My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231289
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 2:18:11 PM
Creation date
8/20/2020 3:15:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231289
PE
2361 - UST FACILITY
FACILITY_ID
FA0003847
FACILITY_NAME
NORCAL FUELS
STREET_NUMBER
3300
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11705037
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
3300 N WEST LN STOCKTON 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN" J D�l+ �� I 11411" Environmental Health Department <br /> COUNTY— <br /> Underground <br /> �l O U N T Y— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WEST LANE FUEL 3300 N WEST LN STOCKTON Jul 02 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -The monitoring plans for both tanks left UDC sensor manufacturer and model blank. <br /> -The monitoring plans for both tanks list the panel as a TLS 350. The panel on site is a TLS 350 Plus. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(i)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to visually inspect the 87 STP sump for leaks,water, or debris during the 12/24/18 <br /> inspection; according to the designated operator report, the site had fuel alarms in the 87 STP sump on 12/10/18 and <br /> 12/11/18 that were addressed by employees removing rain water. During the inspection,the designated operator shall <br /> visually inspect all spill containers and UDC sumps, and any tank top sump that had an alarm for which there is no <br /> record of a service visit. Ensure that designated operators performing inspections at this facility are inspecting all of <br /> the required areas and noting it on the on the reports. <br /> The designated operator failed to check and note all required items on the visual inspection reports.The incorrect and <br /> missing information included the following from the 12/24/18, 3/12/19,4/10/19, and 5/9/19 inspection reports: <br /> -Section VI was left blank. <br /> -The question regarding UDC sensor locations was left blank. <br /> -The report incorrectly states all alarms were responded to by a service technician. <br /> During the visual inspection,the designated operator shall check that all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designated operators <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> FA0003847 PR0231289 SCO01 07/02/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.