Laserfiche WebLink
CLASS 1, B C-31,33 C-35,37 C-39,41 <br /> DIVISION 2 IL <br /> L❑CATI❑N <br /> FUTURE EV <br /> TANK <br /> VENTS A,IR/WA TER NIT Elm 2.4KVA,12OVJP2W <br /> ® FUTURE EV� a <br /> O -FUTURE EV ROBISON <br /> �AACLEAN AHI FAIR ENGINEERING, INC <br /> VAN.- EV VANPOOL EV VANPOOL EV <br /> 01 40TH AVE W.,SUITE <br /> CLEAN AIRl CLEAN AH/ CLEAN AIR I C-23 194LYNN WOOD,A 98036 02 <br /> VAPFOOL VANPOOL I EV VAPFOOL Ev 3/4»C,1#4,#4N,#10G 206364-3343 TEL <br /> 20 <br /> CONTACT:TYLER BEAM <br /> °CLASS 1, B <br /> DIVISI❑N 1 <br /> LOCATI❑N <br /> (TYP.) QROFESS/n <br /> G-32,34 21 G-38,40 <br /> � <br /> 1 �� <br /> 77 p <br /> z <br /> T oRrvE_niRu <br /> CAR WASH w No. E-21545 m <br /> ExR Exrr <br /> o ED <br /> © 4 T9TF`OF C <br /> F EL DISPENSER 9 F L DISPENSER 10 S'Z ' <br /> Seal <br /> 1 92KVA,208/12OV2P W 1. 2KVA,208/12OV2P3W <br /> G-37,39 G-26,28 <br /> bp <br /> 0 Ill <br /> FUEL DISPENSER 7 F L DISPENSER 8 <br /> 1.92KVA,208/12OV2P W 1. 2KVA,208/12OV2P3W <br /> G-25,27 G-31,33 <br /> F L:_�IS ENSER 5 <br /> �J0 1 K A, 8/12OV2P3W 2 4 <br /> 0 4/NLEAbED TURBINE 1 O11 11 � t . <br /> K VA,208 V3P4W <br /> 77 <br /> ° FEL DISPENSER 6 <br /> FT > <br /> G 2,4,6 G-13,15 19 1. 2KVA,208/12OV2P3 ,, <br /> T <br /> - <br /> ,21 � <br /> G <br /> I <br /> UNLEADED <br /> TURBINE SUMP C <br /> CLA 1 DIVISI❑N 1 EA FUEL. �Dl�E�SER 3 L _J <br /> (TYP,) 1.92 120V2P3W ° <br /> G-22 - <br /> Oo° UNLEADED EMIUM #1 <br /> CL S 1, DIVISION ° 2.74KVA,20 3P4W FUEL DISPENSER 4 <br /> A ARE VEEDER ROOT 0 RFILL ALARM 1.92KVA,208/12OV2P3W <br /> z <br /> G-1,3 G-7,9 0 a- <br /> F G /. > <br /> G o <br /> -8,10,12 UNL PREM <br /> W <br /> CLASS 1 DIVISION 2 <br /> z <br /> L P M DISPENSING AREA DIESEL TURBIN #1 o <br /> 2.74KVA,208V3 4W o o J <br /> DI L 10 CAR WASH YPAD. m <br /> G-14,16,18 5/SD1. Q <br /> 2 TYP. FUEL DISPENSER <br /> ULL DISPENSER 1 1.92KVA,208/120V z <br /> 1.92KVA,208/12OV2P3W0 <br /> Z rn <br /> a0 w N <br /> 0 m O \ <br /> A TANK FILL z m oCD <br /> w CLASS 1 DIVISI❑N <br /> _ aaa <br /> 1 (TYP.) p o => >> aaa <br /> � a <br /> U <br /> NEC CLASS I , DIVISION All HAZARDOUS AREA PLAN <br /> CL 1" = 20' <br /> T ❑ <br /> 00 117177 <br /> 12M <br /> 00 <br /> 0 <br /> M a SITE POWER PLAN <br /> NOTE: THE LAST 2 FEET (MINIMUM) OF CONDUIT ENTERING TANK W <br /> NEC HAZARDOUS AREAS <br /> 3 SUMPS, DISPENSER SUMPS AND VENT TRANSITION SUMPS SHALL BE 1" = 20' N O <br /> z PVC COATED RIGID STEEL CONDUIT. <br /> CL TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK - FILL OPENING) � W C`) <br /> A > Lo <br /> EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: ��- � Q <br /> 0 ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN 1� <br /> ELECTRICAL SITE NOTES THE DIVISION 1 OR 2 