rn <br /> C <br /> C 0] <br /> — � C <br /> La <br /> O L6 41 <br /> N D CO m <br /> CN tA <br /> �2 r ❑ C <br /> ❑ LO v <br /> 6ENERAL NOTES KEYED NOTES <br /> V o <br /> A. HVAG ROOF GURB5 SLOPED TO MATCH ROOF PITCH SHALL BE PROVIDED BY 8 TENANT'S CONTRACTOR TO PROVIDE NEW INLINE EXHAUST FAN A5 SHOWN. ROUTE S"DIA *�� o ; a � a� <br /> CONTRACTOR AND ARE NOT PART OF THE NATIONAL ACCOUNT PROVISIONS. DUCT UP THRU ROOF TO 6005ENEGK. MAINTAIN 10'-0" FROM ALL OUTDOOR AIR I <br /> INTAKES. Q " � 4 Ed <br /> B. CONTRACTOR SHALL IDENTIFY ALL HVAC EQUIPMENT WITH STORE NAME AND UNIT E `r' <br /> 2 EXI5TIN6 HVAC UNIT, CURB AND ROOF OPENIN6 TO REMAIN. CONTRACTOR SHALL _ _ _ _ _ _ _ _ _ _ m ; Z <br /> NUMBER U51N6 PERMANENT, WEATHER PROOF 2 HIGH DIE-GUT LETTERS. SERVICE HVAC COMPONENTS AND PROVIDE AND INSTALL NEW ACCESSORIES AND A c CO C z <br /> CONTROLS A5 INDICATED ON PLANS, 5GHEDULE AND NOTES. Q ' 2S ° W d <br /> G. PROVIDE PROPER CONDENSATE TRAP AND TERMINATE A5 REQUIRED BY LOCAL � a � E <br /> CODE. COVER OPEN END OF RETURN DUCT WITH I" MESH HARDWARE CLOTH IN A REMOVABLE <br /> METAL FRAME. SEE DETAIL SHEET MP2. <br /> D. ANY PENETRATION THROUGH THE ROOF SHALL BE COORDINATED WITH THE CONNECT SUPPLY AND RETURN AIR DUCTS TO DROPS FROM UNIT WITH TRAN51TION <br /> LANDLORD'S FIELD REPRESENTATIVE AND SHALL BE DONE BY A LANDLORD <br /> APPROVED ROOFIN6 CONTRACTOR IN ORDER TO MAINTAIN THE ROOFING FITTINGS. DO NOT "HARD TAP" DROPS FROM UNIT. <br /> WARRANTEE. ALL VENTS SHALL EXTEND A MINIMUM OF 12 INCHES ABOVE ROOF AND 8 <br /> SHALL BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKE. ADJUST DIFFUSER FOR FULL VERTICAL DISCHARGE INTO OFFICE BELOW. <br /> 8 TENANTS CONTRACTOR SHALL INSTALL TENANTS VENDOR PROVIDED G02 5EN50R ON <br /> E. ALL DUCT SIZES 5HOWN ARE CLEAR INSIDE AIR FLOW DIMENSIONS. COLUMN AT 6-0" A.F.F. THI5 5EN50R SHALL CONTROL RTU-I, 2, 3. SEE EM5 SYSTEM B — <br /> SHEETS FOR MORE INFORMATION. <br /> F. DO NOT PROVIDE AIR EXTRACTORS OR SPLITTER DAMPERS WHIGH PROTRUDE INTO Q <br /> REGTAN6ULAR TRUNK DUCTS WERE USED). PROVIDE ROUND SPIN-IN FITTINC75 FOR CONTRACTOR SHALL LOCATE BOTTOM OF STOCK ROOM DUCTWORK 12'-O" MIN. ABOVE N <br /> STOCK ROOM FLOOR ABOVE L16HT5. ANY DEVIATION TO TH15 DIMEN51ON DUE TO cl-lb/10 � <br /> ROUND BRANCH DUCTS. INTERFERENCE WITH ANY BUILDIN6 065TRUGTION5 SUCH AS STRUCTURE, OVERHEAD Q <br /> 6. ROUND BRANCH DUCTS WHERE INDICATED ARE SAME 51ZE A5 ATTACHED DIFFUSER DOORS, ETC. SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO G-18 10 G-I8 10 G-I8 10 Q <br /> NECK SIZE. FABRIGATIN6 THE DUGTWORK. 