WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GOLDEN VALLEY
>
16514
>
1600 - Food Program
>
PR0544910
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2023 11:15:33 AM
Creation date
8/12/2020 8:15:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0544910
PE
1625
FACILITY_ID
FA0025530
FACILITY_NAME
IN-N-OUT BURGER #346
STREET_NUMBER
16514
STREET_NAME
GOLDEN VALLEY
STREET_TYPE
PKWY
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16514 GOLDEN VALLEY PKWY
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
750
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
For Health Hazard Applications ES-SS009Job Name –––––––––––––––––––––––––––––––––––––––––––Contractor ––––––––––––––––––––––––––––––––––––––––––––Job Location –––––––––––––––––––––––––––––––––––––––––Approval –––––––––––––––––––––––––––––––––––––––––––––Engineer –––––––––––––––––––––––––––––––––––––––––––––Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––Approval –––––––––––––––––––––––––––––––––––––––––––––Representative –––––––––––––––––––––––––––––––––––––––– <br />SS009QT <br />Series SS009Stainless Steel Reduced PressureZone Assemblies <br />Sizes: 1⁄4" – 1" (8 – 25mm) <br />Series SS009QT Stainless Steel Reduced Pressure Zone <br />Assemblies provide protection of the potable water supply in accor- <br />dance with national plumbing codes and water authority require- <br />ments. Series SS009 can be used in a variety of health hazard <br />installations whenever the downstream liquid is of a composition <br />which may damage bronze material or it is desirable to eliminate <br />trace elements of lead and copper. Typical applications are: <br />Industrial or plant use, medical/diagnostic equipment, reverse <br />osmosis systems, carbonated beverage machines, breweries/dis- <br />tillers, paper and pulp industry, chemical plants and aggressive <br />atmospheres. The SS009 series features two in-line independent <br />check valves, captured springs, replaceable check seats, corrosion <br />resistant internal parts and a hydraulically operated differential pres- <br />sure relief valve. All sizes are constructed with NPT body connec- <br />tions and are standardly furnished with vandal resistant EZ-TC Test <br />Cocks. Series SS009QT's are furnished with 316 Stainless Steel, <br />full port, investment cast, quarter turn ball valve shutoffs with 304 <br />Stainless Steel tee handles. <br />Features <br />• Investment Cast 316 Stainless Steel Assembly <br />for corrosion resistance <br />• All wetted valve components — test cocks, ball valve <br />shutoffs, pipe nipples, body and cover, check modules and relief <br />valve assembly are made from "Lead Free" Stainless Steel or <br />Plastic construction <br />• Bolted on, top entry single access cover for ease <br />of maintenance <br />• Modular check construction featuring nonreversible checks with <br />captured springs for simplified servicing <br />• Top mounted vandal resistant EZ-TC test cocks provide easy <br />access for testing <br />• Stainless Steel EZ-TC test cocks include dust covers to protect <br />the threads from dirt, dust and insects <br />• EZ-TC Test cocks eliminate the need for tools and test fittings <br />• True line sized check modules open further allowing dirt and debris to <br />pass freely through the valve reducing fouling problems <br />• Check and Relief Valve Seats are replaceable without the use of <br />special tools <br />• Internal relief valve for right and left hand installations <br />Specifications <br />A reduced pressure zone assembly shall be installed at each noted <br />potential health hazard location to prevent backflow due to back- <br />siphonage and/or backpressure. The assembly shall consist of an <br />internal pressure differential relief valve located in a zone between <br />two independently operating positive seating check modules with <br />captured springs and silicone seat discs. Seats and seat discs shall <br />be replaceable in both check modules and the relief valve, without <br />the use of special tools. There shall be no threads or screws, in the <br />waterway, exposed to line fluids. Service of all internal components <br />shall be through a single access cover secured with stainless steel <br />bolts. The assembly shall include two resilient seated isolation <br />valves, four top mounted vandal resistant test cocks with dust cov- <br />ers, a protective stainless steel wye strainer with a 20 mesh screen <br />and an air gap fitting. The assembly shall consist of an investment <br />cast 316 Stainless Steel body and cover with Series 300 Stainless <br />Steel test cocks, 316 Stainless Steel Ball Valve Shutoffs with PTFE <br />Seat blowout proof 304 Stainless Steel Stems, and 304 Stainless <br />Steel Tee Handles. The assembly shall meet the requirements of <br />ASSE Standard 1013, AWWA Standard C511. Assembly shall be a <br />Watts Regulator Company Series SS009QT. <br />Test Cock No. 3 <br />Test Cock No. 4 <br />R.P. Zone <br />Water Outlet <br />Test Cock <br />No. 2 <br />First Check <br />Module <br />Assembly <br />Second <br />Check <br />Module <br />Assembly <br />Relief Valve Assembly <br />EZ-TC-SS <br />Test Cocks <br />Now Available <br />WattsBox Insulated Enclosures. <br />For more information, send for literature ES-WB. <br />LEAD FREE* <br />*The wetted surface of this product contacted by consumable water <br />contains less than one quarter of one percent (0.25%) of lead by weight. <br />Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, <br />please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications,or materials with- <br />out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. <br />ES-SS009.qxd 11/3/09 8:47 AM Page 1
The URL can be used to link to this page
Your browser does not support the video tag.