Laserfiche WebLink
QUID <br /> ,. <br /> 2 S A N J 0 A Q U I N Environmental Health Department <br /> COUNTY <br /> Ali Linda Turkatte , REHS , Director <br /> cq14. ,FoRk Greatness grows here . Kasey Foley, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> July 10 , 2019 Muniappa Naidu , REHS <br /> Megan Mitchell <br /> Elite IV Contractors <br /> 2535 Wigwam Dr , <br /> Stockton , CA 95205 <br /> Re : E F Kludt & Sons Inc SR0080231 <br /> 1126 E . Pine St . , Lodi , CA 95240 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to replace the direct- bury diesel spill container and diesel drop tube on the <br /> underground storage tank ( UST) system at the above noted address . The permit has been approved <br /> with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Shewit Woldearegay at (209) 468 - 0216 to arrange the following inspection <br /> appointments ( a 48- hour notice is required for inspection appointments ) . Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval . <br /> a . Corrosion protection : Verify corrosion protection for direct bury spill bucket prior to <br /> backfilling . <br /> b . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) . Proper drainage must also be verified . <br /> c . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut <br /> off. Verification of ball floats absent or located at a level that will not interfere with drop tube <br /> functionality . <br /> d . Since concrete will be broken near the diesel tank , a secondary containment test must be <br /> performed on the diesel tank once concrete is poured in accordance with the <br /> manufacturer' s guidelines . <br /> Please be aware that the facility cannot receive fuel in the diesel tank prior to the EHD <br /> inspection and approval . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board (may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468 -3420 F 209 464 - 0138 1 www . sjcehd . com <br />