Laserfiche WebLink
CA GREEN CODE REQUIREMENTS , <br /> 1. PER CALGREEN SECTION 5.303.2, PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN <br /> IN TABLE 5.303.2.3. EXCEPTION: BUILDING THAT DEMONSTRATE 20% OVERALL WATER USE REDUCTION. IN THIS <br /> CASE, A CALCULATION DEMONSTRATING A 2% REDUCTION IN THE BUILDING 'WATER USE BASELINE," AS <br /> ESTABLISHED IN TABLE 5.303.3 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATIONS TO <br /> THE BUILDING. <br /> MAXIMUM FIXTURE FLOW RATES: <br /> FIXTURE TYPE MAXIMUM FLOW RATE <br /> LAVATORY FAUCETS-NONRESIDENTIAL 0.5 GPM @ 60 PSI <br /> KITCHEN FAUCETS 1.8 GPM ® 60 PSI z <br /> METERING FAUCETS 0.25 GALLONS/CYCLE o <br /> WATER CLOSETS 1.28 GALLONS/FLUSH <br /> URINALS 0.5 GALLONS/FLUSH <br /> w <br /> 2. PER CALGREEN SECTION 5.303.3.1, THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT 0 <br /> EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE <br /> CRITERIA OF THE US EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE <br /> FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO <br /> REDUCES FLUSHES AND ONE FULL FLUSH. <br /> 3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE <br /> DEPOSITING, STORAGE, AND COLLECTION OF NONHAZARDOUS MATERIALS FOR RECYCLING. PER SECTION <br /> 5.410.1.1 ANY ADDITION OR ALTERATION RESULTING IN LESS THAN A 30% INCREASE IN THE TENANT SPACE <br /> FLOOR AREA IS EXEMPT FROM THIS REQUIREMENT. <br /> 4. PER CALGREEN SECTION 5.504.3, AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE <br /> CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL <br /> DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, w <br /> SHEET METAL, OR OTHER APPROVED METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH , Q <br /> MAY ENTER THE SYSTEM. o <br /> 5. PER CALGREEN SECTION 5.504.4.1, ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, <br /> SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH TABLE 5.504.4.1 AND 5.504.4.2. I w <br /> o' <br /> SEALANT VOC LIMIT: ARCHITECT OF RECORD: <br /> ARCHITECTURAL 250 <br /> MARINE DECK 760 ��SEo aRcti/T <br /> NONMEMBRANE ROOF 300 / CRAIG S. fir,_ <br /> ROADWAY 250 BLUMM - <br /> SINGLE-PLY ROOF MEMBRANE 450 * N0. C-31661 <br /> OTHER 420 REN,3/31/2021 <br /> 6. PER CALGREEN SECTION 5.504.4.3, ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE �G �y <br /> 5.504.4.3. y� bC �G <br /> VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS: 09/13/2019 <br /> INDOOR CARPET ADHESIVES 50 yr = <br /> CARPET PAD ADHESIVES 50 O <br /> OUTDOOR CARPET ADHESIVES 150 <br /> WOOD FLOORING ADHESIVES 100 �■ <br /> RUBBER FLOOR ADHESIVES 60 <br /> SUBFLOOR ADHESIVES 50 <br /> CERAMIC TILE ADHESIVES 65 <br /> VCT AND ASPHALT TILE ADHESIVES 50 <br /> DRYWALL AND PANEL ADHESIVES 50 <br /> COVE BASE ADHESIVES 50 �. <br /> MULTIPURPOSE CONSTRUCTION ADHESIVES 70 W <br /> STRUCTURAL GLAZING ADHESIVES 100 m <br /> SINGLE-PLY ROOF MEMBRANE ADHESIVES 250a °' <br /> OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 O <br /> SPECIALTY APPLICATIONS PVC WELDING 510N <br /> w o`�? 3 <br /> CPVC WELDING 490 Of o 3 <br /> ABS WELDING 325 <br /> PLASTIC CEMENT WELDING 250 0 ° s w <br /> ADHESIVE PRIMER FOR PLASTIC 550 ° <br /> O L 7 ° N <br /> CONTACT ADHESIVE 80 a c' o0° g `o <br /> SPECIAL PURPOSE CONTACT ADHESIVE 250 oo <br /> J a eaai <br /> U � �o <br /> STRUCTURAL WOOD MEMBER ADHESIVE 140 oaa; <br /> TOP AND TRIM ADHESIVE 250 J a 0 O N °O U d p <br /> TO: <br /> N N N C <br /> SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 0 .