UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM ( Page -I of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ❑x 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 3/ 13/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> 7 - Eleven #35355 <br /> Business Site Address City ZIP Code <br /> 3202 W Hammer Ln Stockton 95209 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification .) Phone # <br /> Anthony Reyes 1 ( 916 ) 373 - 1166 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 617238 8293772 9/ 16/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> OPW UST Phase 1 EVR Tech# 103920 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines (Specify) : <br /> Used : OPW Install & Maintenance Guidelines <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> ❑ Engineered Method (Specify) : <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) 87 Gasoline 91 Gasoline Diesel <br /> What is the tank inside diameter? (Inches) 117 . 75 117 . 75 117 . 75 <br /> Is the fill piping secondarily contained ? 0 Yes ❑ No 0 Yes ❑ No ❑x Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained ? ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow 0 Shuts Off Flow ❑ Shuts Off Flow <br /> when activated ? <br /> (Check all that apply.) ❑ Restricts Flow ❑ Restricts Flow El Restricts Flow ❑ Restricts Flow <br /> ❑ A/V Alarm ❑ A/V Alarm ❑ A/V Alarm ❑ A/V Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 103 . 375 103 . 375 104 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates ? 94 % 94 % 94 % <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes Z Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) It ❑ No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail " must be explained in this section. Any additional comments may also be provided here . <br /> Replaced all three droptubes with new. Inspector onsite to witness installation . <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23 , <br /> Division 3, Chapter 16 , Section 2637 . 2 and all the information contained herein is accurate . <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = Califomia Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AIV = Audible and Visual <br />