GENERAL NOTES <br /> 1. CONSIDERATION WILL NOT BE GRANTED FOR ANY ALLEGED MISUNDERSTANDINGS OF THE AMOUNT OF WORK TO <br /> BE PERFORMED. TENDER OF PROPOSAL SHALL CONVEY FULL AGREEMENT TO THE ITEMS AND CONDITIONS <br /> INDICATED ON THE DRAWINGS. SHOULD THE CONTRACTOR FIND DISCREPANCIES OR OMISSIONS IN THE CONTRACT <br /> DOCUMENT OR BE IN DOUBT AS TO THE INTENT THEREOF, THE CONTRACTOR SHALL OBTAIN CLARIFICATION FROM <br /> THE ARCHITECT AND/OR THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING HIS PROPOSAL FOR WORK. <br /> o 0 <br /> 2. T. G. C. SHALL FIELD VERIFY THE EXACT EXISTING SPACE CONDITIONS, DIMENSIONS AND COLUMN SPACING PRIOR 0 <br /> TO CONSTRUCTION AND INFORM ARCHITECT IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND BETWEEN DRAWINGS <br /> AND SITE CONDITIONS. ANY CHANGES OR REWORK DUE TO UNREPORTED DIFFERENCES SHALL BE AT T. G. C.'S 0 <br /> EXPENSE. <br /> 3. ALL COLUMNS IN THE LEASE SPACE TO HAVE AT LEAST 1-HOUR FIRE SURROUND OR FIRE RATING AS REQUIRED <br /> BY LOCAL CODE (5/8" TYPE 'X' GYP. BD. ON METAL STUD FRAMING FROM FLOOR TO DECK AND SEALED TIGHT. 27'-102"SJB Brands, LLC <br /> VERIFY IN FIELD 17915 SKY PARK CIRCLE, SUITE J, <br /> 13'-92" 6'_7" 7°_6°° IRVINE, CA 92614 <br /> TEL: (949)475-0146 <br /> 13'-0" FAX:(949)475-0137 <br /> WALK IN BOX <br /> G.C. NOTES 1-0 11 <br /> � 6' 1 <br /> WALK 11 <br /> IN FREEZER ; WALK IN COOLER A-2.2 THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND <br /> -—-—-—-.-.-— ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN <br /> 1. G.C. TO FIELD VERIFY EXISTING SITE CONDITION PRIOR TO BIDDING THE PROJECT. `V THE PROPERTY OF GARY WANG & ASSOCIATES; AND NO PART <br /> THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN <br /> � o M� CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE <br /> 2. G.C. TO PATCH, REPAIR & REFURBISH THE EXISTING WALL, FLOOR & CEILING FINISH AT THE �El I i I SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND <br /> KITCHEN, WASHING & STORAGE AREA AS NEEDED OR OWNER'S INSTRUCTION. _ DEVELOPED WITHOUT THE WRITTEN CONSENT of GARY WANG & <br /> N 2" GAP / r `1 ASSOCIATES. VISUAL CONTACT WITH THESE DRAWINGS AND <br /> — SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF <br /> w - FID \ _ THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS <br /> O° 100 <br /> Z 107 108 2" GAP 105 I SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; <br /> I— — CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL <br /> HEALTH NOTES Y WALK-IN WALK-IN `D FFICE I 106 / I DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE <br /> FREEZER COOLER I MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS <br /> L ENDER AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAIL MUST <br /> \ STROOM I BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING <br /> 1. ALL EQUIPMENT SHALL MEET NATIONAL