CA GREEN CODE REQUIREMENTS ,
<br /> 1. PER CALGREEN SECTION 5.303.2, PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN
<br /> IN TABLE 5.303.2.3. EXCEPTION: BUILDING THAT DEMONSTRATE 20% OVERALL WATER USE REDUCTION. IN THIS
<br /> CASE, A CALCULATION DEMONSTRATING A 2% REDUCTION IN THE BUILDING 'WATER USE BASELINE," AS
<br /> ESTABLISHED IN TABLE 5.303.3 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATIONS TO
<br /> THE BUILDING.
<br /> MAXIMUM FIXTURE FLOW RATES:
<br /> FIXTURE TYPE MAXIMUM FLOW RATE
<br /> LAVATORY FAUCETS-NONRESIDENTIAL 0.5 GPM @ 60 PSI
<br /> KITCHEN FAUCETS 1.8 GPM ® 60 PSI z
<br /> METERING FAUCETS 0.25 GALLONS/CYCLE o
<br /> WATER CLOSETS 1.28 GALLONS/FLUSH
<br /> URINALS 0.5 GALLONS/FLUSH
<br /> w
<br /> 2. PER CALGREEN SECTION 5.303.3.1, THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT 0
<br /> EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE
<br /> CRITERIA OF THE US EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE
<br /> FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO
<br /> REDUCES FLUSHES AND ONE FULL FLUSH.
<br /> 3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE
<br /> DEPOSITING, STORAGE, AND COLLECTION OF NONHAZARDOUS MATERIALS FOR RECYCLING. PER SECTION
<br /> 5.410.1.1 ANY ADDITION OR ALTERATION RESULTING IN LESS THAN A 30% INCREASE IN THE TENANT SPACE
<br /> FLOOR AREA IS EXEMPT FROM THIS REQUIREMENT.
<br /> 4. PER CALGREEN SECTION 5.504.3, AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
<br /> CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL
<br /> DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, w
<br /> SHEET METAL, OR OTHER APPROVED METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH , Q
<br /> MAY ENTER THE SYSTEM. o
<br /> 5. PER CALGREEN SECTION 5.504.4.1, ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS,
<br /> SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH TABLE 5.504.4.1 AND 5.504.4.2. I w
<br /> o'
<br /> SEALANT VOC LIMIT: ARCHITECT OF RECORD:
<br /> ARCHITECTURAL 250
<br /> MARINE DECK 760 ��SEo aRcti/T
<br /> NONMEMBRANE ROOF 300 / CRAIG S. fir,_
<br /> ROADWAY 250 BLUMM -
<br /> SINGLE-PLY ROOF MEMBRANE 450 * N0. C-31661
<br /> OTHER 420 REN,3/31/2021
<br /> 6. PER CALGREEN SECTION 5.504.4.3, ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE �G �y
<br /> 5.504.4.3. y� bC �G
<br /> VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS: 09/13/2019
<br /> INDOOR CARPET ADHESIVES 50 yr =
<br /> CARPET PAD ADHESIVES 50 O
<br /> OUTDOOR CARPET ADHESIVES 150
<br /> WOOD FLOORING ADHESIVES 100 �■
<br /> RUBBER FLOOR ADHESIVES 60
<br /> SUBFLOOR ADHESIVES 50
<br /> CERAMIC TILE ADHESIVES 65
<br /> VCT AND ASPHALT TILE ADHESIVES 50
<br /> DRYWALL AND PANEL ADHESIVES 50
<br /> COVE BASE ADHESIVES 50 �.
<br /> MULTIPURPOSE CONSTRUCTION ADHESIVES 70 W
<br /> STRUCTURAL GLAZING ADHESIVES 100 m
<br /> SINGLE-PLY ROOF MEMBRANE ADHESIVES 250a °'
<br /> OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 O
<br /> SPECIALTY APPLICATIONS PVC WELDING 510N
<br /> w o`�? 3
<br /> CPVC WELDING 490 Of o 3
<br /> ABS WELDING 325
<br /> PLASTIC CEMENT WELDING 250 0 ° s w
<br /> ADHESIVE PRIMER FOR PLASTIC 550 °
<br /> O L 7 ° N
<br /> CONTACT ADHESIVE 80 a c' o0° g `o
<br /> SPECIAL PURPOSE CONTACT ADHESIVE 250 oo
<br /> J a eaai
<br /> U � �o
<br /> STRUCTURAL WOOD MEMBER ADHESIVE 140 oaa;
<br /> TOP AND TRIM ADHESIVE 250 J a 0 O N °O U d p
<br /> TO:
<br /> N N N C
<br /> SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 0 .� ° a 0 E �
<br /> N N aN
<br /> PLASTIC FOAMS 50 o . N�, e
<br /> POROUS MATERIAL (EXCEPT WOOD) 50 p, aCi � E- o 'o
<br /> WOOD 30 0 � :"-r-
<br /> C + U+ C
<br /> FIBERGLASS 80 0 = c°� ° a o C °'
<br /> N p U Op C O
<br /> 7. PER CALGREEN SECTION 5.504.4.3.2, VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED .� �' p °' a °
<br /> cc« m
<br /> AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE o c U'E o o
<br /> FOLLOWING: ° ° ° 0 °t °
<br /> 1. MANUFACTURER'S PRODUCT SPECIFICATION M ° _j `-
<br /> 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS - d 2' °
<br /> ? NFo ° C
<br /> O CL L4 UO
<br /> N OU C N O pl
<br /> co.�L w p V C
<br /> 8. PER CALGREEN SECTION 5.504.4.6, RESILIENT FLOORING SYSTEMS SHALL COMPLY WITH THE VOC-EMISSION v.� -
<br /> p ° N
<br /> o �, �
<br /> LIMITS DEFINED IN THE 2012 CHPS CRITERIA AND LISTEN ON ITS HIGH PERFORMANCE PRODUCTS DATABASE, `v
<br /> PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGAURD CHILDREN & SCHOOLS V o 0- o
<br /> PROGRAM, CERTIFIED UNDER THE FLOORSCORE PROGRAM OF THE RESILIENT FLOOR COVERING INSTITUTE, OR �'��`°:5° c a'
<br /> SHALL MEET CALIFORNIA DEPARTMENT OF PUBLIC HEALTH 2010 SPECIFICATION. 0 0 3 `o o'o o
<br /> tf Q) C
<br /> 9. PER CALGREEN SECTION 5.508.1, RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE co o t
<br /> NONHAZARDOUS CONSTRUCTION OR DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2, OR w - o o r °t
<br /> H a3w C_ 0):0
<br /> 5.408.1.3 OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS 0-
<br /> MORE STRINGENT. z w
<br /> Q
<br /> rn r`
<br /> Q
<br /> m Ow U c0
<br /> p � D p w
<br /> 10. PER CALGREEN SECTION 5.504.1.3, TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM °' o w oN o o N N o cfl
<br /> SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR Y N ui Q `" a N
<br /> AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL �' z > o
<br /> AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN z
<br /> AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE O cj
<br /> 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE
<br /> ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING
<br /> ALTERATION AT THE CONCLUSION OF CONSTRUCTION. Q
<br /> U
<br /> Z
<br /> 11. PER CALGREEN SECTION 5.504.3, COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL o
<br /> EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
<br /> CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT
<br /> AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC,
<br /> SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF
<br /> DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM.
<br /> 12. PER CALGREEN SECTION 5.504.7, ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR Q
<br /> AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR zo
<br /> INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR 0 CD a Z
<br /> REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY 0 z w
<br /> AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS 0 V, a
<br /> OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR _ju F
<br /> POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. O w o a
<br /> Li m w D--
<br /> ~ z o
<br /> 0 CD J co
<br /> z M
<br /> Z w
<br /> Q
<br /> pU z
<br /> C7� _ w w O 00
<br /> w D
<br /> X w
<br /> N W O (n O
<br /> LO GN1 . 1
<br /> �' GENERAL NOTES