Laserfiche WebLink
SAN JOANN a <br /> Environmental Health Department <br /> COUNTY <br /> Linda Turkatte , REHS , Director <br /> Greotness grows here . Kasey Foley , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> May 9 , 2018 <br /> MARTY WEITHMAN <br /> SERVICE STATION SYSTEMS INC <br /> 680 QUINN AVE <br /> SAN JOSE , CA 95112 <br /> Re : TIWANA GAS & FOOD SR0078906 <br /> 1210 E HAMMER LN <br /> STOCKTON , CA 95210 <br /> The amended San Joaquin County Environmental Health Department ( EHD ) has completed review of <br /> the application for a permit to install new primary 91 product Flexing " Fireflex" flexible connectors and <br /> Bravo flex boots ( B -2000 series ) on the 91 primary product line at dispensers 1 /2 and 5/6 on the <br /> underground storage tank ( UST) system at the above noted address . The permit has been approved <br /> with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Elianna Florido at (209 ) 468 - 0343 to arrange the following appointments ( a 48- hour <br /> notice is required for inspection appointments ) . Please be aware that inspection for emergency <br /> work must be scheduled within five days of permit approval . <br /> Witness soil sampling from under the removed primary piping based on field <br /> observations and as outlined in the sampling protocol . Analytical results to be provided <br /> to Environmental Health Department , The San Joaquin County Sampling Protocol For 1 <br /> Routine Piping/Dispenser Removal /Replacement shall be followed . <br /> • Primary piping soap test : One hour pneumatic pressure test for the 91 -octane piping , at <br /> 110 % of operating pressure , or 40 psi , whichever is greater. <br /> • Secondary piping soap test : One hour pressure test of the 91 -octane piping , per <br /> manufacturer' s guidelines . If there are no manufacture ' s guidelines , test shall be <br /> performed using an applicable method specified in an industry code or engineering <br /> standard . <br /> • Secondary piping test for all product piping in the vicinity of under dispenser <br /> containments ( UDCs ) 1 /2 and 5/6 (where excavation took place) : One hour pressure <br /> test for all piping , per manufacturer' s guidelines . If there are no manufacture ' s <br /> guidelines , test shall be performed using an applicable method specified in an industry <br /> code or engineering standard . <br /> • 24 - hour hydrostatic test (or equivalent) on UDC sumps 1 /2 and 5/6 . <br /> • Primary piping test : Witness tightness test performed by SWRCB licensed tank tester or <br /> receive passing 0 . 1 gallon per hour test results from the PLLD ( if installed ) . A visual <br /> inspection is required for PLLD tested lines . <br /> 1868 E . Hazelton Avenue I Stockton , California 952051 T 209 468 - 34201 F 209 464 -0138 1 www . sjcehd . com <br />