Laserfiche WebLink
I m <br /> z <br /> 0 <br /> 0 <br /> w <br /> 0 <br /> i <br /> EXISTING EMERGENCY EXIT SIGNS <br /> ❑3 AND LIGHTING TO REMAIN. <br /> I ' I <br /> ❑3 w <br /> I Q <br /> o OD > <br /> 0 I IW <br /> ` ENGINEER OF RECORD: <br /> O ❑ <br /> 2 <br /> 3 0 <br /> � I <br /> �'7n � 7 <br /> I u <br /> ❑3 F 1 3 0 *r <br /> F12S � aF cAOFo�`� <br /> I u � 12/2/19 <br /> ❑ a <br /> F13 1 y �t � <br /> D 0 � <br /> 5 � <br /> ❑3 <br /> Fl 2S INC <br /> ® d Fl 3 0 �/ / <br /> I <br /> W <br /> kin <br /> m 2 U <br /> ❑ Ld <br /> � a <br /> F13 QO Qo <br /> C m "i W U <br /> w oP <br /> 3 ELECTRICAL CONTRACTOR TO REUSE 4 ��' °� <br /> EXISTING FIXTURES IF POSSIBLE OR <br /> MATCH EXISTING KITCHEN FIXTURES AS o a <br /> SHOWN. REUSE EXISTING KITCHEN v ° <br /> NEW PANEL AP-4 AREA CIRCUITRY, CONTROLS AND I F13 <br /> EMERGENCY INVERTERS. <br /> o I o O Q N D p 0 <br /> ❑ I � J <br /> p h � <br /> F 13 <br /> ❑3 EXISTING EMERGENCY EXIT SIGNS <br /> I AND LIGHTING TO REMAIN. �/� <br /> I c a � 8 <br /> O : U 0. iJ U E <br /> N <br /> L oa- <br /> N p U O p O <br /> C C _ (� <br /> FNIa O D (n E U C <br /> p C U 0 x � 0 <br /> p O+� X <br /> (n U U N U <br /> J o iJ N <br /> iJ <br /> U N <br /> r (ll a U a <br /> U _D <br /> El 0U p O N (n <br /> Q � .N p c <br /> o _ L O U_ Q) <br /> se as o ° :5Q L L <br /> O p (n L 0 O-O <br /> O o <br /> 3 0: a O L <br /> D ® a >, O a cn <br /> w L (n p O <br /> �-' N N O !n (1).'_ <br /> U <br /> N p 7F N L (D <br /> a3 co— <br /> w <br /> 1 ELECTRICAL LIGHTING PLAN <br /> E2.0 <br /> 1 /4" _ V-0" <br /> GENERAL NOTES FOR DRAWING E2 . 0 : PROJECT DEMOLITION NOTES : EMERGENCY LIGHTING NOTES KEY NOTES <br /> EL1. EC SHALL INSTALL A LOCK ON CIRCUIT BREAKER HANDLE, FOR ALL <br /> LIGHTING INSTALLATION METHODS THE FOLLOWING PROVIDES A GENERAL SCOPE OF WORK FOR THE EMERGENCY LIGHTING CIRCUITS. EC SHALL VERIFY ALL REQUIREMENTS REUSE EXISTING CIRCUITRY AND CONTROLS FOR NEW r <br /> ELECTRICAL CONTRACTOR FOR THE DEMOLITION REQUIREMENTS OF THIS AND FINAL EMERGENCY LIGHTING LOCATIONS WITH LOCAL AUTHORITIES. F13/F12S LIGHT FIXTURES. Q <br /> 1 . ALL LIGHT FIXTURES SHALL BE 120 VOLT UNLESS NOTED OTHERWISE. SITE. THIS SECTION IS NOT ALL INCLUSIVE, AND THE CONTRACTOR SHALL INCLUDE ALL COSTS IN BASE BID. <br /> 1 . THE USE OF "MC" CABLE IN LENGTHS OF VISIT THE SITE AND COMPARE EXISTING CONDITIONS TO THE <br /> 2. LIGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVEL 6 FEET OR LESS (WHERE PERMITTED BY REQUIREMENTS DENOTED ON THE CONSTRUCTION DOCUMENTS TO EL2. IF NOT INSTALLED BY MANUFACTURER, EC SHALL BE RESPONSIBLE FOR2 ALL SOFFIT LOCATIONS, LIGHTING, & SUPPLY GRILLS SHALL <br /> OF ILLUMINATION. LAMP SPECIFICATIONS SHALL BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP SPECIFICATIONS SHALL BE LOCAL CODES) SHALL BE ALLOWED FOR DETERMINE THE EXACT EXTENT OF THE DEMOLITION WORK REQUIRED. E.C. THE COMPLETE INSTALLATION OF THE EMERGENCY INVERTER IN NIGHT � BE COORDINATED WITH DECOR COMPANY DRAWING PRIOR TO > <br /> APPROVED IN WRITING BY McDONALD'S CORPORATION. SHALL PROVIDE ALL DEMOLITION WORK REQUIRED IN ORDER TO ALLOW LIGHTING FIXTURES SHOWN ON THIS SHEET. INSTALLATION. n Q o <br /> WIRING TO THE LIGHTING FIXTURES. U) J <br /> FOR THE COMPLETE INSTALLATION AS DENOTED WITHIN THESE DRAWINGS. w z m <br /> 3. EC SHALL FIELD VERIFY THAT ALL LIGHT FIXTURES SHOWN ON THIS PLAN "ROMEX" OR "BX" SHALL NOT BE USED. EL3. LED FIXTURES DENOTED AS NIGHT LIGHTING OR SWITCHED EMERGENCY Q <br /> SHALL BE CONNECTED TO AN INVERTER. INVERTER SHALL BE CAPABLE 3 EXISTING LIGHTING TO REMAIN. U Z o w <br /> DO NOT OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. 