Laserfiche WebLink
PAINT GAS METER, REGULATOR, PIPING AND FITTINGS. REFER TO NOTES <br /> BELOW. GAS COCK <br /> BY GAS COMPANY (VERIFY) BY CONTRACTOR A.C.UNIT <br /> PRESSURE TEST COCK BUILDING WALL Architecture / Development <br /> GAS METER - CFH PIPE INCREASER UNION 17'-0" 14901 Quorum Drive <br /> CAPACITY SHOWN <br /> ON PLANS SEISMIC SHUT-OFF 6" DRIP/ Suite 300 <br /> � Dallas Texas 75254 <br /> Ph: <br /> STRAINER VALVE SV-1 DIRT LEG 2" (600 CFH) Da (972)2xas 74 <br /> SHUT-OFF VALVE <br /> Fax: (972)239-5054 <br /> GAS PIPE SHALL ENTER <br /> BUILDING LOW ON WALL ROOF ti ISSUE RECORD <br /> 47\ �GRADE OR V G� ,, DATE DESCRIPTION <br /> PAVEMENT FLOOR �� URBAN PROTOTYPE DESIGN <br /> � (680 CFH) <br /> PROVIDE 24x24 2 10-22-2018 ISSUED FOR PERMIT <br /> J\ PRESSURE REGULATOR SET AT 7" W.C. ACCESS PANEL <br /> SHUT-OFF VALVE VERIFYREQUIREMENTSREQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY, 1' <br /> INCLUDING MINIMUM WIDTH & CLEARANCES, IF ANY. CONTRACTOR SHALL PAY <br /> ALL GAS COMPANY FEES FOR INSTALLATION. 1Y4" (160 CF <br /> 2 y" (840 CFH) FRYERS <br /> GAS METER DETAIL RTU GAS CONNECTION G� ((120 <br /> TYP OFH5)EACH) <br /> 04 ,, <br /> SCALE: NOT TO SCALE O SCALE:NOT TO SCALE <br /> � P <br /> REVISION RECORD <br /> SV-1 SEISMIC SHUT-OFF VALVE STRAND EARTHQUAKE COMPANY PH: 310,473,2316 v F�1 PS G 3 �S <br /> IAPMO, EXCESS OF CA OSA VALVE MANUFACTURED BY GPS 0 G p�' G 1�G (1,239.9 CFH) 2 <br /> AND ANSI, LOS ANGELES PACIFIC SEISMIC PRODUCTS INC. 1 I bc @ N� v"�/ @ (399.9 CFH) GRILLES <br /> ORDINANCE #170641 -RR VALVE MOD. #314F (4") <br /> 5080 LISTED MAX. PRESS. 20-60 PSI. 1�pG�1 LPG �� �S (TYP(80 CFH-EACH) <br /> 3) CH <br /> P <br /> \ Q�� 2" <br /> (399.9 CFH) <br /> PLAN REVIEW NOTES 3" (1,419.9 CFH) <br /> AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE <br /> INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE �1I <br /> OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE 1)/4" <br /> EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL WH-1 (199.999 CFH) <br /> GAS PIPING JPER ORDINANCE 170,158) (INCLUDES <br /> COMMERCIAL A DLUONS AND TT WORK OVER $10,000.) <br /> SEPARATE PLUMBING PERMIT IS REQUIRED. <br /> � U U <br /> .I PROFESSIONAL SEAL <br /> p, <br /> WH-1 <br /> I � <br /> GAS PIPE IN CEILING SPACE 3" (1,599.9 CFH) Q <br /> SUPPORTED PER DETAIL TOTAL 1819.9 CFH <br /> T.D.L. = 267 FT <br /> BASED ON 2016 CPC <br /> CEILING FITTINGS LISTED FOR MANUAL GAS VALVE (TYP) C <br /> "CONCEALED LOCATIONS" IN <br /> CEILING SPACE AND WALLS NOTE: <br /> 1. EXPOSED GAS PIPE BEHIND FRYERS SHALL BE GALVANIZED <br /> EXHAUST HOOD STEEL GAS PIPE CONFORMING TO ASTM A 53. VERIFY IF _ D •�- <br /> INSTALL VALVES JUST ABOVE PERMITTED BY A.H.J. PRIOR TO ORDERING. <br /> 24"x24" PANEL IN ACCESSIBLE N <br /> GAS PIPE HEADER ALONG WALL BEHIND LOCATION 4" (1,819.9 CFH) 2. GAS PIPE WITHIN WALLS AND ABOVE INACCESSIBLE CEILINGS <br /> COOKING EQUIPMENT, APPROXIMATELY SHALL BE INSTALLED WITH FITTINGS LISTED FOR USE IN <br /> 12" ABOVE FLOOR, WITH SCREWED INSTALL AUTOMATIC GAS SHUT-OFF VALVE, "CONCEALED LOCATIONS." INSTALLATION SHALL COMPLY <br /> FITTINGS, SIZE AS SHOWN ON PLANS. FURNISHED BY KITCHEN EQUIPMENT SUPPLIER WITH THE 2016 CPC TABLE 1216.2(1) AND NFPA 54. <br /> PROVIDE QUANTITY AND SIZE OF (KES) AND INTERCONNECTED TO HOOD FIRE -klir <br /> CONNECTIONS AS REQUIRED FOR SUPPRESSION SYSTEM BY F.P.C. 3. PAINT EXPOSED GAS PIPE ABOVE ROOF BLACK. PAINT GAS k1r,.