Laserfiche WebLink
rn <br /> IF �1 �I �I I I�,t �I L1 III � <br /> PLANS PLEA ENGALL THEELECCTRICAL DE516NER.GTRIGAL LIOHTI I 6 FLAIL NOTES LUI�I I LUMINAIRE S�il-TEDULE LO �, <br /> L16HT FIXTURES PROVIDED BY TENANT POR TENANT'S GONTRAGTOR IN5TALLATION s o 1 <br /> DE516NER: RICK MOMBER6 <br /> PHONE/FAX: 612-465-7627/612-465-7776 PER SECTION 5.4.2 MULTI-LEVEL 5WITGHIN6 O EXIT 516N5: CONNECT TO THE LINE 51DE OF LOCAL 5WITGHIN6 AND GONTAGTOR OR <-----------------LAMPS---------------a LT6. FIXT. C o '2 ci <br /> E-MAIL: rick.momber �dunhamen com CONNECT TO DE516NATED N16HT L16HT GIRGUIT. FIXTURE L16HT G o r <br /> 9 9 NOT REQUIRED WHEN THE LIGHTING POWER A. IN 5TOGKROOM INSTALL WALL MOUNTED TYPE ON WALL CENTERED 1'-0" ABOVE THE SYMBOL DE5GRIPTION VOLTS INPUT QTY. - MOUNTING SCHEDULE NOTES r o <br /> DENSITY 15 LE55 THAN 0.5 W/ft�. DOOR OPENIN6. WATTS WATTS TYPE. o .9 LL <br /> B. IN 5ALE5 AREA MOUNT ON WALL ABOVE DOOR. rA '0 <br /> 3 4 z `J 4'-0" NARROW 5TRIP L16HT SEE IS I-17W FURN15HED W/ GEILIN6 INTERIOR/ EXTERIOR m - <br /> 5TOGKROOM = 1088 ft Q v 6 <br /> (6) LI6HT5 x 36w/ea. = 216 watts O CONTRACTOR SHALL 5U5PEND L16HTIN6 IN TH15 AREA FROM THE BELECT. LED FIXTURE SURFACE STRIP BOTTOM OF EXI5TIN6 PANEL NOTES: A G D 6. " a) � �' <br /> TOTAL = 216 watts A55 REQUIRED. FIIXTURE5 SHALL BE 16HTIN6 AT 1O I MIGALLRAFF. PROVIDE Y RE5TRAI ED WHEREEREQU RED BY LOCAL � L W + <br /> CODE AUTHORITY. 4-0NARROW 5TRIP L16HT 5EE IS I-17W FURN15HED W/ GEILIN6 INTRJ EXTR. STRIP a y <br /> 216w / 1088 ft' = 0.20 W/ft2 LU (EMER6ENGY L16HT) ELECT. LED FIXTURE 5URFAGE L16HT W/EMER6. E <br /> OPROVIDE ROU6H IN FOR TENANT 5TOREFRONT 516N(5) AND AWIN6 WHERE APPLIGABLE. PANEL INVERTER BACK-UPm = <br /> MULTI-LEVEL 5WITGHIN6 NOT REQUIRED. FINAL GONNEGTION5 WILL BE FURN15HED AND INSTALLED BY TENANT'S 516N CONTRACTOR. NOTES: A, G, D, 6, S H. ❑ c rn C o m <br /> FURNI5H AND INSTALL JUNCTION BOXES W/6' WHIP ON WALL ABOVE AGGE551BLE GEILIN6. p a E <br /> CONTRACTOR 5HALL COORDINATE FINAL JUNCTION BOX LOCATION WITH 516N VENDOR. Cp 4'-0" NARROW STRIP L16HT 5EE 18 I-17W FURN15HED W/ GEILIN6 INTR./ EXTR. STRIP <br /> JUNGTION BOXES NEED TO BE WITHIN 5 FEET OF 516N FOR 516N VENDOR TO MAKE FINAL <br /> - - - - - - - -- /q ELECTRICAL CONNECTION. ILU (EMER6ENGY BALLAST) ELECT. LED FIXTURE 5URFAGE LIGHT W/EMER6. BATT <br /> PANEL BACK-UP <br /> IF STORE HA5 ADDITIONAL 51DE OR REAR 516NA6E THE CONTRACTOR SHALL COORDINATE NOTE: A, G, D, E, 6, 4 I. <br /> WITH THE 516N VENDOR FOR ANY ADDITIONAL EXTERIOR 516NA6E AND THE