CLASSIFIED LOCATION OR WITHIN ZONE 1 OR 2 CLASSIFIED LOCATION. _ I 0 0) <br /> EXTENT OF CLASS 1 GROUP D DIVISION 2 LOCATION: O Q <br /> N 13 OVERFLOW ALARM/STROBE: 3/4" C WITH 3#10 FROM J-BOX FOR OVERFILL ALARM/STROBE AND ACKNOWLEDGEMENT Q U <br /> o O FEEDER REQUIREMENTS PRIORIT UTILITY VERIFY WITH PG&E UTLITIES FOR ALL POWER, TRENCHING, CONDUIT AND SWITCH (FOR U/G TANK) TO VEEDER-ROOT CONTROLS IN C-STORE ELECTRICAL AREA. MOUNT J-BOX AT 14' ABOVE FROM A 18 INCHES <br /> CONNECTION AND LWITH NNAAHOR ZONTALLRADIDUISSOFF510EETET O <br /> W FINISH GRADE. <br /> 0 2 PROPOSED LOCATION OF EXTERIOR CLOSET FOR METER/MAIN SWITCHBOARD. PROVIDE LEVEL 6" CONCRETE PAD FOR FROM A TIGHT FILL CONNECTION. Q <br /> 0 O THE MAIN SERVICE PANEL. 14 TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK SELF-PAY PEDESTAL: PROVIDE 3/4" POWER CONDUIT & WIRE AND 1" COMMUNICATIONS CONDUIT WITH PULLSTRING _ VENT-DISCHARGING UPWARD) U, CO ~ U <br /> r O < co W W w <br /> � <br /> o O PROPOSED ROUTING OF UNDERGROUND SERVICE CONDUCTORS. EC TO VERIFY ROUTING, TRENCHING, AND ALL OTHER O EXTENT OF CLASS 1 GROUP D DIVISION 1 LOCATION: <br /> �uG <br /> i 15 PROPOSED LOCATION OF UTILITY TELEPHONE PEDESTAL. VERIFY WITH TELCO UTILITY FOR ALL COMMUNICATION, WITHIN 5 FEET OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. c <br /> a REQUIREMENTS WITH UTILITIES PRIOR TO BID. U <br /> � TRENCHING, CONDUIT AND FEEDER REQUIREMENTS PRIOR TO BID. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: LLQ <br /> 4 UNDERGROUND POWER FEEDERS TO CARWASH PANEL. SEE ONE-LINE DIAGRAM 16 PROPOSED ROUTING OF UNDERGROUND TELEPHONE CONDUITS. EC TO VERIFY ROUTING, TRENCHING, AND ALL OTHER SPACE BETWEEN 5 FEET AND 10 FEET OF OPEN END OF VENT, EXTENDING IN ALL <br /> 0 REQUIREMENTS WITH TELCO UTILITY PRIOR TO BID. DIRECTIONS. < O D <br /> 5 UNDERGROUND COMM/DATA CONDUITS TO CARWASH: TWO 3" PVC CONDUITS WITH PULLROPE. PROVIDE 6" STUB-UP 17 LOCATION OF MAIN TELEPHONE BOARD. EC TO COORDINATE WITH TELCO UTILITY FOR ALL TELCO BOARD DIMENSIONS O TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (REMOTE PUMP - OUTDOOR) U Q <br /> 0 BY WALL IN OFFICE AND IN CARWASH. AND REQUIRMENTS PRIOR TO BID. EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: W <br /> a ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN Cn <br /> O AIR/WATER UNIT: IDENTIFY AND EXTEND EXISTING UNDERGROUND CONDUITS TO AIR/WATER STATION AND YARD LIGHT. 