Laserfiche WebLink
13 JAW UTILITY <br /> COMPANY APPROVED <br /> MS13-1 CT POWER METER <br /> ------------- <br /> QSR B-20,22 TG7A TG6 TG5A SHEET NOTES <br /> 3/4"C,2#6,#10G TG7(2) IV,' <br /> R F1�2T <br /> I E23 — TO COORDINATE ALL STUB-UP LOCATIONS WITH REFRIGERATION CONTRACTOR ROBISON <br /> GTB-23 <br /> r a° o OFFICE 1 AND REFRIGERATION EQUIPMENT INSTALLATION DRAWINGS. ENGINEERING, INC <br /> 6: 18 a a I O STUB UP CONDUITS UNDER THE CHECK STAND AND TERMINATE IN 1940140TH AVE W.,SUITE 302 <br /> � � I � n " " LYNNWOOD.WA98036 <br /> D ° _ - Ta <br /> -6 o B-35 �/V� 1 4 14 SEPARATE 8x8 x6 BOXES FOR POWER AND LOW VOLTAGE SYSTEMS, 2os-OOD. A98 <br /> In 3 TEL <br /> G-20 L 13/4"C, #6,#1Q0G B-27 B-16 - B-14 C-30 MOUNTED 4" ABOVE FINISHED FLOOR COIL 10' OF ALL POWER WIRING. <br /> PREPB-21 CONTACT:TYLER BEAM <br /> Ir I. �B�2� C-18 D10 D10 O O3 INSTALL (2) 1 1/2"C UNDER FLOOR CONDUITS FOR LOW VOLTAGE - ONE TO <br /> m UTILITY <br /> 'T7 �/ B-26 COOLER DOOR LIGHTS THE TELEPHONE BOARD AND ONE TO THE SECURITY PANEL INSIDE STORAGE <br /> A V 1 ILI 1 1 oma G2 G22 g_18 J D2D WALK-IN AREA. QROFESS/pN� <br /> MSB-2 UNITIZED B � O � L-24 COOLER O4 PROVIDE J-BOX FOR CONNECTION OF DOOR SHUTTERS. INSTALL " �`�� ���ER eFq F� <br /> PANEL SYSTEM CO2 SENSOR RECEPTACLE — — WEATHERPROOF OUTLET BOX NEAR WINDOW SECTIONS AS SHOWN, 1/2- <br /> L <br /> /2 <br /> C A-11,13 17 DOOR CONDUIT WITH PULL CORD AND EXTENSION TO PANEL VIA INDOOR J-BOX . 0 No. E-21545 m <br /> ABO A_6 _ PROVIDE ALL NECESSARY ACCESSORY AND CONNECTION FOR COMPLETE AND w m <br /> L ABOVE <br /> GFCI 19 CASHIER OPERABLE SYSTEM. COORDINATE WITH SHUTTER VENDOR AND OWNER. ROUTE <br /> POWER FROM SHUTTERS TO SWITCH AT MANAGER' DESK TO OPERATE ALL <br /> B-39,41 1 B-12 SHUTTERS. T F�£CTR 'VJl . 111I <br /> 1"C,2#2,#8G A-$ GF TG4 TG1 B-1 g-24 y I BELOW �I 14 n F pF CAX <br /> C-26 16 13 A-39,41 I A-15 C2 C3 C2 cs O5 CARLTON FLOOR PVC FLOOR BOX OR STEEL FLOOR BOX, 4 DIAMETER WITH Seal <br /> BRONZE ADJ. RING AND CONDUIT STEEL CITY" CAT#88DA COVER 3P90 <br /> -1 A 7 F C6A \ IG IG r D10 (TYP.). LOCATE 1'-0" IN FRONT OF GONDOLAS, TYP. <br /> 12KVA,208V2P2W GFCI ° B76 ABOVE B-7 B-9/ I 0 <br /> /j TG8 o g FOR SECURITY SYSTEM INSTALL CONDUIT WITH PULL BOX AS SHOWN. b <br /> A-40 FC ■ J A-22 O STANDARD OUTLET BOXES AND PULLBOX WIRING BY OTHER COORDINATE <br /> B2A ABOVE p <br /> 1/2"C,1#8,#8N, 1 A_9 / LOCATION WITH MECHANICAL CONTRACTOR. <br /> B12 _ � B-13 B-11 I <br /> A-2,4 B2B ABOVE I 3 / / 7 