SANITATION FOUNDATION DESIGN AND INSTALLATION REQUIREMENTS OR IT'S WITH THE FABRICATION. <br /> EQUIVALENT. - I <br /> 3'-0" 14" � I ARCHITECT <br /> 2. LIGHT FIXTURES IN FOOD PREPARATION, OPEN FOOD STORAGE AND UTENSIL WASHING AREAS ARE TO BE "' U_ <br /> PROTECTED AGAINST BREAKAGE THROUGH THE USE OF PLASTIC SHIELDS, PLASTIC SLEEVES, SHATTER PROOF 1'-6" — — — <br /> BULBS AND/OR OTHER APPROVED DEVICES. <br /> 3. EXTERIOR DOORS SHALL BE SELF-CLOSING AND FIT TO A MAXIMUM 1/4" AT THE BASE AND SIDES. 8'-24„ 3'-1" 8'-7" Q0 17'-2"\ GARY WANG <br /> &ASSOCIATES, INC. <br /> 4. PROVIDE PERMANENTLY MOUNTED SINGLE SERVICE SOAP AND TOWEL DISPENSERS AT ALL HAND WASH BASINS. 2'-8» <br /> 5. SEAL ALL CRACKS AND CREVICES IN COUNTERS, CABINETS, AROUND METAL FLASHING, SINK BACKSPLASHES AND -- 1000 Corporate Center Dr., Suite 550 <br /> AROUND PIPES AND CONDUITS WITH A NON—HARDENING SILICONE SEALANT. 104 v L i Monterey Park, CA 91754 <br /> �� = 3 7—6 http://www.garywang.com <br /> 6. QUARRY TILE TO BE DAL TILE . BACKAREOOM 1" » TEL: (626)288 6898 FAX: (626)768-7101 <br /> T o 0 <br /> 7. ALL WALL & DRYWALL CEILING ARE TO BE PAINTED W/ SAME PAINT AS INDICATED ON THE FINISH SCHEDULE. o i "' 101 Ln <br /> 3' » SERVICE 7 -44 1'-3„ <br /> 8. ALL EXPOSED PIPES AND CONDUITS SHALL BE SPACED AT LEAST 1/2" FROM THE WALL. 4 AREA STAMP <br /> 9. ALL CABINETS SHALL BE LAMINATED INSIDE AND OUT. 2,`4 I <br /> I , _ <br /> +-� <br /> I <br /> I o <br /> I I _ C <br /> ��ED A� y1 <br /> WALL TYPES ~�' ' � r r <br /> H. <br /> N . C32569 <br /> —EXISTING WALL 12"X12" FLOOR SINK WITH � FD I 1 2 <br /> i 2'-6" RAW UICE ,1, <br /> DOME AND GRATE FLUSH 0 RE ...'04- - �� Q <br /> FA, <br /> FM FS WITH FINISHED FLOOR. > 103 BAR REA > <br /> PROVIDE MIN. 1 " AIR GAP PREP/ i ' �F <br /> El <br /> EXISTING STOREFRONT BETWEEN GRATE AND WASHING It» <br /> DRAIN PIPE. I 5'-21 �;�] <br /> AREA o <br /> NEW 3 5/8" STUD WALL 6" 0 <br /> ABOVE ADJACENT CEILING o <br /> —BRACED TO EXISTING FRAMING <br /> ABOVE. SEE DETAIL 1&2 ON <br /> SHEET A-3.0 -- PROJECT NAME/ADDRESS: <br /> t4 <br /> 3 <br /> NEW LOW WALL '-34" r, JUICE IT U P! <br /> RIPON TOWN SQUARE <br /> Ln <br /> ------- -- _ 1201 W. MAIN ST., <br /> WALK-IN BOX PANEL \ FSQ --- o-- <br /> N � T >=i�_I n 0 0 7 <br /> -LI-1 N RIPON, CA 95366 <br /> 3'-4" 5'-44" 2'- 4 2'-10" <br /> 8'-84„ 5-5„ 5,_14» <br /> REVISIONS: <br /> 30 MIN. , 100 T Q - <br /> i <br /> _ CUSTOMERS © _ <br /> N AREA <br /> ME <br /> CO z_ Q <br /> m dL b 8 – <br /> I � I <br /> N p ISSUE DATE: <br /> 1ST - <br /> 2ND - <br /> 3RD - <br /> / 4TH - <br /> 5TH <br /> 12'-6" 15 _42» 6TH <br /> 27'-104" <br /> VERIFY IN FIELD JOB NUMBER <br /> ARCH PROJECT#: 18-287 <br /> DRAWN BY CHECKED BY <br /> JR ADR <br /> SHEET CONTENT <br /> FLOOR PLAN AND <br /> DIMENSIONS <br /> N SHEET NO <br /> DIMENSIONED FLOOR PLAN A- 1 <br /> SCALE: 1/4"=1'-0" <br />