My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
I
>
INDUSTRIAL
>
927
>
1600 - Food Program
>
PR0544598
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 10:30:21 AM
Creation date
8/11/2020 3:06:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0544598
PE
1625
FACILITY_ID
FA0025347
FACILITY_NAME
HIGH WATER BREWING TAPROOM AND BREWERY
STREET_NUMBER
927
STREET_NAME
INDUSTRIAL
STREET_TYPE
WAY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
927 INDUSTRIAL WAY
P_LOCATION
02
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOOR GENERAL NOTES <br /> ZL 1. ALL INTERIOR AND EXTERIOR DOORS SHALL: <br /> DOOR SCHEDULE STOREFRONT SCHEDULE A. HAVE 1/2"MAX.HIGH THRESHOLD(ABOVE <br /> FLOOR AND LANDING ON BOTH SIDES). <br /> PANEL DETAILS SIZE FRAME DETAILS B. HAVE A MAX.DOOR OPENING EFFORT OF 5 LBS. <br /> C. BE EQUIPPED WITH SINGLE EFFORT,NON- <br /> THRESHOLD/ FIRE HDWR. NO. TYPE WIDTH HEGHT MATERIAL FINISH HEAD JAMB SILL COMMENTS GRASPING TYPE HARDWARE(I.E.LEVER) ARCHITECTURE <br /> NO. TYPE WIDTH HEIGHT THICKNESS CORE FRAME HEAD JAMB SILL RATING GROUP COMMENTS S1 A 12'-1" 8'-0" ALUMINUM CLEAR ANODIZED CENTERED BETWEEN 34"AND 44"ABOVE THE <br /> S2 B 16-0" 8'-0" ALUMINUM CLEAR ANODIZED FLOOR.2016 CBC SECTIONS 11 B-404.2.5, <br /> l OOA G 3'-0" 7'-0" 2" STEEL STEEL - PANIC METAL GATE S3 B 161-011 8'-0" ALUMINUM CLEAR ANODIZED 11 B-404.2.9,AND 11 B-404.2.7. <br /> 10013 F 16-0" T-0" 2" STEEL STEEL - METAL ROLLING GATE S4 B 161-011 81-011 ALUMINUM CLEAR ANODIZED 2. ALL EXIT DOORS SHALL BE OPERABLE FROM INSIDE <br /> 101A C 14'-0" 8'-0" 6" STEEVINSUL. STEEL - INSULATED SLIDING BARN DOOR S5 C 12'-4" 8'-0" ALUMINUM CLEAR ANODIZED WITHOUT SPECIAL KNOWLEDGE OR USE OF A KEY. <br /> 101B A 3'-0" 8'-0" 1 3/4" GLAZING ALUM. - PANIC TEMPERED GLAZING S6 D 221-911 81-011 ALUMINUM CLEAR ANODIZED SECTION 1008.1.8 ARCHITECT <br /> 101 C C 1141-0" 8'-0" 6" STEEVINSUL. STEEL - INSULATED SLIDING BARN DOOR 3. PROTECT PREFINISHED SURFACES AND REPAIR ANY <br /> 101 D A T-0" T-10" 1 3/4" GLAZING ALUM. - PANIC TEMPERED GLAZING NJ ASSOCIATES <br /> 105A B 3'-0" 7'-0" 1 3/4" 12'-1 V.I.F.TEEVINSUL. H.M. - DAMAGE. 22769 N BENDER ROAD <br /> +/- " <br /> 105B D 5'-0" 9'-0" 1 3/4" STEEVINSUL. STEEL - INSULATED SLIDING BARN DOOR AT COOLER,REFER TO MANUF.REQUIREMENTS 4. DOORS,HARDWARE AND THRESHOLDS SHALL ACAMPO CA 95220 <br /> 110A B 3'-0" T-0" 1 3/4" WD ALUM. - 314" 4 EQ. EQ. EQ. COMPLY WITH ACCESSIBILITY REQUIREMENTS. 