SECURITY ALARM EQUIPMENT. COORDINATE FINAL LOCATION WITH SECURITY <br /> 1/2"C,2#8,#10G *91 % — / / CONTRACTOR. <br /> � �I O O I C 1 I I 2 I I <br /> 4KVA,208/120V2P3W I II _ I I <br /> A-19,21 O8 TELEPHONE BACKBOARD. INSTALL 2" CONDUIT BETWEEN TELEPHONE BOARD <br /> $ _ �� <br /> GFCI /2"C,2#10,#10N,#10G __ ' � AND SECURITY PANEL. <br /> A PEESALES AREA B-42 g COORDINATE THE SCOPE OF WORK, EQUIPMENT RATING, WIRING REQUIREMENT <br /> I B 4E A-23 O AND CONTROLS WITH REFRIGERATION EQUIPMENT CONTRACTOR./ VENDOR <br /> CK) B1 2 B-40 COOLER DOORI HTS PRIOR PROCEEDING ANY WORK. REFER TO KITCHEN/REFRIGERATION <br /> I C ALARM 1 A J D2D EQUIPMENT FOR ADDITIONAL INFORMATION , NOTIFY GENERAL CONTRACTOR IF <br /> ?63.24KVA,2O8/12OV2P3W A-20 L-25 ANY DISCREPANCY EXISTS BETWEEN EQUIPMENT RATING, WIRING <br /> I A-25,27TG4B 5 B-36 / REQUIREMENT ETC. AND THE CURRENT DESIGN.. <br /> 1/2"C,2#10,#10N,#1 OG 1 GFCI \ <br /> I � 14 <90 <br /> SHOW WINDOW RECEPTACLE TO BE LOCATED WITHIN 18" ABOVE STORE <br /> HALLWAYA-29 L g-38 //> C-32 J WINDOW. FACE PLATES TO BE PAINTED TO MATCH ADJACENT WALLS. <br /> I <br /> D10 11 CONNECT TO RESTROOM SWITCHED LIGHTING CIRCUIT, SEE E1.0 1/2"C,1#10,#1ON,#12G O & E5.0. <br /> A-12 A-14,16 12 PROVIDE J-BOX & ONE 4 PAIR CAT 5/6 TEL. FOR CONNECTION OF ATM <br /> A14 1/2»C,2#8,#10G <br /> MACHINE. COORDINATE EXACT LOCATION AND OTHER REQUIREMENTS WITHC. J <br /> �'� � � 5 <br /> F A-32 — OWNER. <br /> 1 21 HARD WIRED LAVATORY UCET A18 — T 5 m <br /> A-1 I I 13 IF ELECTRICALLY OPERATED, PROVIDE 3P 50A DISCONNECT SWITCH FOR <br /> I HARD WIRED LAV 4 ORY FAUCET C-16 " A-31# _ ELECTRIC WATER HEATER. COORDINATE EXACT LOCATION AND REQUIREMENTS cn <br /> C,2#8,#8N,#10 m , <br /> FAID DRYER C WITH PLUMBING CONTRACTOR. <br /> I <br /> ° ND DRYER A-35 o a- <br /> 1 KVA,12OV1P2W AI.KVA,120V1P2W A10 _ _ L_J 14 J-BOX FOR EVAPORATOR COILS ( PRE-FAB COOLER MANUFACTURER TO � w <br /> C 1 I A5t / _I DOOR LIGH DETERMINE EXACT LOCATION.) L <br /> I <br /> 1/2"C,1#10, ON,#12G C-14 G 1 _ 4 -8 4 6 4 z <br /> CD <br /> 1/20p 10,#10N,#12G Al2 (2) A-1 g_31 - A-5,v* _ 15 ELECTRICAL PROVISION FOR AIR CURTAIN CONNECTION (EXACT LOCATION AND <br /> I EF-1 EF-1 A_26 T �I T E2 L-23 HEIGHT TO BE DETERMINED AT SITE). m <br /> 0.048KVA,12 V 2W 0.048KVA,12 2W A10 J J � _ 14 <br /> I C16> HOT WATER CIRCULATION PUMP 120V 0.8A. FIELD COORDINATE EXACT <br /> ❑ C-3 LOCATION. <br /> I <br /> v v v _ -3 10 10 10 ATM D10 17 " z <br /> WOMEN 1 MEN O PROVIDE (2) 2 