SAN <br /> J D �� I Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CANEPAS CAR WASH STORE 642 N HUNTER ST, STOCKTON June 27, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 HSC 25284(a)(3)(A)/(B)No written agreement between tank owner and tank operator to monitor the tank system. <br /> The annual operating permit is not issued to the current operator and there is no written agreement between the <br /> person who was issued the permit and the operator to monitor the UST system. If a permit is issued to a person <br /> other than the operator of the tank,that person shall enter into a written agreement with the operator of the tank to <br /> monitor the UST system. Immediately submit a copy of this written agreement to the EHD. Alternatively, log into <br /> CERS, upload the written agreement, and submit for review by the EHD. <br /> This is a minor violation. <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Financial responsibility documents have not been submitted to the EHD. The financial responsibility documents on <br /> CERS are dated 4/12/18. Current financial responsibility documents are required to be submitted annually. <br /> Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, and <br /> upload the required documents. <br /> This is a minor violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> 1) UST Facility Operating Permit is not current in CERS.The California Department of Tax and Fee Administration <br /> (CDTFA, previously BOE)number listed on CERS is not associated with the new owner.Any change of information <br /> must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the required <br /> information, and submit for review by the EHD. <br /> 2) UST Tank Information forms for the 87 and diesel product tanks are not current in CERS. Under tank <br /> configuration for the 87 and diesel product tanks,tanks are incorrectly stated to have compartments. Both of these <br /> tanks are standalone tanks.Any change of information must be updated in CERS within 30 days of the changes. <br /> Immediately log into CERS, update the required information, and submit for review by the EHD. <br /> This is a minor violation. <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> On the monitoring plans for all tanks, under dispenser containment(UDC)monitoring,the following sections were <br /> incorrectly marked: <br /> -"Detection of Leak into UDC Triggers Audible and Visual Alarms" <br /> -"UDC Leak Alarm Triggers Automatic Pump Shutdown" <br /> -"Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown" <br /> -"UDC Monitoring Stops Flow of Product at Dispenser" <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> FA0000799 PR0231148 SCO01 06/27/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />