My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GOLDEN VALLEY
>
16514
>
1600 - Food Program
>
PR0544910
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2023 11:15:33 AM
Creation date
8/12/2020 8:15:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0544910
PE
1625
FACILITY_ID
FA0025530
FACILITY_NAME
IN-N-OUT BURGER #346
STREET_NUMBER
16514
STREET_NAME
GOLDEN VALLEY
STREET_TYPE
PKWY
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16514 GOLDEN VALLEY PKWY
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
750
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAINTENANCE MANUAL <br /> THIS MANUAL TO BE KEPTAT THE CONTROLLER LOCATION ATALL TIMES. <br /> IRRIGATION SYSTEMS: <br /> 1. A UTOMA TIC CONTROLLER TO BE CHECKED MONTHL Y, B Y LANDSCAPE <br /> MAINTENANCE FOREMAN AND CHECKED WEEKLY BY MAINTENANCE CREW <br /> LEADER, TO PROVIDE OPTIMUM PLANT GROWTH AND WATER <br /> CONSERVATION. (SMART CONTROLLER IN USE, CHECK ELECTRICAL POWER <br /> ONLY). <br /> 2. LANDSCAPE MAINTENANCE CONTRACTOR, TO CHECK ALL SYSTEMS ONCE <br /> PER MONTH BY TURNING ON THE SYSTEMS MANUALLY. 3 @ <br /> 3. LANDSCAPE MAINTENANCE CONTRACTOR TO VISUALLY CHECK ALL SYSTEMS <br /> EVERY WEEK, DURING MAINTENANCE OF LANDSCAPE. jolt SEE NOTE: <br /> 0 COIL ADDITIONAL 9-INCHES OF TUBING <br /> 4. ALL IRRIGATION FILTERS AT THE WYE STRAINER (AT THE BACKFLOWDEVICE) NOTES: NOTES7 IN VALVE BOX TO FACILITATE <br /> AND ALL FIL TERS A T THE DRIP IRRIGA TION VAL VES TO BE CLEANED 0 USE TEFLON TAPE ON ALL PVC <br /> MAINTENANCE. <br /> MONTHLY OR AS NEEDED. TO PVC CONNECTIONS; NO <br /> PIPE DOPE ALLOWED. FIELD INSTALLED BELOW GRADE PIPE <br /> @) <br /> 5. CHECK RAIN SHUT OFF DEVICE AT THE BEGINNING OF THE RAINY SEASON 0 SET PERIMETER HEADS 4"-6" 11-11 FE1 . CONNECTIONS SHALL BE THREADED <br /> AND RE-CALIBRATEAS NEEDED. MAKE SURE DEVICE IS CLEAN AND FREE OF FROM CURBS AND WALKS AND k <br /> :tri PVC OR GLUED PVC. <br /> ANY DEBRIS, AND IN GOOD WORKING ORDER. 6"-12" FROM VERTICAL t El I I I I MICROTUBING MUST BE BURIED AT <br /> OBJECTS SUCH AS FENCES 1-11 M I I I-I I M I M I 1- 7 <br /> 6. BACKFLOW DEVICE TO BE VISUALLY CHECK ON A MONTHLY BASIS. TESTAND LEAST 6" BELOW GRADE AND THE <br /> AND WALLS, ETC. I I MI I I-- =1 I I EEI I EEI I I <br /> 1 ri 11 1 <br /> RE-CERTIFY ANNUALLY ASPER ALL CODES AND ORDINANCES. 0 ONLY USE BOTTOM INLET OF 1/2" IN TURF AREAS MICROTUBING MUST BE SECURED BY <br /> 7. SCHEDULEALL SPRAY SYSTEMS TO RUN ONLYBETWEEN THE HOURS OF 2:00 HEAD I MI I I- AND 1" IN PLANTER A STAKE. <br /> AM AND 9:00 AM. PLACE HEAD PERPENDICULAR MAXIMUM LENGTH OF MICROTUBING <br /> C\1 <br /> 8. ON MONTHLY BASIS FLUSH ALL DRIP SYSTEM LINES AND CHECK VALVE TO GRADE. 