CONDUIT FOR FUTURE SOLAR PANELS. ROUTE CONDUITS TO <br /> A-37 / 1/2"C,1# ,#10N,# G D COOLER DOOR H MAIN DISTRIBUTION SERVICE MSB. w <br /> EFT - i�_k <br /> 3 1/2"C,1#10,#10N,#12G _ ACN-1 J 12 ❑ °� °� 18 BREAKER PANEL G IS PROVIDED NTH CPI (CAROLINA PRODUCTS, INC.) Q N <br /> I A-28, UNITIZED PANEL SYSTEM. PROVIDE WIREWAYS AS NEEDED TO ENTER CPI <br /> 3/4"C,2#8,#8 ,#1 OG A1C 1/2HP,1/2HP,120V1 P W PANEL WITH BRANCH CIRCUITING. REFER TO PANEL SCHEDULE ON SHEET o <br /> I - POWER PLAN J 1 g PROVIDE OCCUPANCY CONTROLLED RECEPTACLE FOR HALF OF DUPLEX 12 a a a a a a a <br /> 1/4" = 1'-0" <br /> RECEPTACLE. <br /> 20 CPI UTILIZED ALL-IN-ONE PANEL SYSTEM COMBINING PANELS A, B, C, L AND <br /> o MAIN SWITCHBOARD MSB. <br /> a 21 JBOX FOR HARD WIRED LOW VOLTAGE LAVATORY FAUCET SYSTEM WITH <br /> 00 ELECTRICAL EQUIPMENT SCHEDULE TRANSFORMER. <br /> 00 <br /> GENERAL NOTES o <br /> " EQUIPMENT ELECTRICAL EQUIPMENT ELECTRICAL Q W <br /> A. PROVIDE GFCI PROTECTION FOR ALL 120V RECEPTACLES IN KITCHEN <br /> AREA z Q0 <br /> o B. ALL WIRES SHALL BE #12 AWG UNLESS NOTED OTHERWISE. PROVIDEo W Cy) <br /> z NO. OTY ITEM / DESCRIPTION VENDOR MODEL NUMBER V PH AMP KVA HP NO. OTY ITEM / DESCRIPTION VENDOR MODEL NUMBER V PH AMP KVA HP SEPARATE NEUTRAL WIRE FOR ALL LIGHTING CIRCUITS BACK TO LIGHTING - ® Q co <br /> �����, <br /> a CONTROL PANEL. E 0 <br /> A1C 1 CAPPUCCINO MACHINE (6 HEAD) CURIIS G3 PRIMO PCGT63099 (LIFT DOOR) 120V 1 15 1.800 F4 1 COMPUTER SYSTEM BOS COMPUTER XP BKO 120V 1 1.7 0.300 C. ALL 120V. RUNS LONGER THAN 100' SHALL BE #10 WIRE SIZE UNLESS 0 <br /> a. W A10 2 G4 DUAL 1.5 GALLON COFFEE BREWER CURTIS G4GEMTIF1OA399 120/208V 1 29 5.9 W F5 1 CCN-RECORDER/DVR/MONITOR NAVCO MCS16-10E-16 CAMERA SYSTEM, 120V 1 7.0 0.300 NOTED OTHERWISE ON PLANS. O <br /> �'� Q U <br /> w LL Al2 2 SINGLE WARMER STAND CURITS GEM51F099 120V 1 .8 0.09 CAMERA; CLINTON CE-VT988 LCD MONITOR D. WHERE WIRE SIZES ARE NOTED ON DRAWINGS, THAT SIZE SHALL BE J <br /> c A14 1 UGOLINI GRANITA MACHINE (3 BARREL) GRINDMASTER CECILWARE MT3ULBL 120V 1 15 1/2" O F11 1 UPS BATTERY BACKUP 120V THROUGH THE ENTIRE RUN UNLESS NOTED OTHERWISE. L ^ Q <br /> o �u�u� <br /> U A18 1 COUNTERTOP ICE DISPENSER W/ ICE MACHINE FOLLETT 15CI10OA-NW-NF-ST-00 115V 1 1 5 F12 1 PRINTER 120V E. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS ASu~y <br /> �� � �. W W W <br /> 3 A51 1 COFFEE TIMER FRANKLIN MACHINE PRODUCTS 151-1044 120V G2 1 CO2 SAFETY MONITORING LOGICO2/NUCO2 CO2 ALERT MK10 DETECTOR SET 2 A REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM � <br /> 131A 2 FROZEN BEVERAGE DISPENSER (3 FLAVOR) CORNELIUS 621360041 VIPER SHORT MERCHANDISER 230V 1 30.0 G6A 1 ICE MACHINE SCOTSMAN REMOTE PACKAGE <br /> F. THE CONTRACTOR SHALL COORDINATE THE EXACT MOUNTING LOCATION U_ U Q <br /> cai B2A 1 FOUNTAIN TOP MOUNT ICE MAKER 850 LB (CUBED) HOSHIZAKI KMD-901MRH 2O8V 1 10 O G6C 1 ICE MAKER REMOTE CONDENSING UNIT SCOTSMAN ERC311-32A REMOTE CONDENSER 208V OF ALL LIGHT FIXTURES, LIGHT SWITCHES, RECEPTACLES, <br /> I Z B2B 1 FOUNTAIN TOP MOUNT ICE MAKER 900 LB (NUGGET) SCOTSMAN N0922R-32 208V 1 15 O G8 1 WATER HEATER A.O. SMITH BTX-80 TELEPHONE/DATA OUTLETS, AND ANY OTHER DEVICE LOCATIONS SHOWN O <br /> zz Q ON THIS PLAN WITH THE ARCHITECTURAL FLOOR PLAN, ARCHITECTURAL <br /> 2 132C 1 ICE MAKER REMOTE CONDENSING UNIT (CUBED) HOSHIZAKI URC-91F 115V 1 7.5 Y G10A 1 WATER BOOSTER DUAL SURGE TANK KIT McCANNS 16-1517 115V 1 7 0.33 REFLECTED CEILING PLAN, AND ARCHITECTURAL INTERIOR ELEVATIONS. U Q <br /> O B2E 1 ICE MAKER REMOTE CONDENSING UNIT (NUGGET) SCOTSMAN ERC311-32 208-230V 1 60 Q G21 1 2 DOOR REACH-IN REFRIGERATOR TRAULSEN PRODUCTS G20010 115V 1 7.3 DEVICES NOT LOCATED ON THE ARCHITECTURAL DRAWINGS SHALL BE W <br /> COORDINATED WITH THE ARCHITECT IN THE FORM OF RFI (REQUEST FOR Cf) <br /> a B12 1 20-VALVE ICE/BEVERAGE DISPENSER SERVEND MDH-402-20 IC 20PB QT/KITS Ql/SL3/CLI, 120V m G22 1 OVEN HOOD CAPTIVE-AIRE 5424VHB 3'-8" LENGTH 115V 1 0.331INFORMATION). CONTRACTOR SHALL ASSUME THAT DEVICES ARE TO BE <br /> m LQ W/STD 12"ADAPTEMERCH.R <br /> INCL. 0051 9 FOR <br /> G54 1 CARBONATOR MCCANNS "BIG MAC" E-SERIES E400397 115V 1 6.5 0.90 0.33 MOUNTED CENTERED ON THE WALLS, SECTION OF WALLS, WINDOWS, ETC. <br /> HOSHIZAKI ADAPTER TOP 020005129 FOR OBER <br /> co <br /> B14E 1 FCB GRAPHIC FOR 52" CART (ILLUMINATED) RED ROOSTER 59"x45" TG1 1 MICROWAVE OVEN TURBO AIR TMW-1100E 120V 1 15 1.68 AND THAT ADDITIONAL MOUNTING BRACKETS AND ACCESSORIES SHALL BE <br /> °f APART OF THE BID PROPOSAL. <br /> N C2 3 CASH REGISTERS/POS RADIANT STANDARD 120V 1 15 TG3 1 FOOD WARMER HATCO FS3HAC-3626 AIR CURTAIN 120/208V 1 13.8 <br /> i C3 1 INTERCOM TO FUEL POSITIONS 3M D-120VPART 78-6911-4796-7 120V TG4 1 REFRIGERATED SELF-SERVICE DELI CASE STRUCTURAL CONCEPTS OASIS C037R 110/120V 1 15.33 G. REFER TO MECHANICAL CONTROLS DIAGRAM FOR ADDITIONAL SCOPE <br /> SERIAL 2470011634, 78-8117-3900-8. OF WORK, SUCH AS POWER FOR THERMOSTATS, AND OTHER