S0 JOA U 1 Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FOOD MART GASOLINE* 2185 E FREMONT ST, STOCKTON September 02, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 124 CCR 2637.2(d&e), 2665(a&b)"Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days <br /> of inspection. <br /> OBSERVATION: Overfill prevention equipment inspection was performed on 9/3/19 and a test report was submitted <br /> on 10/15/19, one month late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are <br /> performed in a timely manner. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br /> reports.The incorrect and missing information included the following from the inspection reports: <br /> -The alarm history printout attached to the report did not include T alarms(overfill) <br /> REGULATION GUIDANCE: During the visual inspection,the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> OBSERVATION: The designated operator failed to check and note the correct test dates for the overfill prevention <br /> inspection on the designated operator inspection reports. Three different dates were used. This testing was <br /> conducted on 9/3/19. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a minor violation. <br /> FA0003284 PR0231118 SCO01 09/02/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />