My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2020 2:25:24 PM
Creation date
8/20/2020 2:28:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
FACILITY_NAME
Shell Oil Products US - Stockton Terminal
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A J OA U I Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Shell Oil Products US - Stockton Terminal 3515 Navy Dr, Stockton September 26, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The owner/operator failed to sign the following designated inspection report under section VI within 48hours. <br /> The Designator operator(DO) inspection report of 8/21/19 was signed on 9/3/2019, 11 days late. <br /> The DO report of 7/22/19 was signed on 9/3/19, 40days late <br /> The DO report of 6/21/19 was signed on 9/3/19 ,72days late <br /> The DO report of 5/22/19 was signed on 9/3/19, 102 days late <br /> The DO report of 3/22/19 was signed on 3/25/19 , i day late <br /> The DO report of 2/21/19 was signed on 2/27/19 , 4days late. <br /> The DO report of 11/20/18 was signed on 11/28/18, 6days late. <br /> The owner/operator acknowledgment of compliance is required within 48 hours of the date of the designated UST <br /> operator inspection report. <br /> During the monthly inspection, the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and document the dates they were done. Ensure that designated operators <br /> performing monthly inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> The spill container when tested did not hold 5 gallons. All USTs shall be equipped with a spill container that collects <br /> any hazardous substances spilled during delivery operations, that has a minimum capacity of five gallons and a <br /> drain valve that allows drainage of the collected spill into the primary container or provide a means to keep the <br /> container empty. Immediately contact a properly licensed, trained, and certified contractor to install an approved <br /> spill container under permit and inspection of the EHD. If a spill container can't be installed immediately, there is a <br /> possibility that the UST system may be red tagged to prevent fuel inputs. <br /> This is a minor violation. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Overfill prevention testing has not been conducted. This testing was required to be conducted by October 13, 2018. <br /> Immediately schedule this testing and provide 48 hours notification to the EHD. Ensure all future testing is <br /> conducted within required time frames. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by October 26, 2019. <br /> FA0003747 PR0231210 SCO01 09/26/2019 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.