Laserfiche WebLink
GAS WATER HEATER SCHEDULE PK1000 PACKAGE FROM PLUMBING FIXTURES SCHEDULE <br /> STORAGE RECOVERYGAS NATIONAL WHOLESALE <br /> UNIT # QUANTITY MANUF. & MODEL NO. LOCATION SERVICE CAPACITY @ 100-AT OUTLET CW HW INPUT ITEM DESCRIPTION WASTE VENT CW HW REMARKS APPROVALS <br /> TEMP. INLET OUTLET <br /> GALLONS GPH CFH NATIONAL WHOLESALE CONTACT: NEW CONSTRUCTION (888)-444-4435 Architecture / Development <br /> WH-1 2 BRANDFORD WHITE ROOF DOM. HW 100 197 140° 1y2" 1 ,999 NATIONAL WHOLESALE PART NUMBER: DESCRIPTION: ___ <br /> COMMANDER SERIES TOWER y2" 199MEETS CPC 411.2 AND <br /> WC-1 WATER CLOSET 4" 2" 1" TOTO WATER CLOSET CT705EN, FLOOR MOUNTED, FLUSH VALVE, SIPHON JET ACTION, ELONGATED BOWL, COTTON, VITREOUS CHINA, <br /> UCG-10OH-199-3N 1.28 GALLONS PER FLUSH, TOTO TET1LA32#CP ECOPOWER FLUSH VALVE, KOHLER K-4731-C-0 OPEN FRONT SEAT LESS COVER. CAL-GREEN 5.303.3.1 14901 Quorum Drive <br /> REMARKS: T&P RELIEF VALVE, TACO 008 CIRC. PUMP, 1/25HP, 115V, SINGLE PHASE, Suite 300 <br /> » (1) JP877 TRIPLE MANIFOLD KIT TO CONNECT HEATERS. SEE ACCESSIBLE WATER >, MEETS CPC 411.2 AND Dallas Texas 75254 <br /> WATTS N36 M1 VACUUM RELIEF VALVE OR EQUAL, ATMOSPHERIC VENT 6 DIA. MANIFOLD KIT CONTENTS LISTED BELOW. WC-2 CLOSET 4.> 2 1 --- TOTO A.D.A. WATER CLOSET CT705ELN. SIMILAR TO WC-1, EXCEPT A.D.A. HEIGHT. (NOTE: ROUGH-IN ALSO HIGHER.) CAL-GREEN 5.303.3.1 <br /> Ph: (972)239-8884 <br /> QUANTITY I DESCRIPTION QUANTITY DESCRIPTION " Fax: (972)239-5054 <br /> KOHLER BARDON K-4904-ET, 0.125 GPF, WHITE, VITREOUS CHINA, MOUNT ON WALL AT A.D.A. HEIGHT. FLUSHVALVE TOTO ECOPOWER MEETS CPC 412.1 AND <br /> WATER AND GAS PIPING PACKAGE U-1 ACCESSIBLE URINAL 2" 1-1/2" 3/4" --- TEU1UN12#CP, 0.125 GPF, HANDS FREE. CAL-GREEN 5.303.2 ISSUE RECORD <br /> 1 DETA20 6 1" CxF DIE UNION CORIAN COUNTERTOP WITH INTEGRAL SINK, TOTO TEL5LS10#CP ECOPOWER FAUCET WITH SMART SENSOR, 0.5 GPM, 10 SECOND DATE DESCRIPTION <br /> 1 009 PUMP 2 3 4" BLK IRON TEE <br /> SHUT-OFF VALVE SCHEDULE 1 2" 1/2" OPERATION WHILE ACTIVATED, THERMAL MIXING FAUCET. SET TO 105F. BRASS CRAFT #G23341XC1 1/4-TURN ANGLE STOPS, MEETS CALIFORNIA GREEN <br /> 1 1" BRASS FLANG SET 4 3 4" BLK 90 L-1 ACCESSIBLE LAVATORY 2" 1-1/4" / / BRASS CRAFT #B1 S/S BRAIDED 1/2" FAUCET