My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2804
>
2200 - Hazardous Waste Program
>
PR0513781
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2020 10:42:31 AM
Creation date
8/17/2020 3:05:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0513781
PE
2226
FACILITY_ID
FA0009349
FACILITY_NAME
DIESEL PERFORMANCE INC
STREET_NUMBER
2804
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14343001
CURRENT_STATUS
01
SITE_LOCATION
2804 E FREMONT ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQU I N Environmental Health Department <br /> CC LJ N T Y------- <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DIESEL PERFORMANCE INC 2804 E FREMONT ST, STOCKTON August 17,2020 <br /> Universal Waste qq <br /> 719 CCR 66273.38 Failure of UW handler to transfer UW to the appropriate destination facility ❑V ❑R ❑COS <br /> 720 CCR 66273.31(a) UW handler caused improper disposal of UW ❑V ❑R ❑COS <br /> 721 CCR 66273.8(b) Conditionally exempt small quantity UW generator caused improper disposal of UW ❑V ❑R ❑COS <br /> Appliance Recycler <br /> 801 HSC 25211.4 Failure to obtain Certified Appliance Recycler certification(CAR) ❑V ❑R ❑COS <br /> 802 HSC 25211.2,25211.3 Failure of a CAR to provide docs that materials that require special handling have been removed ❑V ❑R ❑COS <br /> 803 HSC 25212 Failure of a CAR to properly remove and dispose of all materials that require special handling ❑V ❑R ❑COS <br /> Other Violations <br /> 3010 Seebelow Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 3020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 3030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 3050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 CCR 66265.31 Facility not maintained to minimize the release of a hazardous waste. <br /> OBSERVATION: A small puddle of used oil was observed on top of a blue metal 55 gallon drum of used oil <br /> beneath the pump. <br /> REGULATION GUIDANCE:A hazardous waste generator must maintain and operate its facility to minimize the <br /> possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous <br /> waste constituents to air, soil, or surface water which could threaten human health or the environment. <br /> CORRECTIVE ACTION: The violation was corrected during the inspection by wiping up the oil spill. No further <br /> action is required to correct this violation. <br /> This is a repeat violation, Class II. <br /> 303 CCR 66265.33 Failed to maintain all communication or alarm systems, spill control, or decontamination equipment. <br /> OBSERVATION: Secondary Containment Pallet for the used anti-freeze drum was observed with standing liquid <br /> inside. <br /> REGULATION GUIDANCE:All facility spill control equipment shall be maintained as necessary to assure its proper <br /> operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the spill pallet into proper working order by removing the liquid in the secondary <br /> containment and placing in the proper waste container. Provide a corrective action statement to the San Joaquin <br /> County Environmental Health Department within 30 days. <br /> This is a repeat violation, Class II. <br /> FA0009349 PR0513781 SCO01 08/17/2020 <br /> EHD 22-02 Rev.9/20/2019 Page 4 of 7 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.