Laserfiche WebLink
Master Builders Solutions by BASF <br /> www.master-builders-soluflons.bast.us <br /> Yield <br /> LINEAR FEET PER GALLON' <br /> JOINT DEPTH, JOINT WIDTH pNCHES) <br /> pNCHES) t/a %8 %2 5/a 3/a '/e 1 1 Yz 2 3 <br /> '�4 308 205 154 122 — — — — — — <br /> 1/8 — — — 82 68 58 51 — — — <br /> 1�2 — — — — 51 44 38 26 19 12 <br /> METERS PER LITER <br /> JOINT DEPTH, JOINT WIDTH(MM) <br /> (MM) 6 10 13 16 19 22 25 38 50 75 <br /> 6 24.8 16.5 12.4 9.8 — — — — — — <br /> 10 — — — 6.6 5.5 4.7 4.1 — — — <br /> 13 — — — — 4.1 3.5 3.0 2.2 1.5 0.7 <br /> HOW TO APPLY SURFACE PREPARATION PRIMING <br /> JOINT PREPARATION Substrates must be structurally sound,fully 1.MasterSeal NP 1 is considered a non-priming <br /> 1.The product may be used in sealant joints cured,dry,and clean.Substrates should always sealant,but special circumstances or substrates <br /> designed in accordance with SWR Institute's be free of the following:dirt,loose particles, may require a primer.it is the user's responsibility <br /> Sealants-The Professional's Guide. oil,grease,asphalt,tar,paint,wax,rust, to check the adhesion of the cured sealant on <br /> 2.In optimal conditions,the depth of the sealant waterproofing or curing and parting compounds, typical test joints at the project site before and <br /> should be h the width of the joint.The sealant membrane materials and sealant residue. during application.Refer to product data sheet <br /> joint depth(measured at the center)should CONCRETE,STONE AND OTHER MASONRY on MasterSeal P 173 or MasterSeal P 176,and <br /> always fall between the maximum depth of h" consult Technical Service for additional information. <br /> and the minimum depth of 1/ to expos".Refer to Table 1, Clean expose a sound surface free of contamination grinding,sandblasting or wire brushing 2 For immersion applications,MasterSeal P 173 <br /> 3.In deep joints,the sealant depth must be must be used. <br /> controlled by closed cell backer rod or soft and laitance. 3,Apply primer full strength with a brush or clean <br /> backer rod.Where the joint depth does not WOOD cloth.A light,uniform coating is sufficient for <br /> permit the use of backer rod,a bond breaker New and weathered wood must be clean,dry most surfaces.Porous surfaces require more <br /> (polyethylene strip)must be used to prevent and sound.Scrape away loose paint to bare primer;however,do not over-apply. <br /> three-point bonding. wood.Any coatings on wood must be tested to 4.Allow primer to dry before applying MasterSeal NP <br /> 45o maintain the recommended sealant depth, verify adhesion of sealant or to determine an 1.Depending on temperature and humidity,primer <br /> install backer rod by compressing and rolling appropriate primer. will be tack-free in 15-120 minutes.Priming and <br /> it into the joint channel without stretching it METAL sealing must be done on the same day. <br /> lengthwise.Closed cell backer rod should be Remove scale,rust and loose coatings from <br /> about Y8"(3 mm)larger in diameter than the APPLICATION <br /> metal to expose a bright white surface.Any <br /> width of the joint to allow for compression.Soft coatings on metal must be tested to verity 1.MasterSeal NP 1 comes ready to use.Apply <br /> backer rod should be approximately 25%larger adhesion n sealant or to determine an using professional grade caulking gun.Do <br /> In diameter than the joint width.The sealant appropriate primer. not open cartridges,ProPaks or pails until <br /> does not adhere to it,and no separate bond preparatory work has been completed. <br /> breaker is required.Do not prime or puncture 2.Fill joints from the deepest point to the surface by <br /> the backer-rod. holding an appropriately sized nozzle against <br /> the back of the joint. <br />