CONNECTORS, SUPPLIES, & 17 GAUGE P-TRAP WITH PRO FLOW SNAP-ON SHIELD. BUILDING CODE 0.5 GPM 0-22N2018TOISSUED FORPERMIT <br /> MAN UF. & 2 1" S BALL VALVES 3 3/4" X 28" GAS FLAX MxM <br /> ITEM DESCRIPTION MODEL N0. SIZE SERVICE REMARKS: PROVIDE ON (OR IN) 1 1" S CHECK VALVE 3 3 4" BLK GAS COCK SS-1 SERVICE SINK 3" 1-1/2" 3/4" 3/4" CUSTOM FABRICATED SINK BY REF. CONTRACTOR SHALL PROVIDE FISHER #8261 FAUCET (2.2 GPM): ECCENTRIC STOPS, LONG MEETS CALIFORNIA GREEN <br /> SPOUTS, PAIL HOOK, WALL BRACE, VACUUM BREAKER, K-9147 DRAIN, 2" CAULK TYPE, DRAIN WITH STRAINER AND 5-0" HOSE. BUILDING CODE 2.2 GPM <br /> V-1 1/4 TURN - ANGLE BRASSCRAFT 1/2" CW HW HAND SINKS AND LAVATORIES 6 THERMO 3 3/4" BLK IRON UNION <br /> / SINK FURNISHED KES. CONTRACTOR SHALL INSTALL AND PROVIDE CHICAGO # 116.224.AB.1 FAUCET WITH SWING GOOSE NECK <br /> G23341X C1 6 1/2" CXFTG FEMALE ADPT 3 3/4" C 3 BLK IRON NIPPLE HS-1 HAND SINK �° °' SPOUT MOD GN2AHBAB AND 0.5 GPM NONE-AERATING SPRAY MOD #E2805-5AB WITH INTERNAL MIXING VALVE BRASS CRAFT MEETS CAL-GREEN <br /> 4 1X1/2" CxC TEE 3 3/4" BLK CAP 2 1-1/4 1/2 1/2 # � 5.303.3.4.2 <br /> V-2 MULTI TURN - ANGLE BRASSCRAFT 1/2" CW / FW R.O. FILTER AND TEA / COFFEE SUPPLY 1 1" C 90 10 3 8" ATR #G23341XC1 1/4-TURN ANGLE STOPS, BRASS CRAFT #B1 S/S BRAIDED 1/2 FAUCET CONNECTORS. SET MIXED WATER TO 110F. <br /> OCR09X C1 / <br /> MUELLER POTATO PEELING, COMP SINK, AND FD-1 FLOOR DRAIN <br /> 3 1-1/2" X 1" CxC TEE 3 3/8" 128R 3" /2" ___ ___ J R SMITH 2O05Y-BO6NB, GRATES COVERING THE FLOOR DRAINS SHALL HAVE SPACES NO GREATER THAN 1/2" <br /> 107-453NL SELF-SERVE & DRIVE-THRU SODA <br /> V-3 BALL VALVE 1/2" CW/HW/FW 2 1-1/2" X 1/2" CxC TEE 3 1-1/4" 138R (U.N.O.) 1-1 WIDE, PROVIDE TRAP PRIMER CONNECTION ON RESTROOM DRAINS <br /> MUELLER <br /> 1 1-1/2" CxC TEE 6 1" X 3/4" GAL BELL REDUCER FD-2 FLOOR DRAIN 3 1 -1/2 --- --- <br /> REF (RESTAURANT EQUIPMENT FABRICATORS) STAINLESS STEEL IN-N-OUT FLOOR THROUGH WITH GRATE. <br /> V-4 BALL VALVE 107-454NL 3/4" CW / HW 3-COMP SINK (TURBOWASH) 1 1-1/2" S CHECK VALVE 6 1" X 2" GAL NIPPLE 41" X 47"(I.D.) RECTANGULAR; 14 GAUGE STAINLESS STEEL FLOOR SINK WITH 16 GAUGE STAINLESS STEEL GRATE. <br /> 1 1-1 2 S BALL VALVE 3 1 X 6 BLK NIPPLE HAND SINK WALL MOUNT ADVANCE TABCO 7-PS-49) STAINLESS