My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
5654
>
1600 - Food Program
>
PR0522630
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2022 3:00:08 PM
Creation date
8/18/2020 8:59:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0522630
PE
1625
FACILITY_ID
FA0015421
FACILITY_NAME
SMITTYS WINGS & THINGS
STREET_NUMBER
5654
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10815012
CURRENT_STATUS
01
SITE_LOCATION
5654 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br /> DIVISION 16 - GENERAL ELECTRICAL.. smitty's <br /> STORAGE <br /> GENERAL Wings <br /> 1. INSTALL ALL ELECTRICAL IN THIS WORK PER LATEST NEC AND CITY OF STOCKTON BUILDING DEPT. 5654 N. PERSHING AVENUE <br /> REQUIREMENTS. FLEXIBLE CONDUIT MAY BE USED BUT MUST CARRY GROUND WIRE TO BOX. <br /> SWITCH LIGHTING AS INDICATED ON DRAWINGS. ALL CIRCUITS SHALL BE MARKED TO INDICATE STOCKTON, CA 95207 <br /> M R /R W R 'R WALK IN FREEZER AREAS SERVED. PROVIDE ADDITIONAL CIRCUITS AS REQUIRED BY OTHER TRADES. GENERAL <br /> ELECTRICAL MAYBE RUN IN FLEXIBLE METAL CONDUIT, MC OR EMT. SETSCREW FITTINGS ON EMT. <br /> MC CABLE TO USED IN CONCEALED WALL OR CEILING. INSTALL ALL FIXTURES PER MFG REQ. USE <br /> ONLY APPROVED AND LISTED EQUIPMENT. <br /> 2. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THWN/THHN. USE CONNECTORS APPROVED <br /> FOR RELATED WIRE SIZE_ THE USE OF STRANDED OR SOLID APPROVED. USE STRANDED FOR SIZES <br /> A B #8 OR LARGER <br /> KITCHEN AREA 3 ALL WORK SHALL CONFORM TO THE CEC 2016 EDITION AND TO THE APPLICABLE REQUIREMENTS <br /> > IT OF LOCAL, STATE, AND FEDERAL CODE(S) AND/OR AGENCIES HAVING JURISDICTION; AND SHALL <br /> TAKE PRECEDENCE OVER WORK SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE <br /> Vol ATTENTIONOF THE DESIGNER PRIOR TO THE INSTALLATION OF WORK. <br /> ANSUL <br /> 4. ELECTRICAL CONTRACTOR SHALL VERIFY DIAGRAMMATIC LAYOUT OF ELECTRICAL WORK WITH <br /> OWNER PRIOR TO INSTALLATION. <br /> 5. SEE ELECTRICAL SYMBOLS, VERIFY ALL SYMBOLS AND CONDITIONS AS REQUIRED PRIOR TO <br /> ANSUL-2 U-I INSTALLATION. <br /> IY <br /> Ld <br /> LL <br /> JOB CONDITIONS <br /> KEF-1 6. ELECTRICAL DRAWINGS: THE ELECTRICAL DRAWINGS, AS CONTAINED, ARE ESSENTIALLY <br /> ANSUL-1 DIAGRAMMATIC AND ALTHOUGH THE SIZE AND LOCATION OF EQUIPMENT ARE SHOWN TO SCALE <br /> WHEREVER POSSIBLE CONTRACTOR SHALL MAKE USE OF ALL DATA AND VERIFY THIS INFORMATION <br /> AT THE BUILDING SITE. THE DATES INDICATED ON THE DRAWINGS AND IN THE JOB CONDITIONS <br /> AND DECISIONS OF THE DESIGNER WILL GOVERN EXACT LOCATIONS, DISTANCES, LEVELS, AND <br /> z <br /> OTHER CONDITIONS. <br /> MUA-1 <br /> 7. OPERATION : <br /> THE SYSTEM SHALL BE COMPLETE AND FULLY FUNCTIONING TO THE SATISFACTION OF THE <br /> DESIGNER AND THE OWNER. INSTALL