A550GIATED 4'-0" NARROW STRIP LIGHT 5EE 36 2-17W FURNISHED W1 GEILIN6 INTRJ EXTR. STRIP <br /> ELECTRICAL REQUIREMENTS. AFTER THE ELECTRICAL DE516N 15 GOMPLETE, IT MAY BE <br /> DETERMINED THAT CERTAIN 51TE5 REQUIRE 51DE OR REAR 516NA6E. <br /> LU (EMER6ENGY BALLAST) ELECT. LED FIXTURE 5URFAGE LIGHT WIEMER6. BATT <br /> �ti O CONTRACTOR TO IN5TALL NEW TENANT 5UPPLIED INVERTER BELOW EMS PANEL ON WALL PANEL BACK-UP <br /> EM5 <br /> 1\ ����� PER MANUFAGTURER5 IN5TALLATION IN5TRUGTION5 AND DETAIL5 ON THR5E PLAN5. NOTE: A, G, D, E, 6, I. <br /> G PANEL LI INVERTER TO BE EISMIGALLY SUPPORTED AS NECESSARY. 6-0" NARROW 5TRIP L16HT 5EE 3(9 2-17W FURN15HED W/ GEILIN6 INTERIOR/ EXTERIOR o <br /> PANEL PI ELECT. LED FIXTURE 5URFAGE 5TRIP <br /> O5 IN5TALL WALL PACK FIXTURE ABOVE EXTERIOR DOORS AT 10'-0", COORDINATE <br /> PANEL HI <br /> / EXACT MOUNTIN6 HE16HT AND LOCATION. PANEL NOTE5: A, G, D, $ 6. C) <br /> /EX15TINC75PENDED 75kVA XFMR 4 pcn <br /> _ DAMP <br /> O TO NORMA=1 NOTED LUPOWER. BOH LAMPS 5HARE HE 5ARE 5HALL HAVE ONE LAMP ME NEUTRAL RAND 6ROUNDINVERTER AND ONELGIRGUITRLIUIB D <br /> K SHALL BE U5ED FOR THESE FIXTURES AND SHALL BE ON THE EMPLOYEE GONTAGTOR OF <br /> Oj LI-5LI-5 VIA I X J II THE ENERGY MANA6EMENT 5Y5TEM. 5E INVERTER WIRING DIAGRAM ON THI5 SHEET. z 6-0" NARROW 5TRIP L16HT EE 36 2-17W FURN15HED W/ GEILIN6 INTRJ EXTR. STRIP <br /> EM5 w LI-5 O EXI5TIN6 BUILDIN6 L16HTIN6 TO REMAIN. LIGHTING GIRGUITED AND CONTROLLED BY (1116HT L16HT) ELECT. LED FIXTURE 5URFAGE NOTES: A, G, D, F, 6. <br /> LANDLORD HOUSE PANEL AND GONTROL5. PANEL <br /> .TOILET...- �� � TOILE <br /> LU LU O 1 z _ O PC). OOCCUPANCY SENSORS: INSTALL "6REEN6ATE" OCCUPANCY SENSOR CATALOG <br /> STORAGE/ EMB MB- LI-2q #ONW-D-1001-DMV-W ON WALL NEXT TO DOOR. 5EN50R TIME DELAY TO BE 5ET TO 5 <br /> STOCKROOM 12 ABLE MINUTE5. OCCUPANCY 5EN5OR5 PROVIDED BY TENANT FOR GONTRAGTOR5 INSTALLATION. <br /> _2 . _ 5EE DETAIL 3/E2.1 FOR WIRING DIA6RAM. m 8'-O" NARROW STRIP L16HT 5EE 36 2-17W FURN15HED W/ GEILIN6 INTRJ EXTR. STRIP o <br /> -_ -_ = os os w (EMER6ENGY BALLAST) ELECT. LED FIXTURE 5URFAGE LIGHT W/EMER6. BATT N Y <br /> U-1IS g g O PROVIDE FLEXIBLE CONNECTION TO L16HT FIXTURES AT EXPAN51ON JOINT. PANEL BACK-UP E <br /> (TYPICAL) N ° NOTE: A, G, D, E, 6, I. <br /> LID LI-6 NL to MOUNT EMER6ENGY FIXTURE ABOVE DOOR APPROXIMATELY 10'-0" AF6. COORDINATE WITH <br /> 17 EXISTING CONDITIONS, AWNIN65 AND/OR 516NA6E. LOCATE REMOTE BATTERY ABOVE <br /> OFFICE. GEILIN6.k4l y 6-0" NARROW STRIP L16HT EE 36 2-17W FURN15HED W/ GEILIN6 INTRJ EXTR. STRIP <br /> Li I LI-6 VIA EM5 <S> KEYED 5WITGH FOR MANUAL CONTROL OF L16HTIN6 IN 5TOGKROOM. E.G. TO FURNI5H AND w (EMER6ENGY LIGHT) ELECT. LED FIXTURE 5URFAGE LIGHT W/EMER6. <br /> INSTALL IN LOCATION 5HOWN AND WIRE PER DETAIL 2/E2.1. PANEL INVERTER BACK-UP <br /> z NOTES: A, G, D, 6, $ H. <br /> _ - - _ - - - 12 LOCATION OF EM5 L16HTIN6 MANAGEMENT CONTROLLER WITH MANUAL CONTROL OF <br /> L16HTIN6. COORDINATE 2-HOUR BYPA55 PRO6RAMMIN6 OF AUTO-OFF PER TITLE 24 SEG. <br /> 131(d)2. 5EE "EM" DRAWIN65 FOR ADDITIONAL INFORMATION. MANUAL OVERRIDE DIMMING <br /> 5WITGHE5 AND OWOFF 5WITGHE5 ARE BACKLIT FOR NOTIFICATION TO OPERATOR. 5EE LED WALL PACK EE 40 40W LED FURN15HED W/ WALL U.L. L15TED FOR NET <br /> LI IS EM LI-4 q L-IS EM J 'OFFICE ELEVATION' 2/EI.I FOR MOUNTIN6 HEI6HT5 FOR 5WITGHE5. 0 ELECT. FIXTURE MOUNTED LOGATION5 NOTE-5 Q <br /> LI-IS EM 13 ALL EM5 CONTROLLED L16HTIN6 WILL HAVE PRESET ON/OFF TIMES A5 WELL A5 MANUAL PANEL OYER DOOR N <br /> CONTROL, AND OPTIONAL OVERRIDE 5WITGHIN6 LOCATED IN MANA6ER5 OFFICE. 5EE 2/EI.I ® EXIT LIGHT EE 5 LED LAMP ARRAY GEILIN6 L.E.D. 51N6LE- <br /> FOR 5WITGH LOGATION5. ELECT. FURN15HED W/ FIXTURE MOUNT, UNLE55 FACE EXIT 516N <br /> LI IS VIA EM5 1I-4 IA EM I4 L16HT FIXTURE5 IN THI5 AREA SHALL BE DIMMABLE PER TITLE-24 DIMMIN6 REQUIREMENT5 PANEL REQ'D BY W/EMER6. BAT. <br /> 11141 TRTER CODE NOTE: D 8 I. <br /> 15 FOR "EMB" EMER6ENGY L16HTIN6 GONNEGT BOTH A 5WITGHED AND UN5WITGHED CIRCUIT MOUNT REMOTE EMER6ENGY 5EE 2 (2) 1.5 WATT 12 LED ARRAY LAMPS EXTERIOR EXTERIOR EMER6ENGY <br /> LI-3 q LE6 FROM 5AME CIRCUIT THAT 5ERVE5 LIGHTING 50 THAT FIXTURE 15 GONTOLLED BY LIC OUT5IDE ABOVE EXIT ELECT. FURN15HED W/ FIXTURE WALL LIGHT WITH REMOTE <br /> 5WITGHED CONDUCTOR AND THE BATTERY GHAR61% AND 5EN51% ELEMENTS ARE <br /> CONNECTED TO UNSWITGHED CONDUCTOR. FIXTURE WILL ILLUMINATE ON POWER FAILURE. DOOR5 W/ BATTERY UNIT IN51DE PANEL BATTERY <br /> BLD6. NOTES: E $ I. <br /> I6 PER T24 T141.0-E, 5ALE5 AREA L16HTIN6 FALLS BELOW THE 585% OF THE ca <br /> ALLOWANGE5 5ET FORTH IN EGTION 14O.6(G)2. A5 A RE5ULT DAYLI6HTIN6 HIGH-POWERED 5EE 3.5 (2) 3.3 WATT 3 LED ARRAY LAMP5 WALL OR EMER6ENGY L16HT � <br /> 13 14 GONTROL5 ARE NOT NEGE55ARY. EMER6ENGY L16HT ELECT. FURN15HED W/ FIXTURE GEILIN6 WITH BATTERY NOTES: .N Y <br /> PANEL 5URFAGE E $ I. a� co <br /> _ OCCUPANCY <br /> DMV-W ONSNALL. 5EN50R TIME DELAY TO BE 5ETTO15 M NUTE5. OGGUPANGY L <br /> q - - - - D EMER6ENGY L16HT 5EE 400W ---NA--- FLOOR OR 5UPPLIED BY TENANT, <br /> LI IS EM LI-4 L-IS EM 5EN50R PROVIDED BY TENANT FOR CONTRACTORS INSTALLATION. 