WORK <br /> o W w/4 station card TG413 1 REFRIGERATED SELF-SERVICE ISLAND STRUCTURAL CONCEPTS OASIS FS1656R 6' CASE 208/204V 1 23.73 REQUIRED BY ELECTRICAL CONTRACTOR AND NOT SPECIFICALLY <br /> C5 1 SAFE TTDEL SERIES 4XL W/ STORAGE VAULT & TUBE VEN 20-22OV TG5A 1 WORKTOP REFRIGERATOR TURBO AIR TWR-60SD-D2 115V 1 8.9 0.33 <br /> MENTIONED IN ELECTRICAL DRAWINGS. Project Number <br /> N <br /> a Q C6A 1 LOTTO TERMINAL STATE LOTTERY COMMISSION 120V 1 15 TG6 1 VERTICAL CONTACT TOASTER ANTUNES VCT-2 9210907 120V 1 15 H. REFER TO ARCHITECTURAL DETAILS FOR INSTALLATION OF OUTLETS IN SPA16002.0 <br /> C7 1 TANK MONITOR EQUIPMENT VEEDEROOT VR-TLS 350 120V 1 15 TG7 1 CONVECTION OVEN W/MANUAL CONTROLS IMPERIAL HSICVE-2 208V 1 32 0.25 FIRE RATED WALLS. <br /> Jv <br /> W C18B 1 ICE CREAM NOVELTY CASE ICE CREAM VENDOR 4' CASE 120V O TG7A 1 OVEN 12-CHANNEL TIMER PRINCE 740-T12 120V 1 .083 I. ALL PERMANENTLY CONNECTED (HARD-WIRED) APPLIANCES SHALL BE Sheet Name <br /> o D2D 1 COOLER DOOR LED LIGHTS ANTHONY INTERNATIONAL OPTIMAX = TG8 1 CHILI AND CHEESE DISPENSER GEHL'S HOT TOP DUAL DISPENSER (BLACK) 120V 1 1.7 0.20 SERVED WITH DISCONNECTING MEAN WITHIN SIGHT OF THE UNIT, OR THE <br /> �' W D10 4 WALK-IN COOLER EVAPORATOR HEATCRAFT SEE SHEET Q1.2 TG10 1 REFRIGERATED CONDIMENT ISLAND WASSERSTROM 90-5/8"x42" 120V 1 SERVING CIRCUIT BREAKER IN THE PANEL SHALL BE CAPABLE OF BEING <br /> o QJ D10A 2 WALK-IN COOLER CONDENSING UNIT HEATCRAFT SEE SHEET Q1.2 TG35D 1 FREE STANDING BAKERY CASE HUSSMANN DCA244262 120V J.LOCKED IN OPEN POSITION AS REQUIRED PER NEC 422.31. POWER <br /> a V D11 2 WALK-IN FREEZER EVAPORATOR HEATCRAFT SEE SHEET Q1.2 TG37 1 ENERGY ZONE COOLER TRUE #GDM-10-HC-LD 115V 1 2 1.39 0.17 ANDEOUTLEFER OT REQUIREMENTS. <br /> a. IPMENT <br /> DRAWING SHEET E0.1 FOR POWER PLAN <br /> U <br /> a. D11A 1 WALK-IN FREEZER CONDENSING UNIT HEATCRAFT SEE SHEET Q1.2 C3 1 INTERCOM TO FUEL POSITIONS 3M D-120VPART 78-6911-4796-7 120V <br /> E2 1 ATM NCR SELFSERV 16 J SERIAL 2470011634, 78-8117-3900-8.11.1 K. FINAL EQUIPMENT LOCATION SHALL BE COORDINATED WITH ARCHITECT. <br /> VZ C5 1 SAFE - CASH VALIDATOR NKL V2RC15 120V 1 15 w/4 station card REFER TO DWG. Q1.1 FOR FIXTURE LOCATION. <br /> W 0 C5A 1 SAFE - COIN DROP NKL D8C AUTOBANK 120V 1 15 Sheet Number <br /> C51) 1 PRINTER NKL OM-100 120V 1 15 <br /> 0 O G8 1 ELECTRIC WATER HEATER A.O. SMITH DVE-52 <br /> TG10 1 REFRIGERATED CONDIMENT ISLAND SHOPCO 90-3/4"x43-3/4" 120V 1 E2mO <br /> i <br /> i� <br />