STEEL END CAP ON TOP AND SIDE. LARGE SIZE SINK BOWL 16 x14 X8 REVISION RECORD <br /> NOTES: ALL PLUMBING FIXTURES AND KITCHEN SHALL HAVE INDIVIDUAL SHUT-OFF VALVES FOR 2 1-1/2" CxC 90 3 1" BLK TEE HEAVY GAUGE TYPE 304 SERIES STAINLESS STEEL WALL MOUNT, K59 OMIT (FAUCET) K472 REVISION (SINGLE HOLE). CONTRACTOR SHALL <br /> SERVICE PER PLUMBING CODE. USE "V-1" OF APPROPRIATE SIZE, U.N.O. 6 1" S BALL VALVES 6 1" X 1-1/2" BLK NIPPLE HS-2 HAND SINK 2" 1-1/4" 1/2" 1/2" INSTALL AND PROVIDE CHICAGO # 116.224.AB.1 FAUCET WITH SWING GOOSE NECK SPOUT MOD # GN2AHBAB AND 0.5 GPM NONE-AERATING <br /> PROVIDE SHUT-OFF VALVES WITH LEVER HANDLES WHEN AVAILABLE. 2 4 <br /> 3/4" SWT X 3 " HOSE 3 5/8" FLEX W/ 1/2M X 36" SPRAY MOD #E2805-5AB, WITH INTERNAL MIXING VALVE, BRASS CRAFT #G23341XC1 1/4-TURN ANGLE STOPS, BRASS CRAFT #B1 S/S <br /> / BRAIDED 1/2" FAUCET CONNECTORS. SET MIXED WATER TO 110F. <br /> VENT PACKAGE FS-1 FLOOR SINK 3" REF (RESTAURANT EQUIPMENT FABRICATORS) STAINLESS STEEL IN-N-OUT FLOOR SINK WITH GRATE. <br /> 2 6" CAP 0 4" STORM COLLAR (U.N.O.) 1-1/2" _-- --- 12" X 12" SQUARE BY 6" DEEP; 14 GAUGE STAINLESS STEEL FLOOR SINK WITH 16 GAUGE STAINLESS STEEL GRATE. <br /> ADD-ALTERNATE: BOOSTER PUMP 0 4" CAP 2 6" STORM COLLAR RD-1 ROOF DRAIN --_ ___ ___ JR SMITH 1010 WITH METAL RECEIVERS, HOLD DOWN CLAMP KIT, & GALV. CAST IRON DOME. SEE PLANS FOR OUTLET SIZES. <br /> 0 6" 90 0 4" X 1' PIPE <br /> MAN UF. & 0 6" TEE 0 4" X 5' PIPE OD-1 OVERFLOW DRAIN JR SMITH 1080 (WITH 2" DAM) WITH METAL RECEIVERS, HOLD DOWN CLAMP KIT, & GALV. CAST IRON DOME. SEE PLANS FOR <br /> MODEL N0. 0 4" <br /> DESCRIPTION SIZE REMARKS: X 6" INCREASE 0 4" X 6' PIPE --- --- --- OUTLET SIZES. <br /> DUPLEX BOOSTER PUMP SYSTEM ITT - 2ST: 1-1/41-1/2 FULLY AUTOMATIC SYSTEM, VARIABLE 0 4" FLASHING 0 4" X 6" PIPE HB-1 HOSE BIBB (INDOOR) ___ _-- 3/4" --- WOODFORD #26-PC (POLISHED CHROME) HOT OR COLD WATER (SEE FLOOR PLAN), ANTI-SIPHON VACUUM BREAKER, WALL FAUCET <br /> AQUABOOST - 6 SPEED DUPLEX PUMPS2 6" X 3' PIPE WITH METAL WHEEL HANDLE <br /> 2 6 FLASHING WOODFORD #B67-AL COLD WATER, FREEZELESS, AUTOMATIC DRAINING WALL FAUCET, DOUBLE CHECK BACKFLOW PREVENTER, <br /> 0 4" PIPE COLLAR 2 6" X 2' PIPE HB-2 HOSE BIBB --- --- 3/4 --- ANODIZED ALUMINUM BOX <br /> MAX. FLOW (PER PUMP) DESIGN PT. MAX. TDH DESIGN PT. NPSHR VOLTAGE / PH / HP 2 6" PIPE COLLAR 2 6" X 5' PIPE TRENCH DRAIN <br /> TD-1 TRASH ENCLOSURE 4 2 ___ ___ <br /> ZURN 12" WIDE REVEAL TRENCH DRAIN, MODEL #Z882. LENGTH AS SHOWN ON PLAN (P2.0). <br /> 130.6 GPM 83.3 GPM 111.4 FT 80.9 FT 8.3 FT 208V / 3 PH / 5 HP 1 ST20VC EXPANSION TANK, ASME RATED PROFESSIONAL SEAL <br /> CO-1 CLEANOUT (ON WALKS) 4» --- --- --- J.R. SMITH #4020 SERIES WITH POLISHED BRASS TOP (-PB) AND PROFESSIONAL <br /> ADJUSTMENT, RATED FOR MEDIUM WHEELED LOADS. <br /> NOTES: PROVIDE ADD-ALTERNATE BID TO ADD IF BUILDING PRESSURE IS DETERMINED TO BE TOO LOW. (1) 008BF5 TACO RECIRC PUMP r <br /> PROVIDE WITH EXPANSION TANK AS RECOMMENDED AND SIZED BY MANUFACTURER. (1) 1BRF 1" BRASS FLANGES CC-2 CLEANOUT (LANDSCAPE) 4" --- --- - EXTEND PIPE 1 A.F.G. AND PLUG. PROVIDE PLASTIC HANDHOLE (APPROX. 8"0 x 12 DEEP) WITH COVER NOTING C.O. OR BLANK. , Q <br /> CONTACT: MR. BRYAN EISELT, OSLIN NATION, AT 800-293-2506 x154 OR beiselt@onco-tx.com (1) ET8115C TIMER FOR PUMP <br /> TRASH AREA MIXING FISHER #2445 (SHORT SPOUT) FAUCET WITH INTEGRAL VACUUM BREAKER. PROVIDE HEAT TRACE AROUND PIPES FROM GRADE UP TO <br /> FAUCET-1 FAUCET --- --- 3/4" 3/4" FAUCET. INSULATE PIPES WITH 1" FIBERGLASS AND JACKET. ENCLOSE WITHIN ACCESS PANEL/BOX. REFER TO ARCHITECTURAL DETAIL. <br /> GROUND CLEANOUTS (GCO) AND TWO-WAY CLEANOUTS (TWCO): <br /> REFER TO THE CIVICS PLANS AND SPECIFICATIONS FOR REQUIREMENTS BFPD-1 BACK FLOW --- --- 1/2" - WATTS 007, DOUBLE CHECK VALVE ASSEMBLY <br /> OF GCO'S AND TWCO'S THAT ARE LOCATED IN DRIVE-WAYS AND IN PREVENTION DEVICE <br /> PARKING AREAS. IN LANDSCAPE AND WALKWAYS AROUND THE REDUCED PRESSURE <br /> BUILDINGS THEY SHALL COMPLY WITH "CO-1" AND "CO-2" IN BFPD-2 ZONE ASSEMBLY --- --- ** - WATTS 009, ** SIZE SAME AS LINE SIZE. D <br /> CONTRACTOR SHALL PROVIDE WATER HAMMER PLUMBING FIXTURES SCHEDULE ACCORDING TO LOCATION. <br /> ARRESTORS BY SIOUX CHIEF, PRECISION PLUMBING PROVIDE 8x8 SST ACCESS PANEL REDUCED PRESSURE <br /> PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH (CENTERED AT 84" AFF) AT EACH VALVE BFPD-3 ZONE ASSEMBLY --- --- 3/4" - WATTS 009, STAINLESS STEEL CONSTRUCTION, USED FOR CARBONATORS <br /> PISTON AND 0-RING