Laserfiche WebLink
SANJOAQUIN Environmental Health Department <br /> —COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CANEPAS CAR WASH 6230 PACIFIC AVE STOCKTON June 03 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems(pre-Jan 1984). DV ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Financial responsibility documents have not been submitted to the EHD. The most recent financial responsibility <br /> documents are dated 04-12-2018. Current financial responsibility documents are required to be submitted annually. <br /> Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload <br /> the required documents. <br /> This is a minor violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the 87 product tanks are not current in CERS. Under tank configuration in 87 product <br /> tanks is incorrectly stated to have compartments. Both of the 87 product tanks are standalone tanks. Any change of <br /> information must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the required <br /> information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 115 CCR 2715(a)(1)(B), 2715(a)(3) "Designated Underground Storage Tank Operator Identification Form" not submitted <br /> within 30 days. <br /> Zane Nimmo is performing designated operator inspections at the facility and is not listed on the submitted statement <br /> of designated operators. Notification was not provided to the EHD within 30 days of the change. Any changes shall <br /> be reported to the EHD within 30 days. Immediately log into the California Environmental Reporting System (CERS) <br /> at http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is a minor violation. <br /> 124 CCR 2637.2(d&e), 2665(a&b) "Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days of <br /> inspection. <br /> Overfill prevention testing was performed on 8/29/18 and a test report was submitted on 11/30/18, 2 months late. A <br /> copy of the test report must be submitted within 30 days of the tests. Take all necessary precautions to ensure <br /> testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> FA0003624 PR0231225 SCO01 06/03/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />