My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
816
>
2300 - Underground Storage Tank Program
>
PR0231470
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2021 3:52:48 PM
Creation date
9/3/2020 1:17:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231470
PE
2361
FACILITY_ID
FA0003911
FACILITY_NAME
VAN DE POL ENTERPRISES INC
STREET_NUMBER
816
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102010
CURRENT_STATUS
01
SITE_LOCATION
816 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUNDSTORAGETANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑Installation Inspection ❑Repair Inspection ❑x 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181513 1/7/19 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> RIPON CFN <br /> Business Site Address City ZIP Code <br /> 816 S FRONTAGE RD RIPON 95366 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Edward Stearns 1 (209) 744-0112 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 14-1760 Ex. 09/30/2020 8883080-UT 11/9/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> FF- EBW, Phil-Tite &EVR Phase 1 1009893708 Ex 11/29/2020 OPW 104-635 Ex 3-14-2020 <br /> Emco 3205 Ex. 11/16/2020 ATG:VR A31048 Ex.8/9/19 Incon 1009893708 11/30/2020 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method 0 Manufacturer Guidelines(Specify): <br /> Used: VR AV- Probes <br /> ❑Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages 5 <br /> TANK ID:(By tank number,storedproduct,etc.) 87 91 DIESEL <br /> What is the tank inside diameter?(Inches) 110.50 110.50 111.00 <br /> Is the fill piping secondarily contained? 0 Yes ❑No 0 Yes ❑No 0 Yes ❑No ❑Yes ❑ No <br /> Is the vent piping secondarily contained? ❑Yes 0 No ❑Yes 0 No ❑Yes 0 No ❑Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) V/R V/R V/R <br /> PROBES PROBES PROBES <br /> What is the overfill prevention equipment response ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> 0 AN Alarm 0 A/V Alarm 0 AN Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? HI Yes ❑No 0 Yes ❑No 0 Yes ❑No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 93 931/4 931/4 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 90 90 90 <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes ❑p Yes ❑Yes <br /> to respond when the substance reaches the <br /> El level? No(Specify in V) No(Specify in V.) El No(Specify in V) No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑x Pass ❑Fail 0 Pass ❑ Fail 0 Pass ❑Fail -[:] Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments ma/so tYe provided here <br /> COULD NOT REMOVE BALL FLOATS TO VERIFY L .�'j v # <br /> OCT 2 2 2019 <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordant talif rCMITA Af,_T",Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate.;E <br /> UST Service Technician Signature ✓( <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=CaGfomia Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AA/=Audible and Visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.