� ° a 0 E � <br /> N N aN <br /> PLASTIC FOAMS 50 o . N�, e <br /> POROUS MATERIAL (EXCEPT WOOD) 50 p, aCi � E- o 'o <br /> WOOD 30 0 � :"-r- <br /> C + U+ C <br /> FIBERGLASS 80 0 = c°� ° a o C °' <br /> N p U Op C O <br /> 7. PER CALGREEN SECTION 5.504.4.3.2, VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED .� �' p °' a ° <br /> cc« m <br /> AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE o c U'E o o <br /> FOLLOWING: ° ° ° 0 °t ° <br /> 1. MANUFACTURER'S PRODUCT SPECIFICATION M ° _j `- <br /> 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS - d 2' ° <br /> ? NFo ° C <br /> O CL L4 UO <br /> N OU C N O pl <br /> co.�L w p V C <br /> 8. PER CALGREEN SECTION 5.504.4.6, RESILIENT FLOORING SYSTEMS SHALL COMPLY WITH THE VOC-EMISSION v.� - <br /> p ° N <br /> o �, � <br /> LIMITS DEFINED IN THE 2012 CHPS CRITERIA AND LISTEN ON ITS HIGH PERFORMANCE PRODUCTS DATABASE, `v <br /> PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGAURD CHILDREN & SCHOOLS V o 0- o <br /> PROGRAM, CERTIFIED UNDER THE FLOORSCORE PROGRAM OF THE RESILIENT FLOOR COVERING INSTITUTE, OR �'��`°:5° c a' <br /> SHALL MEET CALIFORNIA DEPARTMENT OF PUBLIC HEALTH 2010 SPECIFICATION. 0 0 3 `o o'o o <br /> tf Q) C <br /> 9. PER CALGREEN SECTION 5.508.1, RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE co o t <br /> NONHAZARDOUS CONSTRUCTION OR DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2, OR w - o o r °t <br /> H a3w C_ 0):0 <br /> 5.408.1.3 OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS 0- <br /> MORE STRINGENT. z w <br /> Q <br /> rn r` <br /> Q <br /> m Ow U c0 <br /> p � D p w <br /> 10. PER CALGREEN SECTION 5.504.1.3, TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM °' o w oN o o N N o cfl <br /> SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR Y N ui Q `" a N <br /> AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL �' z > o <br /> AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN z <br /> AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE O cj <br /> 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE <br /> ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING <br /> ALTERATION AT THE CONCLUSION OF CONSTRUCTION. Q <br /> U <br /> Z <br /> 11. PER CALGREEN SECTION 5.504.3, COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL o <br /> EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE <br /> CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT <br /> AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, <br /> SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF <br /> DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. <br /> 12. PER CALGREEN SECTION 5.504.7, ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR Q <br /> AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR zo <br /> INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR 0 CD a Z <br /> REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY 0 z w <br /> AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS 0 V, a <br /> OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR _ju F <br /> POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. O w o a <br /> Li m w D-- <br /> ~ z o <br /> 0 CD J co <br /> z M <br /> Z w <br /> Q <br /> pU z <br /> C7� _ w w O 00 <br /> w D <br /> X w <br /> N W O (n O <br /> LO GN1 . 1 <br /> �' GENERAL NOTES <br />