209.727.2040 <br /> 111A B 13'-0" 71-011 1 3/4" WD H.M. 45 MIN. www.njaarchitecture.com <br /> 111B B 3'-0" 7-0" 1 3/4" WD ALUM. - N 5. WHERE CLOSERS ARE INDICATED,THE OPENING <br /> FORCE IS TO BE SET AS FOLLOWS: <br /> 112 B 3'-0" T-0" 1 3/4" WD H.M. - A. EXTERIOR DOORS-5 LBS. CLIENT <br /> 201A E 10'-0" 7'-0" 1" STEEL STEEL 45 MIN. RATED OVERHEAD ROLL-UP DOOR B. INTERIOR NON-RATED DOORS-5 LBS. <br /> 201B D 3'-0" 7'-0" 1 3/4" H.M. H.M. 45 MIN. J 6 HIGH WATER BREWING <br /> 201C E 12'-0" 10'-0" 1" STEEL STEEL 45 MIN. OVERHEAD ROLL-UP DOOR o 7. ALL INTERIOR AND EXTERIOR DOORS TO HAVE A 10" <br /> LL u_i SMOOTH,UNINTERRUPTED BOTTOM SURFACE OR <br /> 203 A T-0" T-10" 1 3/4" GLAZING ALUM. - TEMPERED GLAZING <br /> x PROVIDE A 10" HIGH KICK PLATE.2013 CBC SECTION <br /> 204 E 12'-0" 10'-0" 1" STEEL STEEL - OVERHEAD ROLL-UP DOOR o 113313.2 <br /> 205 3'-0" 7'-0" 1 3/4" - CO o <br /> LU <br /> 8. RIGHT HAND LEAF OF PAIR DOORS TO BE ACTIVE <br /> U.O.N. PROJECT <br /> T T T 9. ALL FIRE RATED DOORS AND FRAMES(ASSEMBLIES) HIGH WATER BREWING <br /> SHALL HAVES'LABEL OR PROVIDE SMOKE SEAL 927 INDUSTRIAL WAY <br /> WITH'S' LABEL. LODI CA 95240 <br /> PANEL WIDTH , STOREFRONT - TYPE A <br /> 10. TEMPERED GLASS WILL OCCUR AT THE FOLLOWING <br /> A9.0 = <br /> PANEL 2"FRAME-,, PANEL 2" FRAME PANEL WIDTH 1/4" 1'-0" LOCATIONS WHEN ALL APPLY:A. AREA OF GLAZING IS GREATER THAN 9 SQ.FT. <br /> 4„ WIDTH 4„ WIDTH B. THE BOTTOM EDGE IS LESS THAN 18"ABOVE THE <br /> 16-0"V.I.F. FLOOR <br /> C. THE TOP EDGE IS MORE THAN 36"ABOVE THE <br /> EQ 4 EQ EQ EQ EQ FLOOR <br /> D. A WALKING SURFACE WITHIN 36" <br /> HORIZONTALLY OF THE GLAZING <br /> _ - <br /> _ _ J <br /> / w w <br /> LU w = Z <br /> _ = w a <br /> z 1" INSUL.GL. z FLUSH PANEL Q FLUSH METAL INSULATED <br /> ` PANELS FLUSH PANEL HARDWARE REQ, <br /> T •` o <br /> CO <br /> A.F.F. CD <br /> A.F.F. 1. ALL RATED DOORS TO BE POSITIVE LATCHING <br /> A B C D 2. ALL EXIT DOORS SHALL BE OPERABLE FROM INSIDE <br /> WITHOUT USE OF A KEY. <br /> T T T T T <br /> 3. ALL OPERATING SWINGING DOORS TO HAVE LEVER <br /> HANDLES U.O.N. <br /> PANEL WIDTH <br /> z STOREFRONT - TYPE B 4. PROVIDE STOPS AT ALL LOCATIONS WHERE DOOR <br /> WILL STRIKE PARTITION,U.O.N. <br /> PANEL WIDTH PANEL A9.0 1/4"=1'-0" 5. PROVIDE COORDINATOR AT ALL RATED DOUBLE <br /> WIDTH DOORS. <br /> 6. DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM <br /> AN OPEN POSITION OF 90 DEGREES,THE TIME <br /> EQ. EQ. EQ. 3'-3" REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 <br /> Lu DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM <br /> _ = N <br /> W <br /> z w w 7. ALL KEYED DOORS SHALL BE APPROVED BY OWNER <br /> FOR KEYED SEQUENCE. <br /> z FLUSH METAL z FLUSH METAL <br /> a PANELS < PANEL �� �� J <br /> o <br /> Lu <br /> S <br /> A.F.F. A.F.F. q �x, U-) <br /> bo <br /> E F G o DOOR SIGNAGE <br /> Lu <br /> Lu <br /> 1. PROVIDE SIGNAGE THAT COMPLIES WITH CBC SECTION ARCHITECTS STAMP <br /> 1008.1.8.3.A READILY VISIBLE SIGN POSTED ON THE <br /> DOOR TYPES EGRESS SIDE OF THE DOOR OR ADJACENT TO THE A <br /> DOOR STATING:THIS DOOR TO REMAIN UNLOCKED �Sagrc <br /> WHEN BUILDING IS OCCUPIED.THE SIGN SHALL BE IN v �, <br /> 1/4"-1-0 <br /> 3 - LETTERS 1" HIGH ON ACONTRASTING BACKGROUND. -� JQHNAVIERRA <br /> STOREFRONT TYPE C � <br /> * C-35199 <br /> A9.0 1/4"=1'-0" 2. EACH GRADE LEVEL EXTERIOR EXIT DOOR SHALL BE <br /> IDENTIFIED WITH A TACTILE EXIT SIGN WITH THE WORD Lp 10-31-2019 <br /> RENEWAL <br /> "EXIT". 9T DATE Q- <br /> +/-22'-9"V.I.F. OF CAS-XF� <br /> EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR <br /> AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO <br /> EQ. EQ. 4 EQ. EQ. EQ. EQ. EQ. HAVE A VISUAL EXIT SIGN SHALL BE IDENTIFIED BY A <br /> TACTILE EXIT SIGN WITH THE WORDS"EXIT ROUTE" REVISIONS <br /> No. Description Date By <br /> 1 PLAN CHECK#1 5.XX.18 EM <br /> BARN DOOR TRACK NOTES <br /> LL <br /> 0 1. 450 LB WEIGHT MAX <br /> co 2. BE SURE TO ORDER HARDWARE BEFORE BEGINNING <br /> FABRICATION OR INSTALLATION WORK. Project No.: 17043 <br /> 3. ALWAYS USE THE INSTRUCTIONS INSIDE THE Drawn By: JWNS <br /> PACKAGING PROVIDED BY THE MANUFACTURER,AS <br /> T T T T T T T THE MANUFACTURER RESERVES THE RIGHT TO MAKE Checked By: <br /> TECHNICAL CHANGES OR MODIFY INFORMATION <br /> WITHOUT PRIOR NOTICE. <br /> 4. ALL TECHNICAL DRAWINGS AND DOCUMENTS <br /> STOREFRONT - TYPE DCONTAIN EXAMPLES OF THE ASSEMBLY. NOT FOR CONSTRUCTION <br /> 4 5. AT ALL TIMES,EXECUTION AND INSTALLATION MUST <br /> A9.0 1/4"=1'-0" BE UNDERTAKEN BY QUALIFIED PERSONS. PERMIT SET <br /> 6. NEVER EXCEED THE MAXIMUM WEIGHT OR THE 04.04.18 <br /> MAXIMUM DIMENSIONS RECOMMENDED BYTHE <br /> MANUFACTURER. <br /> ALWAYS BE SURE TO INSTALL THE PRODUCT <br /> CORRECTLY USING THE RIGHT FASTENERS FOR YOUR <br /> MATERIALS. <br /> 7. NEVER USE ANY SPRAY LUBRICANT ON THESE DOOR&STOREFRONT SCHEDULES <br /> PRODUCTS. <br /> a <br /> M <br /> N <br /> (V <br /> W <br /> A9 *0 <br /> O <br /> N <br /> R <br />
The URL can be used to link to this page
Your browser does not support the video tag.