2 EC SHALL VERIFY THAT NOT MORE THAN <br /> OF ILLUMINATING FIXTURE FOR 1.5 HOURS TO COMPLY WITH NEC w _D � <br /> IFA DISCREPANCY IS FOUND, THE EC SHALL IMMEDIATELY NOTIFY THE 3% VOLTAGE DROP EXISTS FROM THE U 0 ~ V ~ <br /> SECTION 700 AND UL924. D cn <br /> GC BEFORE THE INSTALLATION OF SUCH FIXTURE(S). LIGHTING PANEL TO ANY EXTERIOR GENERAL PROVIDE LIGHTING INVERTER FOR USE WITH FIXTURES SHOWN Q o <br /> LIGHTING FIXTURE OR SIGNAGE BALLAST. EL4. EMERGENCY BATTERY LIGHTING WALL PACKS IN PLAYPLACE SHALL BE SHADED OR SLASHED. MODEL #LG125T SHOULD BE USED m Fy = o 0 <br /> 4. ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LOCAL CODES FROM SECURITY LIGHTING. D1 . THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SALVAGE LOCATED SO AS TO PROVIDE FOR MAXIMUM ILLUMINATION OF AREA. FOR Fl 2S, F12SA & FI2C WITH NOT MORE THAN EIGHT m z w o <br /> - FOR RED LETTERS USE #PRB (UNIVERSAL), REQUIREMENTS FOR ALL EQUIPMENT REMOVED AS PART OF THE EC SHALL VERIFY EXACT PLACEMENT IN THE FIELD WITH McDONALD'S DOWNLIGHTS CONNECTED TO EACH INVERTER. IF DECOR USES - O U~- <br /> - FOR GREEN LETTERS USE #PGB (UNIVERSAL), OR DEMOLITION WORK WITH THE CONSTRUCTION PROJECT MANAGER. ALL ACM. (IF APPLICABLE) ALTERNATE FIXTURES, COORDINATE INVERTER TO BE USED Q Z Q w <br /> IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE: LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE & EQUIPMENT TO BE SALVAGED AND/OR REUSED SHALL BE PROTECTED WITH LIGHTING SUPPLIER. E.C. SHALL VERIFY THE QUANTITY Z 0 z <br /> DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. FROM DAMAGE UNTIL REINSTALLED OR THE TIME PERIOD WHEN IT IS EL5. EMERGENCY LIGHTING HAS BEEN DESIGNED PER NFPA 101 TO MAINTAIN 1 a w o <br /> FC IN PATH OF EGRESS. IF FIELD CONDITIONS REQUIRE ANY OF FIXTURES THAT CAN BE CONNECTED WITHOUT EXCEEDING u7 <br /> TURNED OVER TO THE OWNER AND/OR THE PROJECT MANAGER. OPERATING CAPACITY OF UNIT AND PROVIDE ADDITIONAL o <br /> 5. ALL NON EMERGENCY LIGHTING IS TO BE ROUTED THROUGH THE BUILDING ENERGY MANAGEMENT SYSTEM FOR COMPLETE BUILDING CHANGES TO LIGHTING DESIGN, EMERGENCY LIGHTING, SHALL BE J O X U O x w <br /> LIGHTING AUTO SHUT-OFF INSTALLED TO MEET THE ABOVE REQUIREMENTS. CIRCUITS AND INVERTERS AS REQUIRED. (TYPICAL) N W o U w o <br /> D2. SEE THE GENERAL ELECTRICAL SPECIFICATIONS AND NOTES ON SHEET cn o <br /> E1 .0 FOR ADDITIONAL GENERAL REQUIREMENTS. <br /> D3. THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ALL 5 DRAFT STOP ABOVE CEILING. E.C. TO ENSURE INTEGRITY OF <br /> FIRE RATED WALLS WHERE ELECTRICAL EQUIPMENT z <br /> EXISTING LIGHT FIXTURES IN THE AREAS ASSOCIATED WITH THE PENETRATES WALLS. SEAL PER SPECIFICATIONS FOR FIRE <br /> REMODEL TO ALLOW FOR THE NEW LIGHTING FIXTURE INSTALLATION AS ow E29 0 <br /> DENOTED ON THE PLANS AND DECOR DRAWINGS. COORDINATE ALL STOPPING. U) LIGHTING PLAN <br /> WORK WITH OTHER TRADES AND WITH THE PROJECT MANAGER. <br />