10 SHALL BE 10'-0". <br /> BOXES TO SEE THAT THEY DRAIN PROPERLY. CLEAN OUTANYDEBRIS, MUD <br /> OR PLANT GROWTH ANNUALLY. LEGEND LEGEND <br /> 9. TWICE A YEAR CHECK ALL QUICK COUPLERS AND MAKE ALL REPAIRS AS 1. SIDEWALK, CURB, ETC. 4 1. FINISH GRADE 6. TRIPPLE SWING JOINT <br /> NECESSARY, REPLACE PEA GRAVEL IN VALVE BOXES AS NEEDED. 2. POP-UP SPRAY HEAD PER LEGEND 2. 7" ROUND BOX (RAINBIRD VB-7RND) 7. PVC LATERAL LINE <br /> 10. COVER OR PROTECT ALL BACKFLOW DEVICES DURING FREEZING WEATHER. 3. FINISH GRADE. 5 3. MULCH PER PLANTING PLAN. 8. PVC SCH 40 TEE OR ELL <br /> 11. OWNER TO PROVIDE FOR A WATER AUDIT, EVERY FIVE YEARS FROM 4. TRIPLE SWING, SIZE PER INLET (KBI 4. MULTI-OUTLET EMISSION DEVICE PER LEGEND 9. LANDSCAPE FABRIC <br /> MODEL: TSA OR EQUAL) 5. 1/4-INCH TUBING: POLYETHYLENE DISTRIBUTION 10. 12" MIN. 3/4"WASHED GRAVEL. <br /> OPENING OF STORE. 5. PVC LATERAL LINE TUBING RAIN BIRD XQ-XXXX 11. DIFFUSER BUG CAP: RAINBIRD DBC-025 <br /> 12. 1/4-INCH TUBING STAKE: RAINBIRD TS-025 <br /> POP-UP BUBBLER - PALM TREE ULTI-OUTLET EMITTER- TREE BUBBLER <br /> SCALE: NO-SCALE SCALE: NO-SCALE <br /> LEGEND <br /> 1. ROOT BALL 5. BOWSMITH MULTI-EMISSION DEVICE (1 PER TREE), <br /> 2. TREETRUNK PERLEGEND <br /> 3. TREE CANOPY 6. EMITTER VALVE BOX. <br /> 4. ROOTWELL DEVICE- NO BUBLR 7. 1/4" DISTRIBUTION TUBING, BURRY 2" BELOW FG <br /> (2 PER TREE) 8. STAKE AND BUG CAP PER DETAIL. <br /> MUTLI-OUTLET EMISSION DEVICE LAYOUT- TREE SCALE: NO SCALE <br /> LANDSCAPE ARCHITECT: <br /> OSCAP,, <br /> , <br /> A <br /> 77 11&0 <br /> BPA enewal Date <br /> LANDSCAPE ARCHITECTS f25/2018 <br /> Date <br /> OF CA <br /> BRANDON PETRUNIO &ASSOCIATES, INC. <br /> LANDSCAPE ARCHITECTS <br /> T: (424)235-8940, M: (951)312-9943 <br /> E: brandon@bpalas.com <br /> REVISIONS GHA PROJECT NO- ----- CIVIL ENGINEER: LANDSCAPE <br /> DEVELOPER: Underground Service Aler7) Z� I MSL �,oFESS/O/V IN-N-OUT BURGER <br /> . LAI' `5� <br /> IN-N-OUT BURGER ORE Call: Toll Free ENGINEERING,, INC - "GI 16514 GOLDEN VALLEY PARKWAY <br /> 13502 HAMBURGER LANE A- CIVIL ENGINEERS AND LAND SURVEYORS SPECIALIZING IN SITE DEVELOPMEN I m IRRIGATION DETAIL <br /> BALDWIN PARK, CA. 91706 Arch itectu re/Devel opm en t 402 WEST ARROW HWY., SUITE 4, SAN DIMAS, CA. 91773 No. 38382 m LATHROP, CA 95330 <br /> CONTACT: KORI SEKI COD Parkway Plaza I OW) 305-2395 FAX (909) 305-2397 <br /> (626) 813-8275 TWO WORKING DAYS 14110 Dallas Parkway, Ste. 300 C/V1 SHEET 2 <br /> BEFORE YOU DIG Dallas Texas 75254 OF- C <br /> Ph: (972) 239-8884 10-25-18 <br /> ZL Fax: (972) 239-5054 MARK R.C.E. 38382 DATE L1Dm2 <br /> 'N vmm-mm C91W <br />
The URL can be used to link to this page
Your browser does not support the video tag.