My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082410
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
13550
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0082410
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:48:04 PM
Creation date
9/3/2020 2:37:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0082410
PE
4231
FACILITY_NAME
13550 HWY 12
STREET_NUMBER
13550
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05502002
ENTERED_DATE
7/31/2020 12:00:00 AM
SITE_LOCATION
13550 W HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
K K JE L D S E N Stephen K.Sinnock.P.E. <br /> S S I N N O C K Christopher H.Neudeck.P.E. <br /> Neal T.Colwell,P.E. <br /> N N E U D E C K Barry O'Regan.P.E. <br /> inn. CIVIL ENGINEERS 8 LAND SURVEYORS <br /> 2414-0010 <br /> 01-001 <br /> February H,2020 <br /> Mr. Michael Kith <br /> mkithksicehd.com � ��� <br /> REHS Program Coordinator <br /> Environmental Health Department <br /> San Joaquin County FEB ? Q 2020 <br /> 1868 East Hazelton Avenue <br /> Stockton,CA 95205 ENVIRONMENTAL HEALTH <br /> Re: Grindstone Joe's Wastewater Holding Tank—SJC EHD Permitting Review PERM IT/SERVICES <br /> Dear Mr. Kith, <br /> This letter,written on behalf of the Grindstone Joe Association(Association), is intended to provide additional <br /> detail as requested by the February 5,2020 email correspondence with the San Joaquin County Environmental <br /> Health Department(SJC EHD). This correspondence is provided as attachment to this letter. The following <br /> addresses the information requested by the SJC EHD by each item. <br /> Item 1 states that"a holding tank system may be approved for existing developments on parcels that can <br /> no longer support an onsite wastewater treatment system (OWTS)disposal field, and can only be <br /> approved if the existing development has an existing permitted OWTS. According to EHD records,there <br /> are two OWTS and one holding tank on the parcel." <br /> We are providing an engineered design of a holding tank to replace existing holding tanks that were <br /> identified as not meeting County standards. The Notice and Order to Abate(NAO),Complaint ID: <br /> CO0048503, indicates that an engineer-designed sewage disposal (wastewater holding)system should be <br /> submitted for EHD approval. Since the site has very shallow groundwater and an on-site disposal system <br /> is not appropriate,the submitted engineer-designed wastewater holding tank is intended to replace the <br /> NAO referenced OWTSs and the holding tank at the site. <br /> Item 2 requests that the Association identify the permitted OWTS intended to be replaced on the plans, <br /> and to provide the justification for replacing the septic system with the holding tank. This holding tank is <br /> intended to replace all non-permitted OWTS on the island. This tank is only intended to service the <br /> restroom facilities and deck facilities,not the house boats. All other holding tanks will be removed by the <br /> Association. <br /> Item 3 states that the engineer-designed OWTS must contain all information listed in OWTS Standards <br /> Section 7.1. Since the proposed system,being presented consistent with the NAO, is a wastewater <br /> holding tank system,preparation of design requirements under Section 7.1 of the OWTS Standards are <br /> not applicable nor appropriate to this project. Instead,the holding tank has been designed and submitted <br /> including information required by OWTS Standards Section 10. Additionally,the submitted plans have <br /> been stamped by a civil engineer licensed in the State of California. <br /> Item 4 states that the proposed holding tank shall include information listed in OWTS Standards Section <br /> 10.1 to 10.8. The provided plans have been prepared to conform to OWTS Standards Section 10. <br /> Furthermore,the OWTS Standards Section 10.1 states that holding tanks may be approved for existing <br /> developments on parcels which can no longer support an OWTS disposal field that meets the <br /> requirements of the OWTS Standards, is no longer protective of ground and/or surface waters,or is a <br /> Corporate Office: 711 N Pershing Avenue I Stockton,CA 95203 1 209-946-0268 1 www.ksninc.com <br /> West Sacramento: 1550 Harbor Boulevard.Suite 212 1 West Sacramento,CA 95691 1916-403-5900 <br />
The URL can be used to link to this page
Your browser does not support the video tag.