420 420 420 N <br /> E-6 E-6 <br /> TRANSFER AIR OPENIN6 IN WALL A5 H16H A5 POSSIBLE. 14"DIA 16"DIA 14"DIA 100 6/ 6/6100 <br /> H. DO NOT SUSPEND ANY ITEMS FROM DECK OR SLAB ABOVE. ALL ITEMS SHALL <br /> 8�� <br /> SUSPENDED FROM STRUCTURE UNLE55 OTHERWI5E NOTED. PROVIDE MISCELLANEOUS <br /> STEEL A5 REQUIRED. Q = <br /> 7 Q - co <br /> I. WHERE GEILIN6 SPACE 15 NOT SUFFICIENT TO PERMIT TOP CONNECTION TO GEILIN6 O 814/12 N EF o <br /> DIFFUSER WITH PROPER BEND RADIUS FOR FLEXIBLE DUCT, CONTRACTOR SHALL A-12 8 cn Y <br /> FABRICATE AND/OR PROVIDE AN ADAPTER BOX FOR DIFFUSER TO PERMIT SIDE 350 D I E <br /> CONNECTION OF FLEXIBLE DUCT. <br /> J. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH LANDLORD'S 2 F-16X14 <br /> FIELD REPRESENTATIVE. 350 <br /> K. PROVIDE SUPPORT FOR PIPIN6 ON ROOF PER LANDLORDS ROOFIN6 CONTRACTORS <br /> RECOMMENDATIONS. <br /> I 2 :&4 <br /> L. ALL EXI5TIN6 HVAC EQUIPMENT, PIPING, DUGTWORK, DIFFUSERS AND PLUMBING <br /> FIXTURES NOT INDICATED TO BE REUSED, SHALL BE REMOVED AND D15GONNEGTED 4 <br /> FROM ALL UTILITIES COMPLETE. VERIFY ON SITE. B-12 B-12 -12 <br /> 373 <br /> 5 3-15 375 0 <br /> B-12 .2- <br /> M. DRAWIN65 AND SPECIFICATIONS ARE TO BE GON51DERED A5 5UPPLEMENTIN6 EACH 375 S C) <br /> cn <br /> OTHER. WORK SPECIFIED BUT NOT 5HOWN ON DRAWIN65, OR 5HOWN ON DRAWIN65 <br /> BUT NOT SPECIFIED, SHALL BE PERFORMED OR FURNISHED AS THOU6H MENTIONED IN <br /> BOTH SPECIFICATIONS AND DRAWIN65. IF NOT OTHERN15E DIRECTED, INSTALLATION <br /> OF ALL SYSTEMS AND EQUIPMENT SHALL BE IN ACCORDANCE WITH APPLICABLE W W <br /> CODES AND IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. (2)D-24X24 <br /> WHERE WORK DESCRIBED IN THE SPECIFICATIONS 15 IN CONFLICT WITH THE WORK 1500 <br /> 5HOWN ON THE DRAWIN65, THE CONTRACTOR SHALL SUPPLY THE 6REATER QUANTITY, <br /> QUALITY AND G05T VIA THE BID AND CONTACT THE ENGINEER FOR CLARIFICATION I MIN <br /> N <br /> ON DIRECTION PRIOR TO INSTALLATION. Q Q N < Q <br /> co <br /> _ _ _ _ _ cn _0 <br /> N. LANDLORD PROVIDED DUCT DETECTOR IN SUPPLY AIR DUCT. TENANTS CONTRACTOR nN Q cvo <br /> SHALL WIRE DUCT SMOKE DETECTOR TO BUILDING FIRE ALARM CONTROL PANEL OR <br /> FURNI5H AND INSTALL A REMOTE AUDIBLE/VI5UAL ALARM