA. HANGER STRAP (TYP.) STAR WASHER BE SOLDERED WATERTIGHT. VERIFY CONTROLLER, FACTORY MOUNTED STRAPS 4'-0" LONG <br /> CURB DIMENSIONS WITH MECHANICAL DISCONNECT SWITCH, <br /> DRAWINGS. & WIRE MESH SCREEN <br /> 11"X16 GA. HANGER 1"X16 GA. <br /> 2 <br /> NUT & LOCKNUT <br /> STRAP » J <br /> MAX. CONTINUOUS COLLAR <br /> DRAWN TIGHT QSUPPLY AIR DUCT <br /> AROUND DUCT SECURE FAN TO CURB W/SHT. METAL <br /> FASTENERS @ 12" O.C. (MIN. 2 PER SECURE TO 45° m <br /> MOTOR AND SIDE) BY G.C. STRUCTURE 7D <br /> CO <br /> DRIVE ABOVE 1 D <br /> 1"X16 GA. CONTINUOUS HANGER STRAP + Z ~ <br /> 1-1 8"X12 GA. SPLIT RING (TYP.). EACH STRAP ADJACENT TO ONE 4 CANT FACTORY CURB SUPPLIED W/ FAN. 715 O � <br /> / INSTALLED BY G.C. > <br /> COLLAR AROUND DUCT ANOTHER AT HANGER LOCATION (TYP.) ROOF ATTACH CEILING WIRES AT L CD <br /> ROOF UP OVER FACTORY CURBDIFFUSERS TWO OPPOSING Z <br /> ROUND DUCT HANGER 8"MIN. R CORNERS o <br /> 2"X2"X1/8" ANGLE 8" MIN D <br /> 1"X16" GA. HANGER 3/8" DIA. ROD OR TOP & BOTTOM OPPOSED BLADE DAMPER M <br /> STRAP (TYP.) 1"X16 GA. HANGER Q <br /> STRAP ROOF STRUCTURE 6 TURNS z <br /> — MAX. -I AT 1-1/2" 00 <br /> WOOD NAILERS ALL WOOD IS OPERATOR Q N <br /> TRIM ©45° PRESSURE TREATED. SLOT o <br /> #— 61" & —k ANGLE (TYP.) BACKDRAFT DAMPER SUPPLIED W/I . 4\ CEILING o <br /> L30"MAX. SHEET METAL 1"X18 GA. STRAP OVER EXHAUST DUCT. SEE FLOOR FAN. INSTALLED BY G.C. a a a a a a a a <br /> SCREWS (TYP.) PLAN FOR ROUTING <br /> OVER DUCT (TYP.) CEILING <br /> OVAL/RECTANGULAR DUCT HANGER DIFFUSER <br /> NOTES: <br /> 1. REFER TO SPECIFICATIONS FOR HANGER SPACINGS. NOTE: <br /> 2. ATTACHMENTS TO OVERHEAD STRUCTURE SHALL BE MADE IN ACCORDANCE WITH STRUCTURAL 1) IN LIEU OF ABOVE DETAIL METAL PLENUM MAY BE USED TO <br /> ENGINEER'S REQUIREMENTS AND WEIGHT LIMITATIONS. ALL ATTACHMENT METHODS TO STRUCTURE SHALL CONNECT THE BRANCH DUCT TO THE DIFFUSERS. ELBOW R/D=1 .5 <br /> BE SUBMITTED TO STRUCTURAL ENGINEER FOR REVIEW. 0 <br /> DUCT SUPPORT DETAIL N.T.S. 7 MUSHROOM TYPE EXHAUST FAN N.T.S. 6 CEILING DIFFUSER DETAIL N.T.S. 50 W <br /> Q 0CZ (0 <br /> W o > c` ) <br /> 0Lo <br /> /TURNING <br /> SLOPE NOT TO EXCEED 1 SLOPE NOT TO z <br /> VANES RECTANGULAR DUCT W = <br /> IN 4 EXCEED 1" IN 4" Q C O Q <br /> ROUND DUCT J O U <br /> DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES -1/2WJ - <br /> TYPICAL RECTANGULAR TO ROUND TRANSITION MM <br /> ,,� TYPICAL RECTANGULAR TRANSITION <br /> ROOFTOP EQUIP - NEOPRENE RUBBER GASKET `L W Cn U <br /> SEE SPECS RECTANGULAR DUCTS _ USE THIS DESIGNO W W <br /> SE THIS DESIGN � <br /> FILL CAVITY WITH RTV ELS ARE SHOWN ON WHERE SQUARE 90° INSTALLATION NOTES <br /> MAXIMUM SIZE STEEL ALUMINUM ELBOWS ARE SHOWN rr^^ fr <br /> SEISMIC RESTRAINT BRACKET SILICONE PLANS( WHERE INCHES) (MINIMUM THICKNESS, NOMINAL) (MINIMUM THICKNESS, NOMINAL) R UND 90° 2' ON PLANS OR IF 1 1 1. ALL DUCTS SHALL BE CONSTRUCTED AND ERECTED IN A NEAT AND WORKMANLIKE MANNER. VJ U z <br /> TYP. FOUR (4) PER UNIT \ SPACE CONDITIONS DO L Q <br /> NOT PERMIT 2. DUCT SHALL BE CONSTRUCTED OF THE WEIGHTS, GAGES AND MATERIAL SHOWN IN THE Q O Q <br /> 2X4 WOOD NAILER STRIP. THROUGH 