Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GOLD COAST LIFT TRUCKS INC t335 E WETMORE ST, MANTECA September 03. 2019 <br /> SUMMARY OF.VIOLATIONS - <br /> (CLASS I,CLASS d,or MINOR-Nodes to Comply) <br /> Itom# Remarks <br /> 303 CCR 66262 34(d)(2)Failed to maintain all communication or alarm systems,spill control,or decontamination <br /> equipment. <br /> OBSERVATION The following were observed in the hazardous waste storage area. <br /> •Secondary containment for used oil and waste antifreeze observed with approximately 2 inches of oil accumulating <br /> Inside <br /> -Secondary containment for used oil and used oil metal Filters observed with approximately 2 Inches of oil <br /> accumulating Inside <br /> REGULATION GUIDANCE All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment,and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in lime of emergency <br /> CORRECTIVE ACTION: Bring the two secondary containment for the used oil,waste antifreeze and used metal oil <br /> fitters into proper working order by repair, replacement or testing. Provide a corrective action statement to the San <br /> Joaquin County Environmental Health Department within 30 days <br /> This is a minor violation. <br /> 304 CCR 66262.34(d)(2)Failed to maintain adequate aisle space for unobstructed response to emergencies <br /> OBSERVATION: The following area does not have adequate aisle space: The hazardous waste storage area for <br /> waste antifreeze and used metal ail Filters were obstructed by propane tanks and other miscellaneous containers. <br /> REGULATION GUIDANCE:The owner or operator shall maintain aisle space to allow the unobstructed movement <br /> of personnel, fire protection equipment,spill control equipment,and decontamination equipment to any area of <br /> facility operation in an emergency,unless it can be demonstrated to the Department that aisle space is not needed <br /> for any of these purposes <br /> CORRECTIVE ACTION Immediately maintain aisle space to allow the unobstructed movement of personnel,fire <br /> protection,spill control equipment,and decontamination equipment to any area of facility operation in an <br /> emergency. Provide a corrective action statement to the San Joaquin County Environmental Health Department <br /> within 30 days <br /> This is a minor violation. <br /> FA0 IMM9 PRO544M SC001 0910321019 <br /> EHo 22.01 Ray g20r20l9 Page 5 of 8 small Quarnity Hazardous waste Generator QIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-34201 F 209 464-0138 1 www sicehb com <br />