DEVICE WITH A REMOTE F m E <br /> TEST 5WITGH LOCATED IN AN APPROVED LOCATION. FIELD VERIFY EXACT j li I _j <br /> REQUIREMENTS. CONTRACTOR SHALL TEST SYSTEM TO INSURE PROPER FUNCTION 1 114/14 14/14 <br /> PRIOR TO TENANT OGGUPYIN6 SPACE. I 10/14 10/14 o o <br /> Q <br /> o 2 RTU Q Q o <br /> N <br /> co <br /> N N S N N o co <br /> 0 <br /> 4 3 "' <br /> un Qn <br /> 0 <br /> B-12 B-12B-12 B-12 <br /> 375 37I 5 375 375 <br /> a.� <br /> UW cm <br /> Y <br /> O N c N <br /> L L <br /> (2)D-24X24 AF <br /> — <br /> 1500 <br /> FAMILY DOLLAR <br /> 0-24XI2 <br /> 300 <br /> B-12 B-12 B-12 B-12 I jll <br /> rte= 375 375 N 375 375 NI■ I 11111I <br /> CONTRACTOR SHALL HAVE THE OPTION TO �� ..do II, <br /> 5UB5TITUTE ROUND SPIRAL LOCK SEAM DUCT OF IN I ARCHITECTS, INC. <br /> EQUIVALENT 51ZE AND PERFORMANCE FOR <br /> FIRE PROTECTION ST�NDl�RDS REGTAN6ULAR DUCT. SPIRAL DUCT IN CONGEALED < < 17710 Detroit Avenue <br /> LOCATIONS AND IN STOCK ROOM SHALL BE o -Q Lakewood, Ohio 44107 <br /> A. THE CONTRACTOR SHALL RETAIN AND PAY FOR A "PROFESSIONAL OF RECORD" EXTERNALLY INSULATED. SEE 5PEGIFIGATION5 SHEET N - <br /> FOR ALL FIRE SPRINKLER AND FIRE PROTECTION WORK. THE DRAWIN65 AND ALL MP3. DUGTWORK IN OPEN DECK AREAS 15 NOT N N Phone ( 34 <br /> SPECIFICATIONS FOR ALL FIRE PROTECTION WORK ARE PERFORMANCE IN SCOPE REQUIRED TO BE INSULATED. 14/14 14/14 Fax (2116)6) 5211-482-482 4 <br /> AND INTENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DE516N, LAYOUT, 10/14 10/14 www.adaarchitects.cc <br /> DETAILS, DRAWIN65, DOCUMENTS, MATERIALS, EQUIPMENT, LABOR, AND ALL — — <br /> CRITERIA TO MEET GOVERNING AUTHORITIES, CODES, REGULATIONS, AND d 2 RTU Q <_ <br /> UNDERWRITER'S REQUIREMENTS FOR ALL FIRE PROTECTION WORK. CONTRACTOR NOTE CONTRACTOR: Cl 4 2 S — D <br /> SHALL VISIT THE 51TE TO BECOME FAMILIAR WITH THE EXI5TIN6 CONDITIONS PRIOR N N cv N <br /> TO 5UBMITTIN6 BID. A COMPLETE SET OF ALL REQUIRED DOCUMENTS SHALL BE DUGTWORK SHALL BE 51ZED AND INSTALLED A5 INDICATED ON — <br /> CONTRACT DOCUMENTS. NO GHAN6E5 SHALL BE MADE WITHOUT PRIOR <br /> PREPARED AND SUBMITTED TO THE PROPER AUTHORITIES WITHIN THIRTY (30) DAYS )FESS <br /> WRITTEN APPROVAL FROM TENANT. FAILURE TO DO 50 SHALL RESULT � � <br /> OF CONTRACT AWARD. THE LANDLORD'S DE516N CRITERIA SHALL BE GON51DERED I M. s?" <br /> IN CONTRACTOR REMOVIN6 INSTALLED 5Y5TEM AND REPLAGIN6 WITH <br /> PART OF THESE