Laserfiche WebLink
SA N A O A Q U l N Environment s ment <br /> COUNTY— � 2a1r9 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#2120 9321 N THORNTON RD STOCKTON May 02 2019 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plans for both tanks do not include <br /> the UDC sensor manufacturer or model. The monitoring plan must be uploaded to the California Environmental <br /> Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> 118 CCR 2715(a)(1)(A), 2715(a)(2) Failure to submit the "Underground Storage Tank Statement of Understanding and <br /> Compliance Form". <br /> The Underground Storage Tank Statement of Understanding and Compliance Form was not found in CERS. This form <br /> must be uploaded to the California Environmental Reporting System (CERS). Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload the Underground Storage Tank <br /> Statement of Understanding and Compliance Form for this facility. <br /> This is a minor violation. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. Overfill prevention test results for <br /> 9/26/2018 were not found on site. These records shall be maintained on site for at least three years. Monitoring <br /> records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance <br /> records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of <br /> all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br /> inventory readings and reconciliations. Immediately locate and maintain all maintenance and monitoring records for <br /> the last three years on site. <br /> This is a repeat violation, Class II. <br /> 202 CCR 2715(c)(3), 2715(c)(4) Failure to maintain the "Facility Employee Training Certificate" on-site (after October 1, <br /> 2018). <br /> -The Facility Employee Training Certificates contained no CERS ID, no phone number, and the designated operator <br /> expiration date was incorrect. <br /> -The designated employee training conducted on 12/17/18 and 11/21/18 were on an outdated form. <br /> All site employees must be trained prior to taking responsibility as a facility employee if after October 1, 2018, or <br /> within 30 days of hire if prior to October 1, 2018. The Facility Employee Training Certificate shall contain accurate <br /> information for all employees trained. Update the Facility Employee Training Certificates to contain the accurate <br /> information and submit copies of the updated forms to the EHD. <br /> This is a minor violation. <br /> FA0002890 PR0231261 SCO01 05/02/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />