EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6230
>
2300 - Underground Storage Tank Program
>
PR0231225
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2021 11:28:39 AM
Creation date
8/20/2020 2:38:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231225
PE
2361
FACILITY_ID
FA0003624
FACILITY_NAME
CANEPAS CAR WASH
STREET_NUMBER
6230
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
08136003
CURRENT_STATUS
02
SITE_LOCATION
6230 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ 0 A U I Environmental Health Department <br /> OUNT <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CANEPAS CAR WASH 16230 PACIFIC AVE, STOCKTON June 03, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The DO failed to check and note all required items on the visual inspection reports. <br /> The following was observed on the designated operator's monthly inspection reports: <br /> -Section II I of the report was left blank. <br /> -The "NA" in sections VII through XI were not explained. <br /> -Section V of the report was left blank. <br /> -Section VI of the report was missing the name of the owner/operator. <br /> -Section VII was left blank. <br /> -Page 2 of the report was left blank except for test dates. <br /> -Tank and line tightness test information was left blank. <br /> -The designated operator answered the question regarding sump sensor locations but did not list which sumps <br /> were visually inspected. <br /> -The designated operator documented visual inspections of sumps, but left blank the question regarding sump <br /> sensor locations. <br /> -The report failed to identify the designated operator. <br /> During the visual inspection, the designated operator shall check all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designed operators <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 215 CCR 2712(1) Failure to retain a copy of the permit to operate at the facility. <br /> A copy of the UST operating permit of 2019 was not found on site. A copy of the UST operating permit and all <br /> attachments and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on <br /> site. <br /> This is a minor violation. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> A small amount of liquid dripping from the fuel filter of UDC 11/12 was observed. All primary containment for the <br /> UST system must be tight. Immediately have a properly licensed, trained, and certified contractor repair or replace <br /> the failed component under permit and inspection of the EHD. <br /> This is a minor violation. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> Liquid was observed in the 11/12 UDC sump. If water could enter into the secondary containment by precipitation <br /> or infiltration, it must be removed and disposed of properly. Immediately remove this liquid, make a hazardous <br /> waste determination per Title 22 hazardous waste regulations, and manage it accordingly. Ensure that the UDC <br /> sump is maintained free of liquid. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> FA0003624 PR0231225 SCO01 06/03/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.