ALL CIRCUITS, J-8OXFS, WIRING DISCONNECTS AND ANY <br /> DINING AREA OTHER EQUIPMENT NEEDED TO PROVIDE ELECTRICAL SERVICE FOR SIGNAGE. <br /> 8. DRAWINGS: <br /> THE LAYOUT OF LIGHT FIXTURES ARE TO BE DIVIDED IN THE ROOM AS SHOWN ON THE PLANS_ <br /> ANY Questions ABOUT LAYOUT SHOULD BE DIRECTED TO THE ENGINEER. UPON COMPLETION OF <br /> THE INSTALLATION, FURNISH A SET OF 'RECORD' (AS-BUILT) DRAWINGS TO THE DESIGNER <br /> CLEARLY MARKED WITH THE CHANGES AUTHORIZED DURING CONSTRUCTION, CUTTING NOTCHING <br /> DRILLING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK HEREIN INCLUDING CUTTING, <br /> BORING, NOTCHING, FURRING AND DRILLING AS NECESSARY TO COMPLETE THIS PROJECT. "NOTE: <br /> NO CUTTING, BORING, NOTCHING, FURRING AND DRILLING OF TRUSS OR OTHER STRUCTURAL <br /> MEMBERS WILL BE ALLOWED. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO ALLOW <br /> FOR GROUP RUNS AND ELIMINATE ANY OVERLAPPING OR OBSTRUCTION. <br /> 9. WORKING CLEARANCES <br /> WORKING CLEARANCE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT INCLUDING DISCONNECTS <br /> - - - - _ - WILL BE MAINTAINED AS PER CEC 2016 ARTICLE 110.26 <br /> mem .i r- �ustria] <br /> NORTH 1 o COMPLETION OF WORK AND TEST Davi4 L. Ja: -a: . President <br /> POWER PLAN DW �� � CA #473893 <br /> _ _ _ THE ENTIRE ELECTRICAL SYSTEM SHALL BE FREE FROM ANY SHORT CIRCUITS, AND IMPROPER ea;ra Da PWaa, s..>ar.e s <br /> 1/4" = 1'--0„ GROUNDS. DEMONSTRATE WITH THE OWNER AND DESIGNER THAT THE ENTIRE INSTALLATION IS <br /> Stockton, F 94739 <br /> (209] 4773-2688 Fsx 473-2871 <br /> COMPLETE AND IN PROPER OPERATING CONDITION. Email: David6DLJE1ectr1c.eom <br /> These drawings and specifications are the property and <br /> copyright of DLI Electric and shall not be used or duplicated in <br /> part or in whole on any other work except by agreement with <br /> 138lectric. . <br /> A B <br /> J O B NOTES ROOM VOLTS 208Y/120V 3P 4W AIC 22,000 ROOM VOLTS 208Y/120V 3P 4W AIC 22.ODO <br /> MOUNTING FLUSH BUS AMPS 200 MAIN BKR MLO MOUNTING FLUSH BUS AMPS 200 MAIN BKR MLO t <br /> FED FROM UTILITY NEUTRAL 100% LUGS STANDARD FED FROM UTILITY NEUTRAL 100% LUGS STANDARD H VAC <br /> NOTE PANEL AND FEEDERS ARE EXISTING NOTE PANEL AND FEEDERS ARE EXISTING <br /> 1. ELECTRICAL PANEL & RELATED FEEDERS ARE EXISTING CKT CKT LOAD CKT CKT LOAD CKT CKT LOAD CKT CKT LOAD <br /> BKR KVA CIRCUIT DESCRIPTION # BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION 1# BKR KVA CIRCUIT DESCRIPTION POWER <br /> 2_ INSTALL ELECTRICAL POWER TO HVAC UNITS KEF-1 & MUA-1 1 20/1 1.2 LIGHTS a 2 20/1 1.5 TRACK LIGHTS 1 20/2 1.6 DOUGH ROLLER a 2 15/2 2.08 ICE MACHINE <br /> 3. CONNECT UNITS TO EXISTING ANSUL SYSTEM WITH AUTOMATIC SEQUENCING OF UNITS DURING 3 20/1 0.75 WALL SCONCES b 4 20/1 