My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082410
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
13550
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0082410
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:48:04 PM
Creation date
9/3/2020 2:37:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0082410
PE
4231
FACILITY_NAME
13550 HWY 12
STREET_NUMBER
13550
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05502002
ENTERED_DATE
7/31/2020 12:00:00 AM
SITE_LOCATION
13550 W HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.3.5.2.SPACING IN STABLE IN-SITU (NATIVE) 1.3.5.2.3.If two or more tanks are installed in the same hole and <br /> SOIL CONDITIONS deadmen are used,the space between the tanks must be equal to or <br /> 1.3.5.2.1.The minimum spacing between the sidewall or endcap greaterthan two times the width of the deadman or deadmen required <br /> of the tank and the side of the excavation must be 18 inches[46 cm]. between the tanks.See Figure 1-2. <br /> The space between tanks using our deadmen is typically 36 inches <br /> See Figure 13. [91 cm]for 10-foot-and 12-foot-diameter tanks,and 24 inches[60 cm] <br /> NOTE:All measurements from the tank sidewalls are to be taken for tanks smaller than 10 feet in diameter. <br /> from the outside diameter of the tank ribs. 1.3.5.3.SPACING IN UNSTABLE IN-SITU(NATIVE) <br /> 1.3.5.2.2.If two or more tanks are installed in the same hole,allow SOIL CONDITIONS <br /> for at least 18 inches[46 cm]between the tanks.In Canada,the National 1.3.5.3.1.We recommend that the tank owner seek the advice of <br /> Fire Code of Canada requires 24 inches[60 cm]between a fuel tank and a local foundation professional engineer if the in-situ soil is soft or <br /> another tank or structure.See Figure 1-3. inherently unstable(for example,peat,quick-sand,muck,landfill,soft <br /> Figure 1-3 or highly expansive clay,underground stream,etc.),as further described <br /> in point 1.3.5.3.2. <br /> III I 1.3.5.3.2.The excavation mustallow a minimum space <br /> equal to 112 the diameter of the tank between <br /> Ell the excavation wall and both the side and the endcap <br /> of the tank to enhance lateral resistance(see Figure 1-3), <br /> IIIII if one of the following criteria is met: <br /> • the soil is cohesive soil that is less than 750 lbs./sq.ft. <br /> IIIII [35.9 kPa]as calculated from an unconfined compression <br /> =18" 18" 18" test OR <br /> IIIII[60 [60 [60 • the soil has an ultimate bearing capacity of less than <br /> IIIII cm] cm] cm] 3,500 lbs./sq.ft.[167.6 kPa] <br /> 1.3.5.3.3.Stabilizing materials,such as a reinforced concrete <br /> IIIII slab,may be required under the tank as a foundation in addition <br /> 18"[60 cm] to the required 12-inch[30-cm]bedding in an excavation where <br /> 18"[60 cm <br /> IIIII ] the bottom is unstable. <br /> IIIII=IIIII-IIIII-IIIII=IIIII-IIIII=IIIII-IIIII-IIIII=IIIII-IIIII-11 <br /> IIIII- Stable Soil =IIIII=IIIII=IIIII-IIIII=IIIII-IIIII 1.3.5.3.4.The spacing between adjacent tanks is to be at least <br /> IIIII-III III-IIIII-IIIII-IIIII—IIIII-IIIII-IIIII-IIIII=IIIII-IIIII-11 18 inches[46 cm].In Canada,the National Fire Code of Canada <br /> requires 24 inches[60 cm]between a fuel tank and another <br /> M 111 tank or structure.See Figure 1-3. <br /> I 1.3.5.3.5.If deadmen are used,follow the spacing <br /> requirements between the tanks given in points 1.3.5.2.2 <br /> IIIII and 1.3.5.2.3. <br /> IIIII 1.3.6.ADDING TANKS AT EXISTING LOCATIONS <br /> IIIII 1.3.6.1.GENERAL <br /> V2Tank 18" 1.3.6.1.1.Additional tanks may be installed at existing locations <br /> IIIII Diameter [60 if proper foundation support exists. <br /> IIIII 1.3.6.1.2.Backfill support around the existing tanks must not <br /> be disturbed. <br /> IIIII 1.3.6.1.3.It is the responsibility of the tank owner to choose <br /> IIIII /zTank �/z Tank the method of installation. <br /> Diameter Diameter 1.3.6.1.4.We recommend that one of the following methods <br /> II III be used. <br /> IIIII-IIIII-IIIII=IIIII-IIIII-IIIII-IIIII-IIIII-IIIII-IIIII-IIIII=11 <br /> IIIII- Unstable Soil wilig 11111M IN11111 111111MI111111 111111 111111M 111111= <br /> II-IIIII <br /> 08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.