STANDARDS. NEW A5 SHOWN AT NO ADDITIONAL G05T TO TENANT. MINOR DUCT 1 3 375-12 p� <br /> GHANC,E5 DUE TO EXACT UNIT LOGATION5 OR ORIENTATION SHALL BE M33481 in <br /> B. ALL FIRE PROTECTION WORK SHALL BE 5GHEDULED IN ADVANCE WITH THE ACCEPTABLE. B-12 B-12 B-12 m <br /> LANDLORD'S FIELD REPRESENTATIVE. FIRE PROTECTION SYSTEM SHALL BE FULLY -24X12 375 375 375 <br /> OPERATIONAL WHEN THE CONTRACTOR 15 OFF THE SITE. 12_ <br /> 00 * +" <br /> (2)0-24X24 o.a.a.zaaz. s 95DUAC9 <br /> G. WHERE GEILIN65 OR GEILIN6 6RI05 ARE EXI5TIN6 TO REMAIN OR NEW GEILIN65 NOTE_ WAG S, 000a,sso.c FU5oA es <br /> ARE INSTALLED AND NEW L16HTIN6 CONFLICTS WITH THE LOCATION OF EXI5TIN6 CONTRACTOR SHALL REFER TO THE EM SHEETS FOR INSTALLATION 1550 oate:zox". - 34-06W <br /> SPRINKLER HEADS, THE NEW L16HTIN6 SHALL BE SHIFTED APPROXIMATELY 6 (OR CCl t 111612020 <br /> �� INSTRUCTIONS FOR THE VENDOR FURNISHED, CONTRACTOR INSTALLED 14/14 <br /> A5 REQUIRED TO MAINTAIN CLEARANCE TO SPRINKLER HEADS PER NFPA 13) TO HVAC CONTROL SYSTEM AND TEMPERATURE AND G02 5EN50R <br /> ALLOW THE EXI5TIN6 SPRINKLER HEADS TO REMAIN. LOGATIONS PRIOR TO THE INSTALLATION OF ALL RELATED ITEMS. <br /> D. CONTRACTOR SHALL MODIFY EXI5TIN6 SPRINKLER PIPIN6 AND HEADS A5 REQUIRED Q 2 RTU ° 6 <br /> FOR RE-DEMI5ED SPACE. IF AN EXI5TIN6 SPRINKLER HEAD 15 UNIN5TALLED FROM <br /> THE EXI5TIN6 SYSTEM, IT CANNOT BE REINSTALLED PER NFPA 13. NOTE: 4 I a <br /> ROOF WORK FLA5HIN6 FOR HVAC EQUIPMENT, PLUMBIN6 VENTS, B-12 B-12 L B-12 B-12 <br /> 6ENERAL SPRINKLER NOTES PENETRATIONS, ETC., SHALL BE PER LANDLORD'S ROOFIN6 500 500 500 500 LO <br /> CONTRACTOR'S REQUIREMENTS TO MAINTAIN ROOF WARRANTEE. O <br /> I. MODIFY EXI5TIN6 SPRINKLER SYSTEM A5 REQUIRED TO ACCOMMODATE THE FLOOR N m <br /> PLAN. Q �_ N _< �_ O ti <br /> HVAC, SYSTEM SHALL BE CONTROLLED BY Q Q Q 0 <br /> 2. SHOP DRAWIN65 OF THE SPRINKLER SYSTEM MODIFICATIONS SHALL BE PREPARED BY ENER6Y MANAGEMENT SYSTEM. EMS SYSTEM N N _N N O <br /> THE CONTRACTOR AND SUBMITTED TO THE APPROPRIATE DEPARTMENTS OF THE COUNTY TO BE PROVIDED BY TENANT FOR TENANTS 14/14 18/16 18/16 14/14 <br /> FIRE INSPECTION DIVISION, STATE FIRE MARSHALL, INSURANCE UNDERWRITERS, j 00 <br /> C,ONTRAC,TOR INSTALLATION. I� m <br /> MECHANICAL EN61NEER AND ANY OTHER OFFICES HAVIN6 JURISDICTION OVER THE 00 <br /> SPRINKLER SYSTEM. THE CONTRACTOR SHALL RECEIVE WRITTEN APPROVALS PRIOR TO �1 <br /> PERFORMING ANY