1.5 TRACK LIGHTS 3 1 b 4 1 <br /> ACTIVATION OF ANSUL SYSTEM 5 20/1 1.1 SOFFET LIGHTS c 6 20/1 1.5 TRACK LIGHTS 5 20/3 1.4 EXHAUST FAN c 6 20/1 1.5 MAKE UP AIR PLA N <br /> 7 20/'1 0.75 TV ❑ 8 20/1 0.72 RECEPTACLES 7 1 a 8 15/2 1.25 WAWN COMPRESSOR <br /> 4. INSTALL DISCONNECTS @ EACH UNIT 9 20/1 0.36 VIDEO GAMES b 10 20/1 0.72 RECEPTACLES 9 1 b 10 1 <br /> 11 20/1 0.36 VIDEO GAMES c 12 20/1 0.72 RECEPTACLES 11 20/1 0.18 RECEPT GR ROOF c 12 20/1 1.2 AIR DOOR <br /> 5. CONFIRM GF1 PROTECTED SERVICE OUTLET IS WITHIN 25 OF UNITS 13 20/1 0.36 VIDEO GAMES a 14 20/1 1.3 SIGNAGE 13 20/1 1.6 LIGHTS a 14 20/1 0.18 RECEPTACLE NEXT TO DOUGH <br /> 6. NO OTHER ELECTRICAL WORK IS BEING DONE WITHIN THIS SPACE 15 20/1 0.36 VIDEO GAMES b 16 20/1 1.5 SHOW WINDOWS 15 20/1 0 SPACE b 16 20/1 1.5 WALKIN COOLER <br /> 17 20/1 0.85 RESTROOMS c 18 20/1 1.1 SALAD 17 20/1 0 SPACE c 18 20/1 1.25 BEER DISPENSER <br /> 7- UPDATE PANEL SCHEDULES 19 20/1 0 SPACE a 20 20/1 1.1 SODA 19 20/1 0 SPACE a 20 20/1 0 SPACE SUBMITTAL 02/27/19 <br /> 21 20/1 0 SPACE b 22 20/1 0.36 PREP TABLE 21 20/1 ❑ SPACE b 22 20/1 0 SPACE <br /> 23 20/1 0 SPACE c 24 20/1 1.3 AIR DOOR 23 20/1 ❑ SPACE c 24 20/1 0 SPACE <br /> 25 20/1 0 SPACE a 26 20/1 1.5 DISHWASHER 25 20/1 0 SPACE a 26 50/3 14.4 ROBO-COUP <br /> 27 20/1 0 SPACE b 28 20/1 1.5 REFER FRONT COUNTER 27 20/1 ❑ SPACE b 28 1 <br /> 29 20/1 0 SPACE c 30 20/1 1.5 REFER FRONT COUNTER 29 20/1 0 SPACE c 30 1 <br /> 31 20/1 0 SPACE a 32 20/1 1.2 POS FRONT COUNTER 31 20/1 D SPACE a 32 40/3 10.8 A/C UNIT <br /> 33 20/1 0 SPACE b 34 20/1 0.6 POS FRONT COUNTER 33 20/1 0 SPACE b 34 1 <br /> HVAC S CLI�'D UL ' 35 20/1 0 SPACE c 35 20/1 1.6 FREEZER 35 20/1 0.18 RECEPTACLE c 36 1 <br /> 37 20/1 0 SPACE a 38 20/1 0.6 POS KITCHEN 37 40/3 10.8 A/C UNIT a 38 30/2 3.4 A/C UNIT <br /> 39 30/2 3.1 PANEL ANSUL b 40 20/1 0 SPACE 39 1 b40 1 <br /> CALLOUT SYMBOL VOLTS AMPS HVA IIP CIRCUIT <br /> 41 1 c 42 20/1 0 SPACE 41 1 c 42 20/1 D SPARE <br /> K EF--1 120V 1P 2W 9.8 1.18 1/2 HP CONN CALC CONN CALC CONN CALC CONN CALC <br /> KVA KVA KVA KVA KVA KVA KVA KVA <br /> MUA-1 120V 1P 2W 16 1.92 1 HI' LIGHTING 9.35 11.7 (125%) RECEPTACLES 6.57 6.57 (50%]10) LIGHTING 1.6 2 (125%) KITCHEN 208 2.08 (100X) <br /> LARGEST KITCHEN LARGEST EQUIPMENT <br /> MOTOR 1'92 0.4$ (25%} EQUIPMENT fi.1 4.88 (80%) MOTOR 14.4 3.fi (25%} CONTINUOUS 2.75 3.44 (125%) <br /> MOTORS 4.4 4.4 (100%) CONTINUOUS 1.7 2.13 (125%) MOTORS 21.4 21.4 (100%) HEATING 25 25 (100%) <br /> NONCONTINUOUS 2.9 2.9 (100%) RECEPTACLES 0.54 0.54 (50%]10) COOLING 25 0 (0%) <br /> TOTAL LOAD 33 TOTAL LOAD 58 <br /> BALANCED 3-PHASE BALANCED 3-PHASEELO <br /> AMPS 91.7 AMPS 1fi1 <br /> PHASE A 9&9% PHASE A 104% <br /> PHASE B 104% PHASE 9 102% <br /> PHASE C 97.1% PHASE C 93.8% <br /> F <br />