, <br /> ri <br /> f <br /> OPW Installation , Operation , and Maintenance Manual , Page 74 Executive Order VR- 102-0 <br /> k <br /> ®Registered T. M. Owens Corning Fiberglass Corporation ASSEMBLY INSTRUCTIONS F ' <br /> Tape measure IMPORTANT : Each of the numbered steps in the instal € , <br /> .� lation instructions are designed as a CHECK LIST to en - : <br /> sure proper installation and trouble free operation of the <br /> OPW 61 SO Overfill Prevention Valve , <br /> �f <br /> Read and follow these steps carefully , checking them off <br /> as you proceed . <br /> Riser <br /> Pipe Figure numbers correspond to step numbers for easy <br /> with <br /> Face To Tank ( ) reference . <br /> peal Adaptor Top To <br /> ( I . ) Tank STEP 1 : MEASURE (i <br /> Bot om Install the OPW Face Seal Adaptorand the OPW Thread <br /> on Spill Container on the Fill Riser ( Refer to the Installa - i <br /> tion Instructions Supplied with the Spill Container) . In - <br /> sert a tape measure through the riser pipe and hook it <br /> under the inside of the tank in the lengthwise direction . hi <br /> EXAMPLE <br /> Measure the distance from the top of the Face Seal <br /> 1 ) For an Owens- Corning Model G3 Fiberglass® Tank Adaptor threads inside the base of the spill container <br /> Calibration Chart : bucket just below the drain valve outlet window to the <br /> Tank Capacity 10 ,000 gal . , nominal 9 ,403 gal . inside , top lip of the storage tank ( Dim . "A" ) <br /> NOTE : Use actual capacity only ( See Figure 1 & 1A) . <br /> 2 ) 95 % of actual tank capacity = 0 . 95 x 9403 gal . = The top flange on the 61 SO will rest on the Face Seal <br /> 8933 gal . Adaptor just below the drain valve outlet , and be locked <br /> 3) The closest numberwhich is less than 8933 gal . Is in place between the Face Seal Adaptor and the 4 ' <br /> 8910 gal . Choosing the closest number less than nipple that is installed in the spill container with the t <br /> 95 % of actual capacity ensures that the initial Jack Screw Kit ( See Figure 1A) . ( For riser pipe configu t, <br /> shutoff will occur when the tank is no more than rations other than that shown , consult installation l: <br /> means to measure Di <br /> 95 % full . drawings or use other necessary Ei <br /> 1 <br /> 4 ) The calibration chart reading of 8910 gal , corre- mension " A" ) . ; <br /> sponds to a dipstick measurement of 82 . Using a tape measure , measure the distance from the top <br /> 5 ) Dipstick number ( X ) = 82" of the Face Seal Adaptor in the spill container to the <br /> Tank diameter (Y ) = 92" bottom of the tank ( Dim . "B ") . <br /> (Y ) - ( X) _ (Z) ( 92 " , 2 = 10 IMPORTANT : Inspect the riser pipe for any foreign ma- <br /> (Z ) = 10 terial . Over spray from tank relining or any internal burrs <br /> 6) (Z) - 2 - C ( 10" - 2" = 8") inside of pipe must be removed prior to installation . <br /> C = 8" Failure to have an unobstructed riser pipe may prevent <br /> proper installation and operation of the valve . The 61 SO <br /> 7 ) Is 8" less than 6- 1 /2" 0is designed for installation into schedule 40 riser pipes . <br /> 51 <br /> The 61 SO cannot be installed into schedule 80 riser <br /> NO Measure the distance from the top of the FSA- pipes . <br /> 400 Face Seal Adaptor installed on the riser pipe STEP 2 : MARKTHETUBE <br /> to the inside , top lip of the storage tank and Use the result from Step 1 and HOW TO LOCATE THE i <br /> obtain measurement ( A) . POSITION OFTHE 61 SO AT 95% TANK CAPACITYto <br /> mark the upper tube . Measure the distance from the <br /> Upper tube length = C + (A) point where the upper tube and valve body meet . For <br /> " C " measurements greater than 6 - 112" use tape <br /> measure to mark the calculated upper tube length onto <br /> the upper tube . <br /> I � <br />€ i <br /> i <br />