18 PROVIDE AND MAINTAIN ALL REQUIRED WORKSPACE, ACCESS TO WORKSPACE AND HEADROOM ABOUT ELECTRICAL 10 FT HORIZONTALLY FROM ANY EDGE OF PUMP.. <br /> m PROVIDE POWER CONNECTIONS. EQUIPMENT. PROVIDE PROTECTION FROM PHYSICAL DAMAGE FOR ELECTRICAL EQUIPMENT IN WAY OF BOLLARDS OR EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br /> OTHER BARRIERS IN ACCORDANCE WITH LOCAL AHJ. EC TO COORDINATE PROTECTION SCHEME WITH <br /> o WITHIN 3 FEET OF ANY EDGE OF PUMP, EXTENDING HORIZONTALLY IN ALL DIRECTIONS. <br /> rn 7 ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF POINT OF SUPPLY FOR TELEPHONE AND ELECTRICAL UTILITY ARCHITECT/PROJECT MANAGER. VERIFY EQUIPMENT UP TO 18 INCHES ABOVE GRADE LEVEL, EXTENDING 10 FT HORIZONTALLY IN ALL DIRECTIONS <br /> N SERVICE. METER LOCATIONS ARE SUBJECT TO APPROVAL OF UTILITY SERVICE PROVIDER. DIMENSIONS PRIOR TO ROUGH-IN. FROM ANY EDGE OF PUMP. <br /> z 8 NOT USED. 19 FUTURE SOLAR AREA CONNECTION: 1" C WITH PULL-STRING FOR FUTURE SOLAR CONNECTIONS AT CANOPY ROOF. OD TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - PITS) <br /> F= O MONUMENT SIGN: PROVIDE POWER CONDUIT & WIRE TO PANEL AND LIGHTING CONTROLS; 2#10, 1„ EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION:C. PROVIDE ANY SPACE WITHIN AND UNDER DISPENSER PIT OR CONTAMINANT. <br /> N Project Number <br /> 9 NOT USED. 20 DISCONNECT IF NOT INTERNAL TO MONUMENT SIGN. <br /> a 10 MULTI-PRODUCT DISPENSER ELECTRICAL. REFER TO FUEL PLANS FOR MORE INFORMATION. SPA16002.0 <br /> 0 21 CANOPY LIGHTING & SIGNAGE: PROVIDE POWER CONDUIT & WIRE TO PANEL AND LIGHTING CONTROLS. O TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) <br /> N 11 ALL UTILITIES SHALL BE BURIED AT A MINIMUM DEPTH OF 24" BELOW GRADE UNLESS OTHERWISE INDICATED. EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: Sheet Name <br /> W SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED IN ANSI/UL 87, <br /> p 12 EMERGENCY SHUTOFF: 3/4" C WITH 2#10 FROM SITE EMERGENCY SHUT-OFF (ESO) SWITCH TO CASHIER CONTROL CENTER "POWER OPERATED DISPENSING DEVICES FOR PETROLEUM PRODUCTS." <br /> inAT CASHIER STATION. VERIFY FINAL LOCATION WITH ARCHITECTURAL AND FUEL DRAWINGS. AN ESO TO BE LOCATED WITHIN CONDUIT BURIAL DEPTHS <br /> 0 100' OF EACH DISPENSER. POWER UTILITY: AS REQ'D O TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) SITE POWER <br /> w SITE ELECTRICAL: 24" <br /> a EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: PLAN DETAILS <br /> WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE FROM <br /> TELCO UTILITY: AS REQ'D <br /> (1) THE DISPENSER ENCLOSURE OR (2) THAT PORTION OF THE DISPENSER <br /> ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. <br /> z EC TO PROVIDE WARNING <br /> z <br /> Y RIBBON IN ALL ELECTRICALOG TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - OUTDOOR) <br /> a CONDUIT TRENCHES. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br /> 0 UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 20 FEET HORIZONTALLY OF ANY Sheet Number <br /> EDGE OF ENCLOSURE. <br /> 0 <br /> 0E6m 1 <br /> W <br /> L� <br />