Laserfiche WebLink
SAN <br /> J D �� I Environmental Health Department <br /> COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MV TRANSPORTATION#9 1 1250 S WILSON WAY, STOCKTON September 05, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> One container of used oil filters had an accumulation start date of 6/13/17 and another container of used oil filters <br /> was missing an accumulation start date. <br /> All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition (contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all containers are marked with all the required information. <br /> Corrected during inspection. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by October 5, 2018. <br /> Please be aware as of January 1, 2013, all businesses are required to submit all hazardous materials <br /> information online to the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov. Be <br /> sure to include your hazardous waste activity in the Businesses Activities section in CERS in addition to any <br /> other relevant activities and required fields. <br /> Waste types observed: used oil, used antifreeze, aerosol cans, used oil filters, oily absorbent, batteries, <br /> universal wastes- lamps, parts washer waste. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: September 05, 2018 Inspector: Inspector Phone: <br /> #10(QPrinted Name and Title: TRICIA DAI, EHS Trainee (209)468-0331 <br /> Harol Allan, Fleet Maintenance Manager <br /> FA0010836 PR0514432 SCO01 09/05/2018 <br /> EHD 22-01 Rev.10/31/2017 Page 5 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />