Laserfiche WebLink
SAN J O A R N Environmental Health Department <br /> i , �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 76 FUEL ISLAND&CARWASH 141 E HARNEY LN, LODI July 07, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> OBSERVATION: The monitoring plans for all tanks are not current and/or not approved by the EHD. <br /> -The monitoring plans incorrectly indicate"no"for training. <br /> -The monitoring plans do not indicate the sensors performing monitoring. <br /> -The monitoring plans are missing information under"Name of Second Person Having Responsibility." <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d), 2641(h), 2711(a) Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> OBSERVATION:A UST Monitoring Site Plan was not submitted. <br /> REGULATION GUIDANCE:A site plan must be submitted identifying the locations where monitoring will be <br /> performed. The site plan must show the general layout of tanks and piping and clearly identify locations of the <br /> following equipment, if installed: 1)monitoring system control panels; 2)in-tank liquid level probes (if used for leak <br /> detection); 3)devices monitoring tank annular spaces or vault;4)devices monitoring product piping; 5)devices <br /> monitoring fill piping; 6)devices monitoring vent piping; 7)devices monitoring vapor recovery piping; 8)devices <br /> monitoring vent/transition sumps; 9)devices monitoring under-dispenser containment; 10)line leak detectors; and <br /> 11)devices monitoring any other secondary containment areas. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 115 CCR 2715(a)(1)(B), 2715(a)(3)"Designated Underground Storage Tank Operator Identification Form"not submitted <br /> within 30 days. <br /> OBSERVATION: The Designated Underground Storage Tank Operator Identification Form was not found in CERS. <br /> REGULATION GUIDANCE: This form must be uploaded to the California Environmental Reporting System (CERS). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov and upload the Underground Storage Tank Statement of Understanding and Compliance <br /> Form for this facility. <br /> This is a minor violation. <br /> FA0024750 PR0543574 SCO01 07/07/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 5 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />