Laserfiche WebLink
(E) ROOT= BOTOM OF TRUSS CHORD. (E) ROOFBOTTOM OF TRUSS CHORD. <br /> DESIGNERS & ARCHITECTS <br /> Architect: <br /> LDA Partners, LLP <br /> Designers &Architects <br /> 3"x1/4" DIAMETER CLOSED (2) #5 x 1/2" SELF-TAPPING SCREWS 222 Central Court <br /> EYE SCREW WITH 1 1/2" MIN. Stockton, CA 95204 <br /> EMBEDMENT 31W X 4"L X 12 GA. STEEL STRAP <br /> 209.943.0405 <br /> 3 TIGHT TURNS W/IN 1 1/2" <br /> 3 TIGHT TURNS W/IN 1 1/2" www.ldapartners.com <br /> #12 HANGER WIRE #12 BRACING WIRE Svvo R O LAS,o,�� <br /> o <br /> C32705 <br /> 5 T-BAR HANGER WIRE T-BAR !BPLAY BRACE October 2019 <br /> D.03 3" = 1'-0" D.03 3" = 1'-0" 9TF OF CAS-���� <br /> 12 GA. HANGER UNDERSIDE OF NO. 12 GA. VERTICAL <br /> SUPPORT WIRE5 FLOOR OR HANGER WIRE W/IN <br /> TYP. CEILING ABOVE TUBE - LEVEL CEILING <br /> 5/32" DIA. HOLE W/ GRID PRIOR TO <br /> 1/8" DIA. BOLT B SETTING TUBE <br /> LOCKING NUT MEMBER "A" - REFER <br /> MEMBER "B" - REFERTO COMPRESSION Client: <br /> TO COMPRESSION POST SCHEDULE Sammy Orlando <br /> POST SCHEDULE `t BELOW FOR SIZE <br /> MAIN/CRO55 RUNNER BELOW FOR SIZE I <br /> LI) SLOT END OF EMT 18754 E Highway 26 <br /> ** NOTE ** TO FIT OVER <br /> EXTEND TUBE TIGHT TO Linden CA 95236 <br /> CEILING 4 STRUCTURE CEILING RUNNER 209.887.1 100 <br /> ABOVE PRIOR TO MAIN RUNNER <br /> SECURING OVERLAPPING <br /> TUBES. PROVIDE A MIN. 4" CROSS RUNNER <br /> 1/4" LAP BETWEEN TUBES IN <br /> FULLY EXTENDED <br /> POSITION. <br /> HUNTER DOUGLAS GOMPRE55I0N P05T SCHEDULE <br /> TECHSTYLE WHITE MAXIMUM LENGTH MEMBER "A" MEMBER "B" Project: <br /> SWING DOWN Orlando's Market Bar & Grill <br /> ACOUSTIC PANELS 6'-6" 1" DIA. EMT 1 1/4" DIA. EMT <br /> LIGHT FIXTURE, 8'-6" 1 1/4" DIA. EMT 1 1/2" DIA. EMT 18754 E Highway 26 <br /> REFER TO ELEC DWG5 9'-10" 1 1/2" DIA. EMT 1 3/4" DIA. EMT <br /> Linden CA 95236 <br /> 15'-0" 2" DIA. EMT 2 1/4" DIA. EMT <br /> 6 LINEAR LIGHT FIXTURE r2COMPRE55ION P05T <br /> REFER TO DETAIL 2 /AD.03 <br /> FOR COMPRESSION <br /> 12 GA. HANGER WALL ANGLE - TYP. POST <br /> ALUMINUM SUPPORT WIRE5 <br /> EDGE VERTICAL SUSPENSION <br /> PROFILE WIRE - TYP. - INSTALL <br /> HUNTER LATERAL SPLAY WIRE <br /> UGLAS BRACING AT CEILING ATTACHED WALL <br /> DO <br /> "TTDO TRIM AREAS GREATER THAN 144 <br /> TYP @ ALL S.F. <br /> EDGES <br /> 2" OVERSIZED TRIM RING - <br /> MAIN/CRO55 RUNNER TYP. @ FIRE SPRINKLER <br /> �vv cO PENETRATIONS- COLOR TO — TYP. <br /> MATCH GLC. PANEL <br /> < <br /> MAIN SUSPENSION o <br /> RUNNER - TYP. Ca v <br /> CR055-TEE - TYP. v <br /> z <br /> 3/4" 1/4" NOTE: <br /> SUSPENSION SYSTEM <br /> COMPONENTS SHALL BE UNATTACHED WALL <br /> HUNTER DOUGLAS "HEAVY DUTY TYPE" TO Project No.: 715-02-18 <br /> "TEGHSTYLE WITHSTAND SEISMIC 2'-O" <br /> GRAPHICS" LOADS IN ACCORDANCE TYP Drawn By: VR <br /> SWING DOWN WITH GBG SECTION 1613 Checked By: PR <br /> ACOUSTIC PANELS AND ASCE -f-10 FOR <br /> CATEGORY D. <br /> 5U5PENDED CEILING EDGE DETAIL 3 TYP. 5U5i' ACOUST. i'NL. CEILING No. Description Date By <br /> D.03 3" = 1'-0" D.03 1/4" = 1'-0" <br /> VERTICAL SUPPORT: <br /> METAL SUSPENSION SYSTEM FOR 12 GAUGE WIRE5 4' ON CENTER WITHIN 5" OF EACH WALL. <br /> ACOUSTICAL TILE AND FOR LAY-IN FOR COMPRESSION POST HANGER WIRE5 TO BE WITHIN 1:6 OF PLUMB UNLE55 COUNTER SLOPING WIRE5 <br /> PANEL GEILIN65 ATTACHMENT <br /> M MENNTT TTO O ROOF ARE PROVIDED. <br /> FRAMING, SEE STRUGT. <br /> DWG5. LATERAL BRACING: <br /> GRO55 12 GAUGE WIRE, 4 WIRE5 SECURED WITHIN 2" OF THE CROSS RUNNER <br /> RUNNERS @2'-0" COMPRESSION INTERSECTION AND SPLAYED 90° FROM EACH OTHER AT AN ANGLE NOT <br /> POST REFER TO EXCEEDING 45° FROM THE PLANE OF THE CEILING. A STRUT FASTENED TO THE <br /> O.G. DTL. 2/AD.03 MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURE <br /> N <br /> E MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THESE 4 WIRE BRACING <br /> 450 450 POINTS TO BE WITHIN 6OF EACH WALL AND 12' O.G. IN EACH DIRECTION. FOR <br /> W 5 TILE GEILIN65, ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED <br /> MAIN TOGETHER TO PREVENT THEIR SPREADING. PERMIT SUBMITTAL <br /> RUNNERS @ <br /> 4'-0" O.G. LIGHTING FIXTURES ("Intermediate" systems) 8/15/2018 <br /> ALL LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED <br /> CEILING SYSTEM. NO. 12 GAUGE HANGER5 SHALL BE ATTACHED TO THE GRID <br /> 12 GA. SUPPORT MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE. IN ADDITION TO <br /> WIRE5 - TYP. 450 THE ABOVE, PROVIDE TWO NO. 12 GAUGE HAN6ER5 CONNECTED FROM THE <br /> REFER TO 1/AD.03 FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRE5 MAY BE SLACK. DETAILS <br /> 4.50 REFER TO DETAIL 5/AD.01 <br /> MECHANICAL SERVICES: <br /> CEILING MOUNTED AIR TERMINALS WIGHING LE55 THAN 20 POUNDS SHALL BE <br /> POSITIVELY ATTACHED TO THE CEILING RUNNERS. TERMINALS WEIGHING <br /> NOTE: VERT. STRUT @ SPLAY MORE THAN 20 POUNDS SHALL BE INSTALLED A5 PER LIGHT FIXTURE. <br /> WIRE BRACING 12'-0" O.G. W/ FIRST <br /> POINT WITHIN 6 FT. FROM EA. WALL REFERENCE: <br /> M GBG 803.9.1.1, GBG 1613A, ASCE -7-10 CHAPTER 13, ASTM 635, ASTM 636, ICG E5 <br /> REPORT, AND MANUFACTURER'S SPECIFICATIONS. <br /> (D5U5PENPEP CEILING T-BAR GRIDAD * 03 <br />