-t M <br /> EQUIPMENT BEING SERVED 17'-0" METER AND PIPE EXPOSED TO PUBLIC VIEW WHITE (I.E. engineering consultants <br /> TYPICAL PIPE SUPPORT MATCH ADJACENT BUILDING COLOR). 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> ANCHORED TO WALL. P rtmassociates.com 1 972.387.3500 <br /> G 4. PROVIDE DIRT LEGS AT ROOF EQUIPMENT, GRILLES, WATER <br /> MANUAL GAS �, GP��O G HEATERS, AND FRYER MANIFOLD. 18.GHAA.033 <br /> VALVE (TYP) FLEXIBLE APPLIANCE N 1,1 I, @ <br /> CONNECTOR FURNISHED BY KES �pG PROTOTYPE VERSION <br /> FLOOR AND INSTALLED BY CONTRACTOR URBAN DESIGN <br /> GAS LOAD SUMMARY <br /> TYPICAL 6" DIRT LEG <br /> TO 6" ABOVE FLOOR <br /> GAS PIPING MATERIALS (3)GAS GRILLES @ 80,000 BTU/H EA= 240 CFH PROJECT NAME <br /> ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT ACTUAL CONDITIONS. A-120 SCHEDULE 40 BLACKSTEEL ASSEMBLED WITH BLACK (5)GAS FRYERS ® 120,000 BTU/H EA= 600 CFH I N-N-O UT <br /> INSTALL PIPING HEADER IN WALL CAVITY PROVIDED, SEE ARCHITECTURAL. >, <br /> ATTACH RISER & HEADER TO WALL WITH 1" CLEARANCE BEHIND PIPE. MAKE ���2' MALLEABLE 125 LB. FITTING IN SIZES 2 OR SMALLER AND FOR AC-1 ® 180,000 BTU/H = 180 CFH BURGER <br /> FINAL CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURER. ,���� LARGER SIZES ASSEMBLED BY WELDING FITTING AS MANUFACTURED <br /> BY TUBE-TURN. AC-2 ® 180,000 BTU/H = 180 CFH <br /> GASAPPLIANCE 4,. AC-3 @ 220,000 BTU/H = 220 CFH <br /> O SCALE:NOT TO SCALE WH-1 2 @ 199,999 BTU/H EA = 399.9 CFH LATH RO P <br /> CALIFORNIA <br /> TOTAL= 1819.9 CFH <br /> 16514 GOLDEN VALLEY PKWY <br /> DISTANCE FROM METER TO MOST REMOTE CONNECTION 178'-6" LATHROP CA 95330 <br /> a° MULTIPLIER FOR LOSSES IN SYSTEM (X 1.50) X 1.50 <br /> TOTAL DEVELOPED LENGTH OF SYSTEM 267'-0" <br /> ANCHOR (EYE-SOCKET, STRAP, 7" WATER COLUMN LOW PRESSURE GAS PIPING SYSTEM. <br /> OR SIMILAR) <br /> TOTAL DEVELOPED LENGTH OF PIPING SYSTEM = 267 -0" <br /> NOTE: G GAS PIPING SYSTEM SIZED FROM THE <br /> BUILDING STRUCTURE MAY VARY PLUMBING CODE (2016 CPC) TABLE 1216.2(1) <br /> MATCH INSTALLATION TO BUILDING <br /> STRUCTURE REFER TO STRUCTURAL 4^ INNmOUT <br /> DRAWINGS FOR ATTACHMENT. COMPLY <br /> WITH MSS-SP-5B AND NFPA-24 \BURGER@ <br /> 3/8" ALL-THREAD ROD FOR GOD BLESS AMERICA <br /> <=4" PIPE. FOR LARGER PIPE <br /> SIZES SEE NFPA 13. <br /> HANGER - GRINNELL FIG. 69 GAS RISER DIAGRAM <br /> O I <br /> SCALE: NOT TO SCALE PROJECT NUMBER <br /> 180641.001 <br /> SHEET TITLE <br /> ON INSULATED PIPE. PROVIDE <br /> PIPE SUPPORT SHIELD. <br /> GAS RISER <br /> E DIAGRAM <br /> 0 <br /> PIPE HANGER DETAIL <br /> O SHEET NUMBER <br /> o SCALE: NOT TO SCALE <br /> m ¢ <br /> 00 <br /> P6mO <br /> ZZ <br /> � Ckf <br />