12 0.022 INCH (26 GAGE, GALV.) 0.020 INCH (NO. 24 B&S GAGE) INSTALLATION DETAIL OF TURNING VANES SCHEDULE ON THESE DRAWINGS. U z <br /> FACTORY PROVIDED 13 THROUGH 30 0.028 INCH (24 GAGE, GALV.) 0.025 INCH (NO. 22 B&S GAGE) ROUND 90° ELBOWS SQUARE 90° ELBOWS Q <br /> Z Q �w D COUNTER FLASHING NAIL i I w <br /> � � 14 GAUGE OR HEAVIER 31 THROUGH 54 0.034 INCH (22 GAGE, GALV.) 0.032 INCH (NO. 20 B&S GAGE) 3. THE DIMENSIONS SHOWN FOR ALL DUCTS SHOWN IN PLAN GIVE THE WIDTH FIRST AND THEN <br /> & CANT STRIP BY I 1 <br /> =) CD w z ROOFING CONTR. i I GALVANIZED STEEL CURB TO 55 THROUGH 84 0.040 INCH (20 GAGE, GALV.) 0.040 INCH (NO. 18 B&S GAGE) CONSTRUCTION OF 90° ELBOWS THE HEIGHT. <br /> o - 0- .� � I MATCH ROOF SLOPE MAIN <br /> =U) ROOFING i OVER 84 0.052 INCH (18 GAGE, GALV.) 0.051 INCH (NO. 16 B&S GAGE) 4. DUCT RISERS SHOULD BE SUPPORTED BY ANGLES AT EVERY FLOOR. <br /> SAD OR RAD AIR <br /> RIGID INSULATION BY ROUND DUCTS JFL=0V�' 5. AIR TURN SHALL BE INSTALLED IN ALL ABRUBT ELBOWS TO PREVENT TURBULENCE. <br /> ROOFING CONTRACTOR TURNING BRANCH <br /> SPIRAL SEAM DUCT LONGITUDINAL SEAM DUCT FITTINGS1 VANES 6. DUCTS SHALL BE SECURELY ATTACHED TO THE BUILDING CONSTRUCTION IN AN APPROVED <br /> CURB FRAMING MANNER. <br /> 5/8"0 <br /> F''' <br /> MAXIMUM SIZE STEEL STEEL STEEL W »W» <br /> 5/8"0 LAG BOLT (HIGH —USE THIS DESIGNW SE THIS DESIGN 7. DIVERGING TRANSITION PIECES SHALL BE MADE AS GRADUAL AS POSSIBLE. Project Number <br /> TENSION "HILTI BOLTS) ® (INCHES) (MINIMUM THICKNESS, NOMINAL) (MINIMUM THICKNESS, NOMINAL) (MINIMUM THICKNESS, NOMINAL) WHERE ROUND 45° WHERE SQUARE 45' ROUND BRANCH TAKE OFF <br /> 24" O.C. (TYP.) ELBOWS ARE SHOWN ELBOWS ARE SHOWN MAIN 8. INSTALL FIRE DAMPERS IN ACCORDANCE WITH UL 555. SPA16002.0 <br /> TYPICAL INSTALLATION THROUGH 12 0.019 INCH (26 GAGE, GALV.) 0.022 INCH (26 GAGE, GALV.) 0.022 INCH (26 GAGE, GALV.) ON PLANS ON PLANS AIR <br /> ROOF FRAMING 13 THROUGH 18 0.022 INCH (26 GAGE, GALV.) 0.028 INCH (24 GAGE, GALV.) 0.028 INCH (24 GAGE, GALV.) ROUND 45° ELBOWS SQUARE 45° ELBOWS9. ACCESS PANELS SHOULD BE PLACED BEFORE AND/OR AFTER EQUIPMENT INSTALLED IN THE <br /> Sheet Name <br /> 19 THROUGH 28 0.028 INCH (24 GAGE, GALV.) 0.034 INCH (22 GAGE, GALV.) 0.034 INCH (22 GAGE, GALV.) IF, O 1/,--BRANCH DUCT. <br /> 29 THROUGH 36 0.034 INCH (22 GAGE, GALV.) 0.040 INCH (20 GAGE, GALV.) 0.040 INCH (20 GAGE, GALV.) TURNING VANES, 10. DUCT AREA SHOULD NOT BE DECREASED MORE THAN 10% WHEN OBSTRUCTIONS CANNOT BE MECHANCIAL <br /> 37 THROUGH 52 0.040 INCH (20 GAGE, GALV.) 0.052 INCH (18 GAGE, GALV.) 0.052 INCH (18 GAGE, GALV.) CONSTRUCTION OF 45° ELBOWS SEEDETAIL <br /> SIH ET AVOIDED, AND THEN A STREAMLINED FITTING SHOULD BE USED. <br /> DETAILS <br /> CONSTRUCTION OF BRANCH TAKE OFF FROM MAIN SQUARE BRANCH TAKE OFF 11. FLEXIBLE FABRIC CONNECTIONS (OR EQUAL) SHOULD BE USED ON BOTH INLETS AND OUTLETS <br /> OF ALL FANS AND AIR HANDLING UNITS. <br /> 12. JOINTS AND SEAMS OF SUPPLY DUCTS SHALL BE FASTENED SECURELY AND MADE AIR TIGHT. <br /> Sh N M601 <br /> CURB ATTACHMENT N.T.S. 1 O <br /> TO ROOF SHEET METAL GAGES N.T.S. 9 DUCT CONSTRUCTION DETAILS N.T.S. 8 <br />