5EE DETAIL 4/E2.1 FOR ® <br /> WIRING DIAGRAM. INVERTER UNIT ELECT. -OR- WALL INSTALLED BY E.G. <br /> LI-I EM <br /> PANEL 720W o a <br /> LU <br /> LI6HTIN6 FIXTURE 5GHEDULE NOTES: o <br /> 0 <br /> (TYPICAL) B. <br /> DE516NATED FIXTURE SHALL HAVE LED LAMPS o <br /> 0 <br /> q I B. GUT INSULATION (WHEN BATT TYPE 15 U5ED) OR PROVIDE 5HIELD AROUND FIXTURE (WHEN BLOWN-IN TYPE 15 U5ED) TO KEEP INSULATION A <br /> LI-3 ERm o� RE5TROOM MINIMUM OF 3" AWAY FROM FIXTURE. <br /> LIGHT <br /> G. ATTACH FIXTURE TO T-BAR PER GEG 410-36 WHERE APPLICABLE. <br /> �,r,K D. FIXTURE PROVIDED WITH DUAL VOLTA6E 120/277V POWER 5UPPLY. a U <br /> RED EMB E. L16HT FIXTURE 5HALL HAVE BATTERY BACK-UP WIRED AHEAD OF 5WITGHE5/GONTAGTOR5 ON 5AME GIRGUIT. UNIT EQUIPMENT SHALL BE PER (D (D � <br /> MITE o LI-� GEG 700.12F. c CL- � � � <br /> o o �� UNSWITGHED HOT FOR EM BALLA5T <br /> q � o o F. L16HT FIXTURE SHALL REMAIN ON DURIN6 NON-BU51NE55 WORKIN6 HOURS. <br /> TLI IS EM LI-4 L"IbEM r�t0 6. WITH NO FIN15HED GEILIN6, L16HT FIXTURES IN THE 5ALE5 AREA SHALL BE 5U5PENDED ® 12'-0" A.F.F. AND L16HT FIXTURES IN THE <br /> LI-IS EM - 5TOGKROOM AREA 5HALL BE 5U5PENDED @ 10'-0" A.F.F. <br /> C cam. ONW-D-1001-DMV-W <br /> C HOT H. EMER6ENGY FIXTURE WIRED FROM INVERTER GAPABLE OF PROVIDIN6 q0 MINUTE MINIMUM BATTERY BACK-UP. - 4�1 <br /> LI-2q I. PROVIDED WITH q0 MINUTE MINIMUM BATTERY BACK-UP. I I <br /> 411 <br /> NEUT. 111111 1 <br /> GOMMON II�� SII <br /> q EXHAU5T FAN All1 <br /> IL <br /> LI-3 40 ARCHITECTS, INC. <br /> ADJACENT TENANT <br /> SPACE ( ) RED CD RED o� <br /> 41 MERCANTILEILE USE LIGHTING 17710 Detroit Avenue <br /> GROUP M 1 1 RE5TROOM 1 1 Lakewood, Ohio 44107 <br /> BLACK RED L16HT BLACK RED EMB Phone (216) 521-5134 <br /> Fax (216) 521-4824 <br /> WHITEo o BLUE EMB WHITE o o BLUE L1_29 www.adaarchitects.cc <br /> q LI 18 EM LI-4 L-18 EM q GREEN 1 0 o GREEN 1 0 o J%AITGHED HOT FOR EM BALLA5T <br /> LI-I EM O UNSWITGHED HOT FOR EM BALLAST LI-29 O <br /> 0 0 <br /> ONW-0-1001-DMV-W ��, ONW-D-1001-DMV-W <br /> ( FAMI Y DOLLAR SA ES AREA PIGAL) f LI-2a HOT LI-2qHOT0� <br /> NEUT. I NEUT. � R kp <br /> q <br /> LI-3 t <br /> I I O��I G� OGGUi��NGY SENSOR(S)BATHROOM OGGUi�ANGY SENSOR NO SCALE <br /> NO SCALE DN CN..1ay D Ron�. , 80225C00009A 1. <br /> D��U C-US <br /> Date:2?On-01.15 <br /> q 1�15�2020 <br /> LIIS EM LI-4 L-18 EM <br /> LI-IS EM <br /> NO E: EMS TIMED E.C. TO FURNISH AND INSTALL KEYED SWITCH IN LOCATION <br /> ^ BYPASS SHOWN FOR CONTROL OF STOCKROOM LIGHTING. PROVIDE a <br /> V E.G. 15 RE5PON51BLE TO FURNI5H, INSTALL, AND TERMINATE ALL O-IOV CONTROL WIRIN6 (2) KEYS TO TENANT UPON COMPLETION. <br /> q PER G.E.G. AND STATE ENER6Y GODE5 FOR ALL L16HT FIXTURES THAT UTILIZE O-IOV LEVITON CAT. NO. #1221-2WL OR EQUALS C-0LI-3 m <br /> DIMMING A5 MARKED ON PLAN5. COORDINATE INSTALLATION WITH EM5 5Y5TEM 5UPPLIER. K STOCKROOM / STORAGE LTG LO <br /> HOT / NORMAL LAMP ------------ o <br /> EMS <br /> LI-5 CONTACTORUN5WITCHED EM BALLAST POWER EMB FIXTURES ONLY I I OO <br /> 13 T. I I 0 <br /> 14 NEUT. -----------J O <br /> C>0 <br /> LI-18 ETM LI-4 q L-18 EM00 <br /> W-T LI-18 EM <br /> H <br /> b EMS TIMED E.C. TO FURNISH AND INSTALL KEYED SWITCH IN LOCATION 0 <br /> BYPASS SHOWN FOR CONTROL OF STOCKROOM LIGHTING. PROVIDE <br /> (TYPICAL) TS (2) KEYS TO TENANT UPON COMPLETION. <br /> LEVITON CAT. NO. #1221-2WL OR EQUALS J <br /> I q K STORAGE / LOADING DOCK LTG W a� <br /> LI-3 HOT / NORMAL LAMP �J <br /> -----------� \ l � <br /> E9 EMS <br /> LI-5 CONTACTOR I I n n���III J <br /> UN5WITGHED EM BALLA5T POWER (EMB FIXTURE ONLY) I _I U <br /> NEUT. LJJ <br /> z I6 z NU5 0 <br /> EUT. < <br /> I J U CL <br /> J <br /> LI IS EM LI-4 q L-IS EM Q <br /> 1--- Z <br /> N � <br /> LI-IS EM EBYPASSD Q <br /> 10 I 10 10 I H TS I� J <br /> LI-21 I j-2I LI- <br /> _ INVERTER _ NORMAL LAMP HOT ----------- Q v <br /> 5WITGHED HOT (PROVIDED BY NORMAL LAMP (NEUT)I O = J <br /> EMS I TENANT FOR <br /> CONTACTORI 2-LAMP EMERGENCY FIXTURE I a Q co LU <br /> HOT UN-5WITGHED HOT I INSTALLATION BY 15NITCHED HOT (EM) EMER6ENGY LAMP (HOT), I U M < W <br /> 7 CONTRACTOR) I NEUT. EMER6ENGY LAMP NEUT. <br /> - - - - - - - I _ NEUT. NEUT. LGO <br /> - - - - - - - - � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -fib- - _ _� � <br /> J J J II - - <br /> 7 <br /> y� - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - t ' LIGHTING CONTROL OVERRIDE (LCO) IS A FACTORY INSTALLED NORMALLY Ocm <br /> TO 516N 3 3 CLOSED CONTACT. REFER TO MANUFACTURES INSTRUCTIONS FOR 0\ �o ) <br /> O LI-25 TO SIGN TO SIGN CONNECTION REQUIREMENTS. IT IS THE SYSTEMS INTENT THAT THE CONTACT / L <br /> 3 OPENS IN EMERGENCY MODE ELIMINATING THE 0-10V DIMMING CONTROLS TO E O ca <br /> Ji FIXTURES ALLOWING THEM TO OPERATE AT FULL BRIGHTNESS. , _ Q <br /> LL, _j �p O IOV O-IOV O-IOV O-IOV O-IOV <br /> EMS 0-10V O-1Ov O-1Ov O-1Ov O-IOV_/ sheet <br /> DIMMING CONTROL <br /> I.AM L'i' DOLLAR L16HTIN6 LNCANT NCS GONTROLS AND INVERTER NCS AGRA S � <br /> NO 5GALE <br />