CONSTRUCTION, HAVING PDI #WH- / WATER HAMMER ARRESTOR LOCATION IN WATER HEATER SIZING CALCULATIONS <br /> 201, ASSE #1010 AND ANSI #A112.26.1 M RESTROOMS; ONE AT EACH WC WITH REDUCED PRESSURE <br /> CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL INDIVIDUAL CONTROL. BFPD-4 ZONE ASSEMBLY --- --- 1" - WATTS LF-009 FOR WATER TEMP 33° TO 180°., USED FOR HIGH PRESSURE WASHER <br /> POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE CLACULATING BTU OF KITCHEN GAS WATER HEATER <br /> WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE 190 GPH X 60 X 11 = 125,400 BTU MXV-1 MIXING VALVE --- --- 3/4" 3/4" SYMMONS "MAXLINE" MODEL 5-230-CK-FS 76PM - FOR PRESSURE WASHER <br /> UNITS AS SHOWN ON THE DRAWINGS AND/OR PER THE THERMAL EFFCIENCY = 80% <br /> TABLES SHOWN ABOVE. PROVIDE ACCESS PANEL FOR 8.33 LBS/GAL. OF WATER = 11.1 (ROUND OFF -11) FLUSH VALVE TRAP PRECISION PLUMBING PRODUCTS engineering consultants <br /> SERVICING OR REPLACEMENT, WHERE REQUIRED. TP-1 PRIMER ___ ___ 1/2 PPP #FVP-1VB WITH VACUUM BREAKER 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> PROVIDE PIPE REDUCER WHERE REQUIRED. 75% (THERMAL EFFICIENCY I rtmassociates.com 1 972.387.3500 <br /> BTU INPUT = 125,400 (REQUIRED) NON-FLUSH VALVE PRECISION PLUMBING PRODUCTS <br /> PDI TP-2 TRAP PRIMER 1/2 PPP OREGON #1, PART PO-500INSTALL <br /> T SIZE BTU INPUT = 399,998 (PROVIDED) <br /> PDI i TSTA DARDSRANDI A RPZ �-NOTE: TWO WATER HEATERS PROVIDED AT 199,999 BTUs EACH 1 MATCH TOWER ROOF PROTOTYPE VERSION <br /> SIZE 2 3 (TYP.) URBAN DESIGN <br /> "A" � MANUFACTURER'S RECOVERY OF 197 GPH EACH EQUALS A TOTAL 394 GPH @ 100° RISE. 1" CW SUPPLY FROM <br /> O <br /> INSTRUCTIONS 1 <br /> t M <br /> WATER FILTER SYSTEM <br /> WC APPLICATION QTY. CONSUPTION (GPH) SEE FLOOR PLANS AND REFER TO ARCH. PROJECT NAME <br /> RISER DIAGRAM. 6"0 6"0 DETAILS FOR PLMBG. <br /> SINGLE FIXTURE SINGLE WC OR UR CW ONLY LAVATORIES 4 4 X 2.5 = 10 "Y" STRAINER REQUIREMENTS I N-N-OUT <br /> PDI PIPE FIXTURE FIXTURE UNIT TABULATION SERVICE SINK 1 1 X 10 = 10 OFF 0 0 2 STAINLESS STEEL RPZ <br /> SIZE SIZE UNIT LOAD FIXTURE COLD HOT DRAIN LINE - O (ABOVE SERVICE SINK) TOWER ROOF PPCAL VENTING EVERY 3' <br /> BURGER <br /> WHA- A 1/2" 1-11 VALVE WATER CLOSET 10 -- HAND SINKS 4 4 X 5 = 