MODIFICATIONS. <br /> d < < <br /> MEGHANICAL LEGEND Q o <br /> 3. THE CONTRACTOR SHALL SUBMIT THE APPROVED SPRINKLER DRAWIN65 TO THE — — — — <br /> LANDLORD PRIOR TO MAKING ANY MODIFICATIONS. CONNECTION TO EXI5TIN6 SERVICE 4t <br /> D-24X 12 <br /> 4. THE CONTRACTOR SHALL EXTEND THE SPRINKLER SYSTEM AND PROVIDE DRY PENDANTAPPROVED DUGT TYPE SMOKE DETECTOR 300 <br /> HEADS IN WALK-IN COOLER AND FREEZER SECTIONS PER NFPA 13 REQUIREMENTS. 0 N <br /> ® <br /> ° CARBON DIOXIDE 5EN50R "' <br /> J m <br /> 51TE UTI L I TI E5 RTU TAC, EQUIPMENT TA6 5010 5012 5010 5010 w z z <br /> No. _ <br /> (FIRE, DOMESTIC WATER, SEWER, 6A5, STORM) U) o <br /> A - 10 X 10 TA6 - NECK 51ZE J U <br /> I. CONTRACTOR SHALL VERIFY POINT OF CONNECTION TO 51TE UTILITY AIR DEVICE TA6 J O v <br /> H - Q } <br /> SERVICE PRIOR TO COMMENCING INSTALLATION. 300 VOLUME GFM co <br /> SUPPLY AIR DIFFUSER N w= <br /> 2. CONTRACTOR SHALL ADJUST LOCATION AND DEPTH OF BUILDIN6 I I I I I I I Q Q z <br /> SERVICES A5 REQUIRED TO CONNECT TO 51TE UTILITY SERVICE. Z OR ® RETURN/EXHAU5T AIR 6RILLE I I I I I 0 Q Q <br /> 3. CONTRACTOR SHALL MAKE FINAL CONNECTION TO SITE UTILITY RFD r J w <br /> RATED FIRE DAMPER I I I I I Q O <br /> SERVICE (UNLESS OTHER PROVISIONS HAVE BEEN MADE). — Q <br /> I VOLUME DAMPER I I I I I O = <br /> 4. CONTRACTOR'S FAILURE TO PROPERLY COORDINATE SERVICES SHALL NOT LAV TA6 - NO. PLUMBIN6 FIXTURE TA6 J — <br /> BEJUSTIFIGATIONFORANYEXTRAGHAR6E5. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - a O MQ <br /> C'j LL <br /> 6/6 NEW SUPPLY, RETURN AND EXHAUST AIR U cY3 <br /> DUCTWORK - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> 6/ NEW SUPPLY, RETURN AND EXHAUST AIR <br /> DUCT ELBOW UP <br /> X 6/ NEW SUPPLY, RETURN AND EXHAUST AIR <br /> DUCT ELBOW DOWN� Q) <br /> � NEW FLEXIBLE DUCT _ O <br /> U � <br /> 6/b EXI5TIN6 SUPPLY, RETURN AND EXHAUST Q OQ <br /> AIR DUGTWORK <br /> 86/b EXI5TIN6 SUPPLY RETURN AND EXHAUST FAMILY DOLLAR HVAG PLAN O0 <br /> AIR DUCTWORK T'O BE DEMOLISHED a D <br /> IF YOU HAVE ANY QUEST I ONS RE6ARD I N6 THE SCALE: 1/S" = 1'-0" <br /> MEGHANIGAL PLANS, PLEASE CALL THE ---- ARE EXDI5TIN6 TO BE RELOGA EDDPENORTH sheet <br /> MEGHAN I GAL DES I GNER. —N6— NATURAL 6A5 (NEW) <br /> EN6 NATURAL 6A5 (EXI5TIN6) <br /> DES16NER: SEAN MOYER _CD_ AIR GONDITIONIN6 CONDENSATE <br /> PHONE/FAX: 612-465-7278 <br /> E-MAIL: Seon.moyer©dunhomeng.com <br />