Laserfiche WebLink
Signal- and Motor-Rated Float Switch Matrix <br /> Signal-rated mechanical floats',(for control switch applications) <br /> P Modell Normally open Mechanical Yes r a j n/a n/a !, 2.00 in. 1.50 in. ! 0.`5U in. 2.00 in, <br /> N Model' Normally closed Mechanical Yes n;a n)a n/a L 2.00 in, 1.50 in.�0,50 in 2.00 in. <br /> Motor-rated floats'(for pump switch applications) „ <br /> B Model Normally open Mechanical No 120V 13A 112 hp 2.00 in b 2.50 in. 1.50 in. 4.00 in. <br /> 240V 13A 1 hp 3.00 in. 3.00 in. 1.50 in. 4.50 in. <br /> 4.00 in. 3.25 in, 1.50 in. 4.75 in. <br /> C Model Normally open Mechanical No 120V I 3A 1/2 hp 2.00 in. 3.00 in. 2.50 in. 5.50 in. <br /> 240V 15A 2 hp 3.00 in.° 3.50 in. 3.00 in. 6.50 in. <br /> 4.00 in. 4.00 in. 3.50 in. 7.50 in. <br /> 5.00 in. 4.50 in. 4.00 in. 8.50 in. <br /> 6.00 in. 5.25 in. 4.25 in. 9.50 in. <br /> G Model Normally open Mercury Yes 20V 15A 3/4 hp 2.00 in. 1.50 in. 3.00 in. 4.50 in. <br /> 240V 15A 2 hp 3.00 in.' 1.75 in. 3.00 in. 4.75 in. <br /> 4,00 in. 2.00 in. 3.50 in. 5.50 in. <br /> a.Suitable for use with VCOM and MVP <br /> b.Standard tether length <br /> Notes <br /> State:normally open or normally closed Drawdown <br /> The default state of a float-normally open or normally closed-refers to the contact Drawdown(in inches)refers to the difference in liquid level between a float switch's activation <br /> positrons in the float when the float is resting(down).Float switches have an internal contact. and deactivation points.Drawdown can be altered by adjusting the tether length of the float <br /> The terms"nomally open'(WO)and-nominally closed'(N/C)refer to the state of the float switch cord.When selecting float switches,keep in mind that any float switch that can directly <br /> switch contact in the down position.A normally open float switch has an open contact(610 in start and stop a pump(one that has no motor contactor in the control panel)Should have a <br /> the down position and a normally closed float switch has a closed contact(on)in the down drawdown capability,to avoid rapid cycling of the pump. <br /> position.Different panel functions require different types of float switches.Most applications Signal-rated or motor-rated <br /> require float switches that are normally open.One notable exception is the redundant off and Every float has a maximum amount of current it can handle.Exceeding these limits may cause <br /> low-level alarm function that requires a normally closed float switch,except with MVP and premature failure.Signal-rated or"control"floats are used to activate pump control panels <br /> vcob1 panels. and alarms.Only low amperage signals pass through these float switches,hence the float <br /> 'IR(intrinsically safe relay) switch is°signal-rated."All Orenco panels that use motor contactors can use signal-rated float <br /> Approved for use with intrinsically sate,Class 1.Division 1 applications,where reliable float switches.In some systems,a float switch is used to directly start and stop a pump.In this <br /> switch operation with very low current is requiredapplication,the current that is running the pump passes through the float Switch as well,and <br /> the float switch must be"motor-rated."in most instances,a motor-rated float switch can be <br /> used as a signal float switch. <br /> NTD-MF-MF-1 Orenco Systems®Inc.,814 Airway Ave.,Sutherlin,OR 97479 USA - 800-348-9843-541-459-4449-www.orenco.com <br /> Rev.2.0,°02/16 <br /> Page 2 of 2 <br />