20 0 0 0 WITH FULL SIZE DRAIN VERTICALLY & 5 HORIZONTALLY 1 <br /> LINE, TERMINATE DRAIN <br /> TRASH AREA FAUCET 1 1 X 10 = 10 LINE AT FLOOR SINK G G 7"W.C. LOW PRESSURE G <br /> WHA- B 3/4" 12-32 TANK WATER CLOSET 5 -- SODA EQUIPMENT <br /> MIXING VALVE POTATO WASH AREA 1 1 X 2 = 2 SEE FLOOR PLANS WITH CODE REQUIRED LATH RO P <br /> WHA- C 1" 33-60 URINAL 5 -- AIR-GAP 1�4" 1y" <br /> / / 2-COMP SINK (POTATO SINK) 1 1 X 48 = 48 0 0 0 z CHECK VALVE (TYP) <br /> WHA- D 1-1 4" 61-113 LAVATORY SINK 1.5 1.5 o THERMOMETER BALL VALVE (TYP) <br /> WHA-EF <br /> 1-1/2" 114-154 JANITOR'S SINK 3 3 2-COMP SINK (PREP SINK) 1 1 X 10 = 10 03 S/S PIPING AND FITTING 0 w RECIRC PUMP AIR RELEASE CALIFORNIA <br /> 0 0 0 BETWEEN BEVERAGE `�' y4 y4» VALVE <br /> WHA- 2" 154-330 SHOWER/BATHTUB 2 2 3-COMP SINK (UTENSILS) 1 1 X 75 = 75 EQUIPMENT AND BACKFLOW �' X 1 1 �` <br /> TURBO WASH @ 3-COMP SINK 1 1 X 5 = 5 PREVENTER (NO COPPER c' HI � � -- 16514 GOLDEN VALLEY PKWY <br /> PIPING ALLOWED) 3 4"HWR 140E HOT WATER RETURN <br /> TOTAL CONSUMPTION = 175 GPH REQ'D © 100°F RISE FLOOR SINK <br /> THERMOMETER 6' 6 / LATHROP, CA 95330 <br /> TOTAL SINGLE SERVICE TOTAL I - <br /> CONSUMPTION UTENSILS 80° RISE GPH REQUIRED (TYP) 1-1/2 HW 1_1/2" 1-1/2"CW <br /> Op HAMMER ARRESTORS 190 GPH X 0.80 = 152 GPH C�? 80' RISE 1"HW 1"HW <br /> OO 05 BEVERALE: NOT TO SALGE SYSTEM B.F.P. , _ , 1-1/2"Hw <br /> WATER HEATER SELECTED PROVIDES - 394 GPH 100'F RISE z 140E HW TO 1-1/2"CWLo <br /> C) X g UNDER ROOF �FF ir F_ e - - - <br /> VALOVEDON ROUGH-IN New AMTROL EXPANSION TANK <br /> WATER HEATER SIZING �NP)TRIC UNION <br /> SCALE: NOT TO SCALE v) GAS COCK (TYPICAL) <br /> 06 - - - - - - - SIZED FOR THREE WATER NmNmOUT <br /> FILTERED WATER SUPPLY VENT & C.O. REFER TO PLAN FOR 6 DIRT LEG SEDIMENT HEATERS. SECURE TO WALL <br /> DOWN IN PARTITION DRAIN SIZE. TRAP (TYPICAL) �� OR SUSPEND FROM SLAB I \BURGER@ <br /> WHERE SHOWN ON PLAN PER SMACNA STANDARD <br /> Cn <br /> BACKFLOW PREVENTER 1/2" MIN. C.W. SUPPLY SEISMIC STRAP Q <br /> A.S.M.E. RATED TEMP & I I GOD BLESS AMERICA <br /> ADAPTER AND TUBING PER <br /> (AVOID DIRECT CONNECTIONS PRESS. RELIEF VALVE. FULL NOTE: INSTALL WATER HEATERS IN <br /> w <br /> INOB'S REQUIREMENTS TO TO PREVENT FOREIGN A C UNIT SIZE DISCHARGE TO SEISMIC STRAP ACCORDANCE WITH MANUFACTURERS <br /> MATERIAL FROM ENTERING RECOMMENDATIONS. WATER HEATERS SHALL I Cn <br /> CUBER WATER INLET. OPEN-SITE OUTDOORS V) <br /> PRIMER VALVE) 6 BE CONNECTED WITH A REVERSE RETURN <br /> CUBERWH- PIPING LAYOUT AS SHOWN AND SHALL BE <br /> TRAP PRIMER ASSEMBLY DIELECTRIC UNION RELIEF DRAIN LINES AND WH-1 LOCATED AN EQUAL DISTANCE FROM EACH <br /> INDIRECT DRAIN OPEN 3y <br /> 11 O PROJECT NUMBER <br /> TO ATMOSPHERE AT TO BE MOUNTED EXPOSED 6 CONDENSATE DRAIN LINES OTHER WITH PROPER VENTING. <br /> UPPER END IN AN ACCESSIBLE <br /> SHALL BE LOCATED BEHIND 180641.001 <br /> ICE BIN ARRANGEMENT SHOWN IS LOCATION FOR PROPER WATER HEATERS (TYP) NOTE: REFER TO STRUCTURAL FOR SEISMIC <br /> CONNECT TO CUBEB SCHEMATIC. MODIFY TO MAINTENANCE. 3 A/C CURB BRACING REQUIREMENTS. WHEN REQUIRED. _ " _ '� SHEET TITLE <br /> AND ICE BIN DRAIN SUIT MANUFACTURER'S <br /> OUTLETS AS REQUIRED STANDARDS, MEET LOCAL PRECISION PLUMBING SEISMIC STRAP <br /> PROVIDE AIR GAP OF CODE REQUIREMENTS, AND PRODUCTS TRAP PRIMER 3„ T&P RELIEF DRAINS PLUMBING <br /> FLOOR IW TWICE PIPE DIAMETER ALL OTHER APPLICABLE VALVE W/INTEGRAL MIN. TO OUTDOORS SEISMIC STRAP <br /> CODES AND VACUUM BREAKER ROOF (SEE SHEET P3.0) SCHEDULES <br /> FLOOR SINK REQUIREMENTS. FOR o 0 <br /> INSTALLATION IN VACUUM BREATHER TYPE 'L' COPPER TUBING WITH <br /> MECHANICAL AND UTILITY PORTS WROUGHT COPPER FITTING <br /> ROOMS. PLATFORM (REF. A10.0) <br /> N PROVIDE FILTERED WATER ROUGH-IN AT TOP OF ICE MACHINE. INSULATE BELOW ROOF. USE TWO <br /> ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO 1/2" TRAP PRIMER 45°s IN LIEU OF 90°s FOR CLEANING. ROOF <br /> F1 <br /> %� 26 GAGE SHEET METAL PAN W/2" SHEET NUMBER <br /> Y .� SUIT CONDITIONS. VERIFY CONNECTIONS WITH MANUFACTURER. LINE TO DRAIN SLOPE TO APPROVED PROVIDE 1-1/2" DRAIN FROM PAN (SEE P5.0 AND P4.0) MINIMUM LIP, 1-1/2" DRAIN <br /> RECEPTACLE NOTE: PROVIDE SEISMIC STRAMPS, ONE ON <br /> ICE BIN SUPPLYTRAP PRIMER DETAIL (TP-2) CONDENSATE DRAIN DETAIL TTHE HE TOP THIRDIOF THE <br /> TTANK <br /> AND <br /> ONE ON <br /> GAS FIRED WATER HEATER SCHEMATIC <br /> z z O SCALE: NOT TO SCALE O d T SCALE: NOT TO SCALE O SCALE: NOT TO SCALE O 1 <br /> Cl- SCALE: NOT TO SCALE <br />